journal article·2016-10-25Open access

Numerical Analysis on Cross-Shaped Array with Dynamic Transmit Focusing for Enhanced Volumetric Ultrasound Imaging

Suhyun Park, Hyun Kang

Applied Sciences· Volume 6· Issue 11

Abstract

Volumetric ultrasound imaging has been primarily used as a clinical tool to diagnose cardiac dysfunction. However, the modality still suffers from system complexity due to a large number of receive channels for volumetric reconstruction. The aim of the study was to numerically assess a cross-shaped sparse array with a dynamic transmit focusing method to reduce the system complexity and to compensate for the image quality of unfocused volumetric imaging. Analytical simulations with two-way point spread functions demonstrated that the cross-shaped sparse array entailed up to an 84% increase in side-lobes (up to 32 dB), thus leading to significant degradation of the point spread function in the diagonal plane. A dynamic transmit focusing method was able to vividly overcome the image degradation by transmitting more beams with tilting angles. This also yielded a comparable image sensitivity (65 dB) to that of the full array when 31 × 31 tilted waves were used. The proposed cross-shaped sparse array with the dynamic transit focusing method can be used to enhance the frame rate as well as the image quality for unfocused ultrasound imaging.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ultrasound Imaging and Elastography · Ultrasonics and Acoustic Wave Propagation · Photoacoustic and Ultrasonic Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, USA

Department of Biomedical Engineering and Center for Marine-Integrated Biomedical Technology (BK 21 Plus), Pukyong National University, Busan 48513, Korea

Funding

Ministry of Oceans and Fisheries

References (23)

Show source-provided references
1. High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering10.1109/58.68466 ↗
2. Three-dimensional ultrasound scanning10.1098/rsfs.2011.0019 ↗
3. Clinical application of three-dimensional echocardiography: Past, present and future10.1007/BF03086210 ↗
4. Carcinoid tricuspid valve disease: Incremental value of three-dimensional echocardiography10.1093/ejechocard/jer258 ↗
5. Savord, B., and Solomon, R. (2003, January 5–8). Fully sampled matrix transducer for real time 3D ultrasonic imaging. Proceedings of the 2003 IEEE Symposium on Ultrasonics, Honolulu, HI, USA.
6. Hazard, C.R., Fisher, R.A., Mills, D.M., Smith, L.S., Thomenius, K.E., and Wodnicki, R.G. (2003, January 5–8). Annular array beamforming for 2D arrays with reduced system channels. Proceedings of the 2003 IEEE Symposium on Ultrasonics, Honolulu, HI, USA.10.1109/ULTSYM.2003.1293276 ↗
7. The Unifying Role of the Coarray in Aperture Synthesis for Coherent and Incoherent Imaging10.1109/5.54811 ↗
8. Minimally redundant 2-D array designs for 3-D medical ultrasound imaging10.1109/TMI.2008.2010936 ↗
9. Sparse 2D array design for real volumetric imaging10.1109/58.818752 ↗
10. Sparse 2-D arrays for 3-D phased array imaging-design methods10.1109/TUFFC.2002.1026019 ↗
11. Aperture analysis of coarrays for focused ultrasound imaging10.3938/jkps.67.329 ↗
12. Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arrays10.1121/1.390734 ↗
13. Ultrafast imaging in biomedical ultrasound10.1109/TUFFC.2014.2882 ↗
14. High-speed ultrasound volumetric imaging systems—Part II: Parallel processing and image display10.1109/58.68467 ↗
15. Minin, I.V., and Minin, O.V. (2011). Ultrasound Imaging—Medical Applications, INTECH Open Access Publisher.10.5772/689 ↗
16. Jensen, J.A. (1996, January 9–13). Field: A program for simulating ultrasound systems. Proceedings of the 10th Nordicbaltic Conference on Biomedical Imaging, Tampere, Finland.
17. Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers10.1109/58.139123 ↗
18. Christensen, D.A. (1988). Ultrasonic Bioinstrumentation, John Wiley & Sons.
19. Thomenius, K. (1996, January 3–6). Evolution of ultrasound beamformers. Proceedings of the Ultrasonics Symposium, San Antonio, TX, USA.
20. Kotowick, K., Rohling, R., and Lampe, L. (2013, January 7–11). Adaptive compounding of synthetic aperture and compounded plane-wave imaging for fast ultrasonography. Proceedings of the IEEE 10th International Symposium on Biomedical Imaging, San Francisco, CA, USA.10.1109/ISBI.2013.6556592 ↗
21. Nikolov, S.I., Kortbek, J., and Jensen, J.A. (2010, January 11–14). Practical applications of synthetic aperture imaging. Proceedings of the 2010 IEEE International Ultrasonics Symposium, San Diego, CA, USA.10.1109/ULTSYM.2010.5935627 ↗
22. Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography10.1109/TUFFC.2009.1067 ↗
23. Azhari, H. (2010). Basics of Biomedical Ultrasound for Engineers, Wiley-IEEE Press.10.1002/9780470561478 ↗