This work addresses the design, analysis, and validation of a transtibial custom prosthesis. The methodology consists of the usage of videometry to analyze angular relationships between joints, moments, and reaction forces in the human gait cycle. The customized geometric model of the proposed prosthesis was defined by considering healthy feet for the initial design. The prosthesis model was developed by considering the Flex-Foot® Variflex® architecture on a design basis. By means of the analytical method, the size and material of the final model were calculated. The behavior of the prosthesis was evaluated analytically by a curved elements analysis and the Castigliano theorem, and numerically by the Finite Element Method (FEM). The outcome shows the differences between the analytical and numerical methods for the final prosthesis design, with an error rate no greater than 6.5%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies · Lower Extremity Biomechanics and Pathologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica Unidad Zacatenco, Sección de Estudios de Posgrado e Investigación, Ciudad de México 07738, Mexico
Instituto Politécnico Nacional, Centro Mexicano para la Producción más Limpia, Acueducto de Guadalupe S/N, La laguna Ticomán, Ciudad de México CP. 07340, Mexico
References (23)
Show source-provided references
1. International Diabetes Federation (2012). Atlas de Diabetes, International Diabetes Federation. [5th ed.]. Available online: https://www.idf.org/e-library/epidemiology-research/diabetes-atlas/20-atlas-5th-edition.html.
2. Diabetes Mellitus en México. El Estado de la Epidemia
3. Gait characteristics of persons with bilateral transtibial amputations10.1682/JRRD.2006.10.0135 ↗
4. Wang, J., and Zielińska, T. (2017). Gait features analysis using artificial neural networks testing the footwear effect. Acta Bioeng. Biomech., 19.
5. Gait characteristics following Achilles tendon elongation: The foot rocker perspective
6. The influence of prosthetic foot alignment on transtibial amputee gait10.3109/03093640309167973 ↗
7. Mechanical and biomechanical analysis of a linear piston design for angular-velocity-based orthotic control10.1682/JRRD.2012.02.0031 ↗
8. Mechanical power and efficiency of level walking with different stride rates10.1242/jeb.000950 ↗
9. Muscular strategy shift in the human running: Dependence of running speed on hip and ankle muscle performance10.1242/jeb.064527 ↗
10. Biomechanical analysis of hip and knee joints during gait in elderly subjects
11. Assessment of transfemoral amputees using C-Leg and Power Knee for ascending and descending inclines and steps10.1682/JRRD.2010.12.0234 ↗
12. A biomechanical model for encoding joint dynamics: Applications to transfemoral prosthesis control10.1152/japplphysiol.01251.2011 ↗
13. Finite element modelling of a residual lower limb in a prosthetic socket: A survey of the development in the first decade10.1016/S1350-4533(98)00027-7 ↗
14. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation
15. Development of a nonlinear finite element modeling of the below-knee prosthetic socket interface10.1016/1350-4533(95)00002-5 ↗
16. Finite element estimates of interface stress in the transtibial prosthesis using gap elements are different from those using automated contact10.1016/S0021-9290(00)00022-1 ↗
17. Finite element modeling of the contact interface between transtibial residual limb and prosthetic socket10.1016/j.medengphy.2004.04.010 ↗
18. Load transfer mechanics between transtibial prosthetic socket and residual limb—Dynamic effects10.1016/j.jbiomech.2003.12.024 ↗
19. Finite element analysis as a tool for parametric prosthetic foot design and evaluation. Technique development in the solid ankle cushioned heel (SACH) foot10.1080/1025584021000048974 ↗
20. Virtual modelling of a prosthetic foot to improve footwear testing. Institution of Mechanical Engineers
21. Özkaya, N., Nordin, M., Goldsheyder, D., and Leger, D. (2012). Fundamentals of Biomechanics: Equilibrium, Motion, and Deformation, Springer-Verlag. [3rd ed.].10.1007/978-1-4614-1150-5 ↗
22. Voegeli, A.V. (2004). Lecciones Básicas de Biomecánica del Aparato Locomotor, Springer-Verlag Iberica. [1st ed.].
23. Boresi, P.A., and Schmidt, R.J. (2020, May 01). Advanced Mechanics of Materials, 6th ed.; John Wiley & Sons, New york, USA 2003. Available online: https://www.brijrbedu.org/Brij%20Data/Advance%20Mechanics%20of%20Solids/Book/Advanced%20Mechanics%20of%20Solids%20By%20Arthur%20P%20Boresi%20&%20Schmidth%206%20Ed.pdf.