Electromagnetic Testing of Moisture Separation Reheater Tube based on Multivariate Singular Spectral Analysis
Source abstract
Abstract
Moisture separator reheater (MSR) tubing systems are an important part of a pressurized-water power plant to increase the efficiency of the heat transfer rate. The MSR tubes are finned tubes which are made of ferritic stainless steel (SS439) with a high strength and corrosion resistance characteristics. However, corrosion can appear along with the fins after a long period of operation of the MSR tubes that requires nondestructive testing (NDT) of the MSR tubes’ periodically. Electromagnetic testing (ET) is an efficient NDT method for the inspection of far-side corrosion in the MSR tubes. However, the ET sensor signal is affected by signal noise from the fins. Material degradation that make it challenging to inspect and evaluate the corrosion. In this study, we proposed three ET methods, including magnetic flux leakage testing, eddy current testing and partial saturation eddy current testing, and incorporated with a multivariate singular spectral analysis (MSSA) filter to improve the detectability of the corrosion in the MSR tubes. The proposed MSSA filter was compared with the multivariate wavelet transform filter and Gabor transform filter, and the results showed more efficient and stable results of the MSSA filter in the extraction of the corrosion signal.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Structural Health Monitoring Techniques · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Electrical and Electronic Engineering, Phenikaa University, Hanoi 12116, Vietnam
Phenikaa Research and Technology Institute (PRATI), A&A Green Phoenix Group JSC, No.167 Hoang Ngan, Trung Hoa, Cau Giay, Hanoi 11313, Vietnam
Faculty of Marine Engineering, Vietnam Maritime University, Haiphong 180000, Vietnam
IT-based Real-Time NDT Center, Chosun University, Gwangju 61452, Korea
Funding
Vietnam Ministry of Education and Training · Korea Institute of Energy Technology Evaluation and Planning
References (20)
Show source-provided references
1. EPRI (2020, June 05). Moisture Separator Reheater Source Book. Available online: https://www.epri.com/research/products/TR-106345.
2. ASM Handbooks (2018). Electromagnetic Inspection Techniques. Nondestructive Evaluation of Materials, ASM International. Available online: https://dl.asminternational.org/handbooks/book/55/chapter-abstract/648015/Electromagnetic-Inspection-Techniques?redirectedFrom=fulltext.
3. EPRI (2020, June 05). Balance-of Plant Heat Exchanger Condition Assessment and Inspection Guide. Available online: https://www.epri.com/research/products/TR-108009.
4. EPRI Evaluation of the Guided Wave Inspection Technique Using 439 Stainless Steel Finned Tubing. Available online: https://www.epri.com/research/products/GC-109349.
5. Feasibility study of magnetic flux leakage method for condition monitoring of wall thinning on tube10.3233/JAE-2010-1224 ↗
6. Quantitative profile evaluation of natural defects in a steam generator tube from eddy current signals10.3233/JAE-2000-215 ↗
7. Impedance analysis for air-cored cylindrical eddy current coils scanning the surfaces of defect-free conductors10.1080/10589759208953149 ↗
8. Use of type 439L stainless steel tubing in moisture separator/reheaters10.1007/BF02833405 ↗
9. Eddy current testing of type-439 stainless steel tubing using magnetic saturation technique10.1007/s12206-012-0519-z ↗
10. Evaluation of Wall Thinning in Carbon Steel Piping Based on Magnetic Saturation Pulsed Eddy Current Testing Method
11. Electromagnetic testing of moisture separator reheater tubes using a bobbin-type integrated Hall sensor array10.3233/JAE-172274 ↗
12. Nondestructive testing of moisture separator reheater tubing system using Hall sensor array10.1080/10589759.2017.1331231 ↗
13. Signal analysis of a bobbin-type integrated hall sensor array in electromagnetic testing for moisture separator reheater tubes10.3233/JAE-171234 ↗
14. Ramos, H., Postolache, O., and Alegria, F. (2009, January 5–7). Using the skin effect to estimate cracks depths in metallic structures. Proceedings of the Instrumentation and Measurement Technology Conference, Singapore.10.1109/IMTC.2009.5168668 ↗
15. Multivariate de-noising using wavelets and principal component analysis10.1016/j.csda.2004.12.010 ↗
16. Multiscale PCA with application to MSPC monitoring10.1002/aic.690440712 ↗
17. An adaptive-MSSA-based algorithm for detection of trapped victims using UWB radar10.1109/LGRS.2015.2427835 ↗
18. Bobbin-Type Solid-State Hall Sensor Array with High Spatial Resolution for Defects Inspection in Small-Bore Piping Systems10.1109/TMAG.2012.2199472 ↗
19. Estimation of sizes of defects on pipes in nuclear power plants using dipole moment and finite element methods10.1016/j.ndteint.2013.04.008 ↗
20. Eddy current testing and evaluation of far-side corrosion around rivet in jet-engine intake of aging supersonic aircraft10.1007/s10921-014-0242-z ↗