journal article·2021-09-21Open access

Optimization of Storage Medium for Hematological Reference Samples in External Quality Assessment

Ngoc Nguyen Vo, Huu Tam Tran, Quan Thuy Truong, Thuy Huong Nguyen

Applied Sciences· Volume 11· Issue 18

Abstract

Hematological reference samples for external quality assessment (EQA) in hematology are essential for many laboratories in Vietnam, however, the prices are high along with short storing time. This study attempted to establish an optimal formula for the manufacture of hematological reference samples for hematological EQA programs. Human red blood cells (RBCs) were mixed with goose RBCs (pseudo-leucocytes) and goat RBCs (pseudo-platelets) as alternatives for white blood cells (WBCs) and platelets (PLTs), respectively, in different formulas of storage media. The optimal formula was obtained using response surface methodology–central composite design (RSM-CCD). Three main factors affecting the concentrations of RBCs were determined by Plackett–Burmann matrix. The optimal concentrations determined by RSM-CCD were 46% serum, 0.44 g/L neomycin sulfate, and 2.5% glycerol. The model predicted that the maximum number of human RBCs was 4.1 × 1012 cells/L, pseudo-leucocytes was 6.4 × 109 cells/L, and pseudo-platelets was 188 × 109 cells/L. The practical concentrations of RBCs, pseudo-leucocytes, and pseudo-platelets were 4.21 × 1012 cells/L, 6.4 × 109 cells/L, and 187 × 109 cells/L, respectively, which showed 98.93% similarity with theoretical data. This result could be a premise for further study to improve manufacturing of hematological reference samples for hematology EQA programs.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Clinical Laboratory Practices and Quality Control · Statistical Methods in Clinical Trials · Reliability and Agreement in Measurement

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biotechnology, Faculty of Chemical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam

Vietnam National University Ho Chi Minh City, Linh Trung Ward, Thu Duc District, Ho Chi Minh City 700000, Vietnam

Center for Standardization and Quality Control in Medical Laboratory of HCMC, 75A Cao Thang Street, District 3, Ho Chi Minh City 700000, Vietnam

References (16)

Show source-provided references
1. External quality assessment of clinical laboratories in the United Kingdom10.1136/jcp.34.9.947 ↗
2. External quality assessment: An effective tool for clinical governance in laboratory medicine10.1515/CCLM.2006.133 ↗
3. The role of the external quality assessment10.11613/BM.2010.019 ↗
4. Kim, Y.R., and Kihara, J.E. (1999). Hematology Reference Control and Method of Preparation. (5,858,790), U.S. Patent.
5. Harrison, G.J., and Lightfoot, T.L. (2006). Diagnostic value of hematology. Clinical Avian Medicine, Spix Publishing Inc.
6. World Health Organization (2016). WHO Manual for Organizing a National External Quality Assessment Programme for Health Laboratories and Other Testing Sites, World Health Organization.
7. Japanese society for laboratory hematology flow cytometric reference method of determining the differential leukocyte count: External quality assurance using fresh blood samples10.1111/ijlh.12607 ↗
8. Turgeon, M.L. (2017). Clinical Hematology: Theory and Procedures, Jones & Bartlett Learning. [6th ed.].
9. The design of optimum multifactorial experiments10.1093/biomet/33.4.305 ↗
10. Response surface methodology: 1966–l988
11. Lewis, S.M. (1998). Quality Assurance in Haematology, World Health Organization.
12. World Health Organization (2004). External Quality Assessment of Transfusion Laboratory Practice—Guidelines on Establishing an EQA Scheme in Blood Group Serology, World Health Organization.
13. Growth of dimorphic human pathogenicfungi on media containing cycloheximide and chloramphenicol10.1007/BF02155508 ↗
14. Optimal combination and concentration of antibiotics in media for isolation of pathogenic fungi and nocardia asteroides10.1128/am.21.2.195-197.1971 ↗
15. ISO Guide 34 (2000). General Requirements for the Competence of Reference Material Proceducers, International Organization for Standard (ISO). [2nd ed.].
16. ISO Guide 35 (2006). Reference Materials—General and Statistical Principles for Certification, International Organization for Standardization (ISO).