journal article·2025-02-05Open access

Frequency Response Extension Method of MET Vector Hydrophone Based on Dynamic Feedback Network

Fang Bian, Ang Li, Hongyuan Yang, Fan Zheng, Dapeng Yang, Huaizhu Zhang, Linhang Zhang, Ruojin Li

Applied Sciences· Volume 15· Issue 3

Abstract

Hydrophone is a key component of marine seismic exploration systems, divided into a scalar hydrophone and vector hydrophone. The electrochemical vector hydrophone has attracted much attention due to its high sensitivity and low-frequency detection capability. With the development of noise reduction technology, high-frequency noise has been effectively suppressed, while low-frequency noise is still difficult to control, which has become a key issue in the monitoring of underwater target radiation noise. The traditional electrochemical vector hydrophone based on the molecular electron transfer (MET) principle is limited in the working bandwidth in the low-frequency band, which affects the detection capability of low-frequency radiation signals from underwater targets. In order to solve this problem, a frequency response extension method of a MET electrochemical vector hydrophone based on dynamic feedback network is proposed. By introducing a dynamic force balance negative feedback system based on a digital signal processor (DSP), the working bandwidth of the hydrophone is extended, and the detection capability of low-frequency signals is enhanced. At the same time, the system has field adjustability and can resist the long-term system frequency characteristic drift. Experimental results show that the proposed method effectively improves the frequency response performance of the electrochemical vector hydrophone, providing a new technical solution for its application in the monitoring of low-frequency radiation noise from underwater targets.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Speech and Audio Processing

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Zhuhai 519000, China

Key Laboratory of Geophysical Exploration Equipment, Ministry of Education, College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130061, China

Funding

Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai)

References (33)

Show source-provided references
1. Earthquake physics and real-time seismology10.1038/nature06585 ↗
2. Measuring Devices Based on Molecular-Electronic Transducers10.1134/S1064226918110025 ↗
3. Evseev, I., Zaitsev, D., and Agafonov, V. (2019). Study of Transfer Characteristics of a Molecular Electronic Sensor for Borehole Surveys at High Temperatures and Pressures. Sensors, 19.10.3390/s19112545 ↗
4. The Temperature Dependence of Amplitude- Frequency Response of the MET Sensor of Linear Motion in a Broad Frequency Range10.1109/JSEN.2019.2927859 ↗
5. Analysis of the effect of vortex reduction structures on submarine tonal noise via frequency-domain method employing thickness noise source10.1016/j.oceaneng.2022.111640 ↗
6. Kim, G., Kim, D., and Roh, Y. (2024). Design of Wideband Flextensional Hydrophone. Sensors, 24.10.3390/s24154941 ↗
7. A vector-hydrophone’s minimal composition for finite estimation-variance in direction-finding near/without a reflecting boundary10.1109/TSP.2007.893950 ↗
8. George, P.G., Rajesh, R., Sreehari, V.C., Vivek, K., Praveen, V.T., and Kumar, S. (2017, January 4–5). Experimental Investigations on Stability and Noise Issues of Michelson Interferometer based Fiber Optic Hydrophones. Proceedings of the 2017 IEEE 3rd International Conference on Sensing, Signal Processing and Security (ICSSS), Chennai, India.10.1109/SSPS.2017.8071582 ↗
9. Miniaturized GaN-Based Optical Hydrophones for Underwater Low-Frequency Acoustic Detection10.1109/LPT.2024.3454151 ↗
10. Design of low frequency hydrophone based on PVDF piezoelectric materials10.4028/www.scientific.net/AMM.513-517.3085 ↗
11. Features and Technology of Piezoelectric Hydrophone10.4028/www.scientific.net/AMR.199-200.1832 ↗
12. A MEMS Based Electrochemical Vibration Sensor for Seismic Motion Monitoring10.1109/JMEMS.2013.2292833 ↗
13. MEMS flexible conformal hydrophone based on heterogeneous integration technology10.1108/SR-01-2024-0032 ↗
14. Yan, H., Xu, T., Wang, P., Zhang, L., Hu, H., and Bai, Y. (2019). MEMS Hydrophone Signal Denoising and Baseline Drift Removal Algorithm Based on Parameter-Optimized Variational Mode Decomposition and Correlation Coefficient. Sensors, 19.10.3390/s19214622 ↗
15. Frequency-Selective Seismic Sensor10.1109/TIM.2011.2169610 ↗
16. A fiber-optic sensor for the ground vibration detection10.1016/j.optcom.2013.05.057 ↗
17. Zaitsev, D., Egor, E., and Shabalina, A. (2018, January 4–6). High resolution miniature MET sensors for healthcare and sport applications. Proceedings of the 2018 12th International Conference on Sensing Technology (ICST), Univ Limerick, Dept Elect & Comp Engn, Limerick, Ireland.10.1109/ICSensT.2018.8603579 ↗
18. Design and Self-Noise of MET Closed-Loop Seismic Accelerometers10.1109/JSEN.2017.2662207 ↗
19. A Molecular-Electronic Hydrophone for Low-Frequency Research of Ambient Noise in the World Ocean10.1134/S1028334X1812022X ↗
20. Egorov, V.E., Shabalina, A.S., Zaytsev, D.L., and Velichko, G. (2019, January 25–27). Low Frequency Hydrophone for Marine Seismic Exploration Systems. Proceedings of the 5th International Conference on Sensors and Electronic Instrumentation Advances (SEIA), Adeje, Spain.
21. Diffusion sensor of mechanical signals: Frequency response at high frequencies10.1023/B:RUEL.0000027625.71991.5e ↗
22. The Electrochemical Seismometer Based on Fine-Tune Sensing Electrodes for Undersea Exploration10.1109/JSEN.2020.2985702 ↗
23. Krishtop, V.T., Zhevnenko, D.A., Kokhanovsky, V.S., Dudkin, V.P., Zlobin, A.S., Belyaev, A.Y., and Krishtop, V.G. (2019, January 1–5). High-sensitive ultra-low frequency hydrophone. Proceedings of the International Conference on Micro- and Nano-Electronics, Zvenigorod, Russia.10.1117/12.2522033 ↗
24. Zaitsev, D., Egorov, I., and Agafonov, V. (2022). A Comparative Study of Aqueous and Non-Aqueous Solvents to Be Used in Low-Temperature Serial Molecular-Electronic Sensors. Chemosensors, 10.10.3390/chemosensors10030111 ↗
25. Yang, D., Wang, X., Sun, J., Chen, H., Ju, C., Lin, T., Tian, B., and Zheng, F. (2021). Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers. Micromachines, 12.10.3390/mi12091008 ↗
26. Ryzhkov, M., and Agafonov, V. (2020). Modeling of the MET Sensitive Element Conversion Factor on the Intercathode Distance. Sensors, 20.10.3390/s20185146 ↗
27. Zhou, Q., He, Q., Chen, Y., and Bao, X. (2020). Inlet Effect Caused by Multichannel Structure for Molecular Electronic Transducer Based on a Turbulent-Laminar Flow Model. Sensors, 20.10.3390/s20072154 ↗
28. A Field Self-Adjusting Method for Electrochemical Seismometer Based on Dynamic Feedback Network10.1109/JSEN.2022.3145154 ↗
29. Krylov, A.A., Egorov, I.V., Kovachev, S.A., Ilinskiy, D.A., Ganzha, O.Y., Timashkevich, G.K., Roginskiy, K.A., Kulikov, M.E., Novikov, M.A., and Ivanov, V.N. (2021). Ocean-Bottom Seismographs Based on Broadband MET Sensors: Architecture and Deployment Case Study in the Arctic. Sensors, 21.10.3390/s21123979 ↗
30. Low-Frequency Seismic Node Based on Molecular-Electronic Transfer Sensors for Marine and Transition Zone Exploration10.1175/JTECH-D-16-0254.1 ↗
31. The MEMS-Based Electrochemical Seismic Sensor with Integrated Sensitive Electrodes by Adopting Anodic Bonding Technology10.1109/JSEN.2021.3096496 ↗
32. Frequency characteristics of a spatially-confined electrochemical cell under conditions of convective diffusion10.1023/A:1020293028679 ↗
33. Molecular Electric Transducers as Motion Sensors: A Review10.3390/s130404581 ↗