Optimized Resolution-Oriented Many-to-One Intensity Standardization Method for Magnetic Resonance Images
Source abstract
Abstract
With the development of big data, Radiomics and deep-learning methods based on magnetic resonance (MR) images, it is necessary to conduct large databases containing MR images from multiple centers. Having huge intensity distribution differences among images reduced or even eliminated, robust computer-aided diagnosis models could be established. Therefore, an optimized intensity standardization model is proposed. The network structure, loss function, and data input strategy were optimized to better avoid the image resolution loss during transformation. The experimental dataset was obtained from five MR scanners located in four hospitals and was divided into nine groups based on the imaging parameters, during which 9152 MR images from 499 participants were collected. Experiments show the superiority of the proposed method to the previously proposed unified model in resolution metrics including the peak signal-to-noise ratio, structural similarity, visual information fidelity, universal quality index, and image fidelity criterion. Another experiment further shows the advantage of the proposed method in increasing the effectiveness of following computer-aided diagnosis models by better preservation of MR image details. Moreover, the advantage over conventional standardization methods are also shown. Thus, MR images from different centers can be standardized using the proposed method, which will facilitate numerous data-driven medical imaging studies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Radiomics and Machine Learning in Medical Imaging · AI in cancer detection · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electronic Engineering, Fudan University, Shanghai 200433, China
Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention (MICCAI) of Shanghai, Shanghai 200433, China
Funding
National Basic Research Program of China (973 Program)
References (28)
Show source-provided references
1. Machine learning for medical imaging10.1148/rg.2017160130 ↗
2. Noninvasive IDH1 mutation estimation based on a quantitative radiomics approach for grade II glioma10.1007/s00330-016-4653-3 ↗
3. Single-subject classification of presymptomatic frontotemporal dementia mutation carriers using multimodal MRI10.1016/j.nicl.2019.101718 ↗
4. Optimized feature selection-based clustering approach for computer-aided detection of lung nodules in different modalities10.1007/s10044-017-0653-4 ↗
5. A network diffusion model of disease progression in dementia10.1016/j.neuron.2011.12.040 ↗
6. Radiomics based targeted radiotherapy planning (Rad-TRaP): A computational framework for prostate cancer treatment planning with MRI10.1186/s13014-016-0718-3 ↗
7. Radiomic analysis reveals prognostic information in T1-weighted baseline magnetic resonance imaging in patients with glioblastoma10.1097/RLI.0000000000000349 ↗
8. Performance analysis of a computer-aided detection system for lung nodules in CT at different slice thicknesses
9. Gao, Y., Shi, Z., Wang, Y., Yu, J., Chen, L., Guo, Y., Zhang, Q., and Mao, Y. (2016, January 15–17). Histological grade and type classification of glioma using Magnetic Resonance Imaging. Proceedings of the 9th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics, Datong, China.10.1109/CISP-BMEI.2016.7853011 ↗
10. New variants of a method of MRI scale standardization10.1109/42.836373 ↗
11. Influence of MRI acquisition protocols and image intensity normalization methods on texture classification10.1016/j.mri.2003.09.001 ↗
12. New methods of MR image intensity standardization via generalized scale10.1118/1.2335487 ↗
13. Histogram-based normalization technique on human brain magnetic resonance images from different acquisitions10.1186/s12938-015-0064-y ↗
14. Robust intensity standardization in brain magnetic resonance images10.1007/s10278-015-9782-8 ↗
15. Jager, F., Deuerling-Zheng, Y., Frericks, B., Wacker, F., and Hornegger, J. (2006, January 22–24). A new method for MRI intensity standardization with application to lesion detection in the brain. Proceedings of the 11th International Fall Workshop Vision, Modeling, and Visualization, Aachen, Germany.
16. Nonrigid registration of joint histograms for intensity standardization in magnetic resonance imaging10.1109/TMI.2008.2004429 ↗
17. Inter-station intensity standardization for whole-body MR data10.1002/mrm.26098 ↗
18. Tissue-based MRI intensity standardization: application to multicentric datasets10.1155/2012/347120 ↗
19. Gao, Y., Pan, J., Guo, Y., Yu, J., Zhang, J., Geng, D., and Wang, Y. (2017, January 18–20). N-D point cloud registration for intensity normalization on magnetic resonance images. Proceedings of the VipIMAGE 2017, Porto, Portugal.10.1007/978-3-319-68195-5_13 ↗
20. Optimised MRI intensity standardisation based on multi-dimensional sub-regional point cloud registration10.1080/21681163.2018.1511477 ↗
21. A universal intensity standardization method based on a many-to-one weak-paired cycle generative adversarial network for magnetic resonance images10.1109/TMI.2019.2894692 ↗
22. Zhu, J.Y., Park, T., Isola, P., and Efros, A.A. (2017, January 22–29). Unpaired image-to-image translation using cycle-consistent adversarial networks. Proceedings of the 2017 IEEE International Conference on Computer Vision, Venice, Italy.10.1109/ICCV.2017.244 ↗
23. Ronneberger, O., Fischer, P., and Brox, T. (2015, January 5–9). U-net: convolutional networks for biomedical image segmentation. Proceedings of the 18th International Conference on Medical Image Computing and Computer Assisted Intervention, Munich, Germany.10.1007/978-3-319-24574-4_28 ↗
24. Ahn, N., Kang, B., and Sohn, K.A. (2018, January 8–14). Fast, accurate, and lightweight super-resolution with cascading residual network. Proceedings of the 2018 European Conference on Computer Vision, Munich, Gemany.10.1007/978-3-030-01249-6_16 ↗
25. Wang, C., Macnaught, G., Papanastasiou, G., MacGillivray, T., and Newby, D. (2018, January 16). Unsupervised learning for cross-domain medical image synthesis uing deformation invariant cycle consistency networks. Proceedings of the 2018 International Workshop on Simulation and Synthesis in Medical Imaging, Granada, Spain.10.1007/978-3-030-00536-8_6 ↗
26. Ji, C., Yu, J., Wang, Y., Chen, L., Shi, Z., and Mao, Y. (2015, January 23–25). Brain tumor segmentation in MR slices using improved GrowCut algorithm. Proceedings of the 7th International Conference on Graphic and Image Processing, Singapore.10.1117/12.2228230 ↗
27. Kendall, A., Gal, Y., and Cipolla, R. (2018, January 18–22). Multi-task learning using uncertainty to weigh losses for scene geometry and semantics. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Salt Lake City, UT, USA.
28. BenTaieb, A., and Hamarneh, G. (2017, January 10–14). Uncertainty driven multi-loss fully convolutional networks for histopathology. Proceedings of the Medical Image Computing and Computer-Assisted Intervention Workshop on Large-scale Annotation of Biomedical data and Expert Label Synthesis (MICCAI LABELS), Quebec City, QC, Canada.10.1007/978-3-319-67534-3_17 ↗