journal article·2020-11-23Open access

Design of the Cryogenic Bypass Line for the SIS100 Synchrotron

Artur Iluk, Kazimierz Malcher, Wiktor Słomski, Maciej Chorowski, Jarosław Poliński, Thomas Eisel, Branislav Streicher, Peter Spiller

Applied Sciences· Volume 10· Issue 22

Abstract

This paper presents the selected aspects of a superconducting cryogenic bypass line (BPL) design, a part of the international Facility for Antiproton and Ion Research (FAIR) SIS100 cryogenic system, currently under construction in Darmstadt, Germany. Design, manufacturing, and installation of the superconducting cryogenic bypass line is a part of a Polish in-kind contribution to the FAIR project, realized by the Wroclaw University of Science and Technology. The BPL is dedicated to transferring liquid helium and AC electric current between SIS100 arc sections and superconducting quadrupole magnets located in warm straight sections of the synchrotron. A main innovative feature of the cryogenic bypass line is transferring the electric current and liquid helium in one vacuum vessel, while in other similar projects, namely, the Large Hadron Collider at CERN (CH) or the Tevatron at FermiLab (USA), those functions are separated. The coexistence of superconducting busbars and liquid helium process pipes in one limited space, as well as numerous additional functional and technical requirements, was a source of the serious design and production challenges described in the paper, including two designs of the internal suspension system based on steel rods and aramid cables.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Superconducting Materials and Applications · Particle Accelerators and Free-Electron Lasers · Particle accelerators and beam dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Łukasiewicza 7/9, 50-371 Wrocław, Poland

Faculty of Mechanical Power and Engineering, Wrocław University of Science and Technology, Łukasiewicza 7/9, 50-371 Wrocław, Poland

GSI Helmholtz Centre for Heavy Ion Research, 64291 Darmstadt, Germany

Funding

FAIR GmbH Center as part of the in-kind contribution made by the Polish Shareholder in FAIR GmbH (Jagiellonian University), declared by the Polish government in the international FAIR Convention and financed from the state budget.

References (17)

Show source-provided references
1. Polish in-kind contribution to European X-ray Free Electron Laser (XFEL): Status in spring 2013
2. Selected aspects related to the calculations and design of a cryogenic transfer line10.1016/j.acme.2013.11.003 ↗
3. A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator10.1038/s41566-020-0607-z ↗
4. A cryogenic insulating suspension system for the high-resolution airbourne wideband camera (HAWC) and submillimeter and the far-infrared experiment (SAFIRE) adiabatic demagnetization refrigerators (ADRs)
5. The Cryostat of the CUORE Project, a 1-ton Scale Cryogenic Experiment for Neutrinoless Double Beta Decay Research
6. Thermal isolation of large loads at low temperature using Kevlar rope10.1016/0011-2275(93)90124-7 ↗
7. Long term elongation of Kevlar-49 single fiber at low temperature10.1016/j.cryogenics.2012.10.005 ↗
8. Eisel, T., Kauschke, M., Schroeder, C., Streicher, B., Szeligowska, A., Walter, F., and Kollmus, H. (2017, January 15–19). Mass Flow Reduction by a Heater-Capillary Combination for the Cryogenic System of SIS100 at FAIR. Proceedings of the 14th IRR International Conference Cryogenics, Dresden, Germany.
9. Study of Low Loss Experimental Superconducting Nb-Ti Wires to be used in FAIR Magnets10.1109/TASC.2015.2402754 ↗
10. Tomków, Ł., Cholewiński, M., Ciszek, M., and Chorowski, M. (2020). Numerical assessment of thermal behaviour of a superconducting bus-bar with a Nuclotron-type cable. Arch. Electr. Eng., 69.
11. Fydrych, J. (2016). Cryogenic Transfer Lines. Cryostat Design, Springer.10.1007/978-3-319-31150-0_9 ↗
12. Spiller, P.J., Blell, U., Boine-Frankenheim, O., Bozyk, L., Fischer, E., Floch, E., and Klaus, A. (2013, January 12–17). Status of the SIS100 heavy ion synchrotron project at FAIR. Proceedings of the IPAC 2013, THPWO011, Shanghai, China.
13. Heat generation by eddy currents in a shell of superconducting bus-bars for SIS100 particle accelerator at FAIR10.1515/aee-2017-0053 ↗
14. Calculation of inductances and induced currents in cryogenic by-pass line for SIS100 particle accelerator at FAIR
15. Thermal conductivity of Kevlar 49 between 7 and 290 K10.1016/j.cryogenics.2009.08.001 ↗
16. (2020, October 07). NIST Standard Reference Simulation Website, Cryogenic Technologies Group, Available online: https://trc.nist.gov/cryogenics/materials/materialproperties.htm.
17. Eisel, T., Chorowski, M., Iluk, A., Kauschke, M., Kollmus, H., Malcher, K., Polinski, J., and Streicher, B. (July, January 28). Local Cryogenics for the SIS100 at FAIR. IOP Conference Series: Materials Science and Engineering, Advances in Cryogenic Engineering. Proceedings of the Cryogenic Engineering Conference (CEC) 2015, Tucson, AZ, USA.10.1088/1757-899X/101/1/012075 ↗