Numerical Analysis for Performance Evaluation of a Multi-Functional CO2 Heat Pump Water Heating System
Source abstract
Abstract
In recent years, CO2 heat pump water heating systems have been developed, and their performances have been enhanced while their functions have been expanded. In a multi-functional system, used for both hot water supply and bath heating, hot water retrieved from the top of a storage tank is returned to its bottom or side after heat exchange for bath heating, which destroys the stratified temperature distribution in the storage tank and degrades the system performance. In this paper, the performance of a multi-functional CO2 heat pump water heating system has been evaluated by numerical simulation. A system model was created by combining component models for a CO2 heat pump, mixing valves, a storage tank, a heat exchanger, and a bathtub. Partly, perfect mixing by hot water return was assumed in the component model for the storage tank, and its validity was verified through experiments. A performance analysis has been conducted under daily repeated hot water and bath heating demands, and the system performance was evaluated at a periodically steady state. As a result, the system efficiency and the volume of unused hot water in the multi-functional system decreased by 4.9% and 16.3%, respectively, as compared to those in the uni-functional system, when hot water returned to the bottom of the storage tank. When the position for hot water return is heightened, the system efficiency becomes higher than that in the uni-functional system, while the volume of unused hot water decreases furthermore.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Refrigeration and Air Conditioning Technologies · Heat Transfer and Boiling Studies · Adsorption and Cooling Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering, Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai, Osaka 599-8531, Japan
Funding
Japan Society for the Promotion of Science
References (40)
Show source-provided references
1. The Energy Data and Modelling Center, The Institute of Energy Economics, Japan (2013). Handbook of Energy and Economic Statistics in Japan, 2013 Ver., The Energy Conservation Center.
2. Technology and market development of CO2 heat pump water heaters (ECO CUTE) in Japan
3. CO2 heat pump systems10.1016/S0140-7007(01)00033-0 ↗
4. A review of transcritical carbon dioxide heat pump and refrigeration cycles10.1016/j.energy.2013.03.030 ↗
5. CO2-Heat pump water heater: characteristics, system design and experimental results10.1016/S0140-7007(98)00017-6 ↗
6. Modelling the performance of a transcritical CO2 heat pump for high temperature heating10.1016/S0140-7007(01)00021-4 ↗
7. Experimental results of transcritical CO2 heat pump for residential application10.1016/S0360-5442(03)00065-3 ↗
8. Theoretical evaluation of carbon dioxide refrigeration cycle
9. Skaugen, G., Nekså, P., and Pettersen, J. (2002, January 17–20). Simulation of trans-critical CO2 vapour compression systems. Proceedings of the 5th IIR-Gustav Lorentzen Conference on Natural Working Fluids, Guangzhou, China.
10. Performance analysis of a hot water supply system with a CO2 heat pump by numerical simulation (1st report, modeling and analysis of heat pump)10.1299/jsmeb.49.541 ↗
11. Theoretical performance analysis of heat pump water heaters using carbon dioxide as refrigerant10.1002/er.1357 ↗
12. Modeling and simulating the transcritical CO2 heat pump system10.1016/j.energy.2010.09.007 ↗
13. Development and validation of static simulation model for CO2 heat pump10.1016/j.ijheatmasstransfer.2011.01.013 ↗
14. Modeling and simulation of the transcritical CO2 heat pump System10.1016/j.ijrefrig.2013.08.008 ↗
15. Two-stage transcritical carbon dioxide cycle optimization: A theoretical and experimental analysis10.1016/j.ijrefrig.2005.09.004 ↗
16. Heat rejection pressure optimization for a carbon dioxide split system: An experimental study10.1016/j.apenergy.2009.03.006 ↗
17. Experimental investigation on performance of transcritical CO2 heat pump system with ejector under optimum high-side pressure10.1016/j.energy.2012.04.062 ↗
18. Experimental investigation of the optimal rejection pressure for a transcritical CO2 heat pump water heater10.1016/j.applthermaleng.2013.03.045 ↗
19. Subcooling methods for CO2 refrigeration cycles: A review
20. Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications10.1016/j.ijrefrig.2004.03.006 ↗
21. Simulation of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications10.1016/j.ijrefrig.2005.12.006 ↗
22. Performance of a transcritical CO2 heat pump for simultaneous water cooling and heating
23. Modeling and simulation of an activated carbon–CO2 four bed based adsorption cooling system10.1016/j.enconman.2013.06.061 ↗
24. CO2-assisted compression adsorption hybrid for cooling and desalination10.1016/j.enconman.2017.04.009 ↗
25. Transcritical CO2 heat pump systems: Exergy analysis including heat transfer and fluid flow effects10.1016/j.enconman.2004.10.022 ↗
26. Exergoeconomic analysis of carbon dioxide transcritical refrigeration machines10.1016/j.ijrefrig.2013.09.016 ↗
27. Carbon dioxide as refrigerant for tap water heat pumps: A comparison with the traditional solution10.1016/j.ijrefrig.2005.05.019 ↗
28. Residential CO2 heat pump system for combined space heating and hot water heating10.1016/j.ijrefrig.2005.07.006 ↗
29. Theoretical and experimental analysis of a CO2 heat pump for domestic hot water10.1016/j.ijrefrig.2010.12.018 ↗
30. Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles10.1016/j.ijrefrig.2009.12.008 ↗
31. Influence of ambient temperatures on performance of a CO2 heat pump water heating system10.1016/j.energy.2006.06.020 ↗
32. Influence of operation temperatures on performance of a CO2 heat pump water heating system10.1299/jee.3.61 ↗
33. Yokoyama, R. (December, January 30). Exergy analysis of CO2 heat pump water heating systems. Proceedings of the 7th International Symposium on Environmentally Conscious Design and Inverse Manufacturing, Kyoto, Japan.
34. Performance Analysis of a CO2 heat pump water heating system under a daily change in a standardized demand10.1016/j.energy.2009.11.008 ↗
35. Performance analysis of a CO2 heat pump water heating system under a daily change in a simulated demand
36. Numerical analysis on performance enhancement of a CO2 heat pump water heating system by extracting tepid water10.1016/j.energy.2015.05.013 ↗
37. Performance estimation and optimal operation of a CO2 heat pump water heating system10.5541/ijot.449 ↗
38. Performance optimization and analysis of solar combi-system with carbon dioxide heat pump10.1016/j.solener.2013.10.001 ↗
39. (2011). Residential Heat Pump Water Heaters, Japanese Standards Association. Japanese Industrial Standard, No. JIS C 9220: 2011.
40. Yokoyama, R., Okagaki, S., Ito, K., and Takemura, K. (2006, January 12–14). Performance Analysis of a CO2 Heat Pump Water Heating System by Numerical Simulation with a Simplified Model. Proceedings of the 19th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, Aghia Pelagia, Crete, Greece.