journal article·2020-01-29Open access

Quick Calculation of Magnetic Flux Density in Electrical Facilities

Carlos Roldán-Blay, Carlos Roldán-Porta

Applied Sciences· Volume 10· Issue 3

Abstract

The World Health Organization (WHO) warns that the presence of magnetic fields due to the circulation of industrial frequency electrical currents may have repercussions on the health of living beings. Hence, it is crucially important that we are able to quantify these fields under the normal operating conditions of the facilities, both in their premises and in their surroundings, in order to take the appropriate corrective measures and assure the safety conditions imposed, in force, by regulations. For this purpose, CRMag® software has been developed. Using the simplified Maxwell equations for low frequencies, CRMag® calculates and represents the magnetic flux density (MFD) that electrical currents produce in the environment. Users can easily model electrical facilities through a friendly and simple data entry. MFDs calculated by CRMag® have been validated in real facilities and laboratory tests. With this software, exposure levels can be studied in any hypothetical scenario, even in inaccessible zones. This allows designers to guarantee that legal limits (occupational, general population, or precautionary levels related to epidemiological studies) are fulfilled. A real case study has been described to show how the reconfiguration of conductors in a distribution transformer substation (DTS) allows significant reductions in MFD in some points outside the facility.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electromagnetic Fields and Biological Effects · Noise Effects and Management · Electrical and Bioimpedance Tomography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Energy Engineering, Universitat Politècnica de València, Camino de Vera, s/n, edificio 8E, escalera F, 46022 Valencia, Spain

References (31)

Show source-provided references
1. Magnetic Fields and Cancer in Children Residing Near Swedish High-voltage Power Lines10.1093/oxfordjournals.aje.a116881 ↗
2. ELECTRICAL WIRING CONFIGURATIONS AND CHILDHOOD CANCER10.1093/oxfordjournals.aje.a112681 ↗
3. A case-control study of childhood leukemia in southern Ontario, Canada, and exposure to magnetic fields in residences10.1002/(SICI)1097-0215(19990719)82:2<161::AID-IJC2>3.0.CO;2-X ↗
4. Childhood leukemia and personal monitoring of residential exposures to electric and magnetic fields in Ontario, Canada10.1023/A:1008919408855 ↗
5. Power-frequency electric and magnetic fields and risk of childhood leukemia in Canada10.1093/oxfordjournals.aje.a009899 ↗
6. Electromagnetic Fields and Cancer in Children Residing Near Norwegian High-Voltage Power Lines10.1093/oxfordjournals.aje.a009094 ↗
7. A pooled analysis of magnetic fields and childhood leukaemia10.1054/bjoc.2000.1376 ↗
8. ICNIRP 2010 International Commission on Non-Ionizing Radiation Protection (2010). Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz). Health Phys., 99, 818–836.10.1097/HP.0b013e3181f06c86 ↗
9. World Health Organization—Electromagnetic Fields and Public Health (2020, January 08). Exposure to Extremely Low Frequency Fields. Available online: https://www.who.int/peh-emf/publications/facts/fs322/en/.
10. (1999). Council Recommendation 1999/519/EC of 12 July 1999 on the limitation of exposure of general public to electromagnetic fields (0 Hz to 300 GHz). Off. J. Eur. Commun. L 199, 30, 59–70.
11. (2020, January 08). Boletín Oficial del Estado. Available online: https://www.boe.es/buscar/pdf/2001/BOE-A-2001-18256-consolidado.pdf.
12. (2008). IEEE Standard for Safety Levels with Respect to Human Exposure to Electromagnetic Fields, 0–3 kHz. IEEE-SASB Coord. Comm.
13. (2020, January 08). International Agency for Research on Cancer Classifies Radiofrequency Electromagnetic Fields as Possibly Carcinogenic to Humans, World Health Organization, Lyon, 2011. Available online: https://www.iarc.fr/wp-content/uploads/2018/07/pr208_E.pdf.
14. The relationship between anatomically correct electric and magnetic field dosimetry and publishedelectric and magnetic field exposure limits10.1093/rpd/ncs064 ↗
15. (2020, January 08). Boletín Oficial del Estado. Available online: https://www.boe.es/boe/dias/2014/06/09/pdfs/BOE-A-2014-6084.pdf.
16. Exploring exposure–response for magnetic fields and childhood leukemia10.1038/jes.2010.38 ↗
17. Magnetic fields exposure and childhood leukemia risk: A meta-analysis based on 11,699 cases and 13,194 controls10.1016/j.leukres.2013.12.008 ↗
18. Exposure to electromagnetic fields (non-ionizing radiation) and its relationship with childhood leukemia: A systematic review10.1016/j.scitotenv.2010.03.039 ↗
19. Residential distance at birth from overhead high-voltage powerlines: Childhood cancer risk in Britain 1962–200810.1038/bjc.2014.15 ↗
20. Childhood leukaemia close to high-voltage power lines—The Geocap study, 2002–200710.1038/bjc.2013.128 ↗
21. Magnetic fields and childhood cancer: An epidemiological investigation of the effects of high-voltage underground cables10.1088/0952-4746/35/3/695 ↗
22. Residential Distance to High-voltage Power Lines and Risk of Neurodegenerative Diseases: A Danish Population-based Case-Control Study10.1093/aje/kws334 ↗
23. Liorni, I., Fiocchi, S., Parazzini, M., Le Brusquet, L., Röösli, M., Struchen, B., and Ravazzani, P. (2017, January 7–9). ELFSTAT Project: Assessment of infant exposure to extremely low frequency magnetic fields (ELFMF, 40–800 Hz) and possible impact on health of new technologies. Proceedings of the 11 ème Congrès National de Radioprotection, Société Française de Radioprotection (SFRP), Lille, France.
24. Childhood leukemia risk in the California Power Line Study: Magnetic fields versus distance from power lines10.1016/j.envres.2019.01.022 ↗
25. Bavastro, D., Canova, A., Freschi, F., Giaccone, L., and Manca, M. (2014). Magnetic field mitigation at power frequency: Design principles and case studies. IEEE Ind. Appl. Soc. Annu. Meet., 1–8.10.1109/IAS.2014.6978470 ↗
26. El centro de transformación integrado y su contribución a la mejora medioambiental
27. Screen selection for the power frequency magnetic field shielding of underground power cables
28. Magnetic induction measurements in high voltage centers of 150/20kV10.1016/j.measurement.2009.03.007 ↗
29. Experimental measurement, analysis and prediction of electric and magnetic fields in open type air substations10.1016/j.epsr.2012.03.014 ↗
30. Simplistic numerical methodology for magnetic field prediction in open air type substations10.1016/j.epsr.2011.08.003 ↗
31. Navarro-Camba, E.A., Segura-García, J., and Gomez-Perretta, C. (2018). Exposure to 50 Hz Magnetic Fields in Homes and Areas Surrounding Urban Transformer Stations in Silla (Spain): Environmental Impact Assessment. Sustainability, 10.10.3390/su10082641 ↗