Calibrated Phase-Shifting Digital Holographic Microscope Using a Sampling Moiré Technique
Source abstract
Abstract
A calibrated phase-shifting digital holographic microscope system capable of improving the quality of reconstructed images is proposed. Phase-shifting errors are introduced in phase-shifted holograms for numerous reasons, such as the non-linearity of piezoelectric transducers (PZTs), wavelength fluctuations in lasers, and environmental disturbances, leading to poor-quality reconstructions. In our system, in addition to the camera used to record object information, an extra camera is used to record interferograms, which are used to analyze phase-shifting errors using a sampling Moiré technique. The quality of the reconstructed object images can be improved by the phase-shifting error compensation algorithm. Both the numerical simulation and experiment demonstrate the effectiveness of the proposed system.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Digital Holography and Microscopy · Image Processing Techniques and Applications · Optical measurement and interference techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research Institute for Measurement and Analytical Instrumentation, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568, Japan
References (18)
Show source-provided references
1. High-resolution quantitative phase-contrast microscopy by digital holography10.1364/OPEX.13.008693 ↗
2. Improved three-dimensional imaging with a digital holography microscope with a source of partial spatial coherence10.1364/AO.38.007085 ↗
3. Zakerin, M., Novak, A., Toda, M., Emery, Y., Natalio, F., Butt, H.J., and Berger, R. (2017). Thermal characterization of dynamic silicon cantilever array sensors by digital holographic microscopy. Sensors, 17.10.3390/s17061191 ↗
4. Three-dimensional microscopy by optical scanning holography10.1117/12.201662 ↗
5. Applications of short-coherence digital holography in microscopy10.1364/AO.44.003977 ↗
6. Optical parameters and space–bandwidth product optimization in digital holographic microscopy10.1364/AO.52.00A410 ↗
7. Three-dimensional microscopy with phase-shifting digital holography10.1364/OL.23.001221 ↗
8. Digital in-line holographic microscopy10.1364/AO.45.000836 ↗
9. Automated Fourier space region-recognition filtering for off-axis digital holographic microscopy10.1364/BOE.7.003111 ↗
10. Off-axis digital hologram reconstruction: Some practical considerations10.1364/AO.50.00H136 ↗
11. Phase-shifting digital holography10.1364/OL.22.001268 ↗
12. Fiber optic phase stepping system for interferometry10.1364/AO.30.000729 ↗
13. Single-exposure phase-shifting digital holography using a random-phase reference wave10.1364/OL.35.002281 ↗
14. A self-calibrating phase-shifting algorithm based on the natural demodulation of two-dimensional fringe patterns10.1364/OE.9.000236 ↗
15. Calibrated phase-shifting digital holography based on dual-camera system10.1364/OL.42.004954 ↗
16. Accuracy of the sampling moiré method and its application to deflection measurements of large-scale structures10.1007/s11340-011-9491-2 ↗
17. Sampling moiré method for accurate small deformation distribution measurement10.1007/s11340-009-9239-4 ↗
18. Theoretical error analysis of the sampling moiré method and phase compensation methodology for single-shot phase analysis10.1364/AO.51.003214 ↗