journal article·2022-01-18Open access

Mechanical Behaviour and Primary Stability of a Self-Condensing Implant: A Laboratory Critical Simulation of a Severe Maxillary Atrophy on Polyurethane Lamina

Luca Comuzzi, Giovanna Iezzi, Alessandra Lucchese, Natalia Di Pietro, Pierluigi Balice, Camillo D’Arcangelo, Adriano Piattelli, Margherita Tumedei

Applied Sciences· Volume 12· Issue 3

Abstract

Background: Posterior maxillary atrophies could emerge after the loss of teeth, trauma, infections, or lesions that often require regenerative approaches. In these critical conditions, the achievement of implant primary stability represents a clinical challenge in the operative practice. Therefore, a two-stage approach is often preferred with a delay of the rehabilitation time and a consistent increasing of the biological and the operative costs. The aim of this study was to evaluate the mechanical behaviour of a self-condenser implant compared to a standard implant in a critical simulation on different thicknesses and densities of polyurethane lamina. Materials and methods: A total of two implant models were tested: a self-condensing device (test) and a standard implant (control). The study evaluated the insertion torque and the pull-out strength values of the test and control implants inserted in different sizes (1, 2, and 3 mm) and density polyurethane lamina (10, 20, and 30 pcf) for a total of 320 experimental sites. Results: In total, 320 experimental sites were produced in the polyurethane samples. A statistically significant difference of insertion and pull-out torque values between the test and control Implants was found in the different bone densities (p < 0.05). The insertion and pull-out torque values were always higher for the test implants in all experimental conditions. In all bone densities, the insertion torque values were higher than the pull-out torque values. The self-condenser dental implant design evaluated in this in vitro study showed a high level of stability in all experimental conditions. Conclusions: The test implant could represent a useful tool for a one-stage surgical approach in the presence of limited residual native bone as an alternative to a delayed technique.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Independent Researcher, 31015 Conegliano, Italy

Department of Medical, Oral and Biotechnological Sciences University, “G. D’Annunzio” of Chieti-Pescara, 66100 Chieti, Italy

Unit of Orthodontics, Division of Dentistry IRCCS San Raffaele Scientific Institute, 20132 Milan, Italy

Unit of Orthodontics, School of Dentistry, Vita-Salute San Raffaele University, 20132 Milan, Italy

Unit of Dentistry, Research Center for Oral Pathology and Implantology, IRCCS San Raffaele Scientific Institute, 20132 Milan, Italy

Center for Advanced Studies and Technology-CAST (ex CeSI-MeT), University G. D’Annunzio of Chieti-Pescara, 66100 Chieti, Italy

Department of Periodontics, University of Missouri-Kansas City, Kansas City, MO 64030, USA

Biomaterials Engineering, Catholic University of San Antonio de Murcia (UCAM), Av. de los Jerónimos, Guadalupe, 135, 30107 Murcia, Spain

Fondazione Villaserena per la Ricerca, 65121 Città Sant’Angelo, Italy

Casa di Cura Villa Serena del Dott. L. Petruzzi, Via Leonardo Petruzzi 42, 65013 Città Sant’Angelo, Italy

References (68)

Show source-provided references
1. Initial and Long-Term Crestal Bone Responses to Modern Dental Implants10.1111/prd.12176 ↗
2. Healing at Implants Installed in Osteotomies Prepared Either with a Piezoelectric Device or Drills: An Experimental Study in Dogs10.1007/s10006-020-00895-y ↗
3. Healing at implants installed from ~70- to <10-Ncm insertion torques: An experimental study in dogs10.1007/s10006-020-00890-3 ↗
4. Is Titanium Sensitivity Associated with Allergic Reactions in Patients with Dental Implants? A Systematic Review10.1111/j.1708-8208.2010.00330.x ↗
5. Influence of Implant Shape, Surface Morphology, Surgical Technique and Bone Quality on the Primary Stability of Dental Implants10.1016/j.jmbbm.2012.10.010 ↗
6. Gehrke, S.A., Tumedei, M., Aramburú Júnior, J., Treichel, T.L.E., Kolerman, R., Lepore, S., Piattelli, A., and Iezzi, G. (2020). Histological and Histomorphometrical Evaluation of a New Implant Macrogeometry. A Sheep Study. Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17103477 ↗
7. Image-Based Bone Density Classification Using Fractal Dimensions and Histological Analysis of Implant Recipient Site10.5455/aim.2020.28.272-277 ↗
8. Biomechanical Behavior of the Dental Implant Macrodesign10.11607/jomi.4797 ↗
9. A Paradigm Shift for Bone Quality in Dentistry: A Literature Review10.1016/j.jpor.2017.05.006 ↗
10. Correlation between Implant Stability Quotient (ISQ) with Clinical and Histological Aspects of Dental Implants Removed for Mobility10.1177/039463200702001s08 ↗
11. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review10.1155/2014/204838 ↗
12. Primary Implant Stability in the Atrophic Sinus Floor of Human Cadaver Maxillae: Impact of Residual Ridge Height, Bone Density, and Implant Diameter10.1111/clr.12071 ↗
13. Design of Bioactive Bone Substitutes Based on Biomineralization Process10.1016/j.msec.2005.01.002 ↗
14. Influence of Underpreparation on Primary Stability of Implants Inserted in Poor Quality Bone Sites: An in Vitro Study10.1016/j.joms.2015.01.029 ↗
15. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis10.11607/jomi.6285 ↗
16. Removal Torque Values of Titanium Implants Inserted into Bone Defects Filled with Hydroxyapatite: A Histologic and Histomorphometric Analysis in Rabbit10.1177/039463200702001s11 ↗
17. Gehrke, S.A., Mazón, P., Del Fabbro, M., Tumedei, M., Aramburú Júnior, J., Pérez-Díaz, L., and de Aza, P.N. (2019). Histological and Histomorphometric Analyses of Two Bovine Bone Blocks Implanted in Rabbit Calvaria. Symmetry, 11.10.3390/sym11050641 ↗
18. Tumedei, M., Piattelli, A., Degidi, M., Mangano, C., and Iezzi, G. (2020). A Narrative Review of the Histological and Histomorphometrical Evaluation of the Peri-Implant Bone in Loaded and Unloaded Dental Implants. A 30-Year Experience (1988–2018). Int. J. Environ. Res. Public Health, 17.10.3390/ijerph17062088 ↗
19. A 30-Year (1988–2018) Retrospective Microscopical Evaluation of Dental Implants Retrieved for Different Causes: A Narrative Review10.11607/prd.4796 ↗
20. Implant Primary Stability with an Osteocondensation Drilling Protocol in Different Density Polyurethane Blocks10.1080/10255842.2020.1806251 ↗
21. Removal Torque and Histomorphometric Investigation of 4 Different Titanium Surfaces: An Experimental Study in the Rabbit Tibia
22. Correlation Between Resonance Frequency Analysis and Bone Quality Assessments at Dental Implant Recipient Sites10.11607/jomi.4684 ↗
23. Associations of Resonance Frequency Analysis with Dynamic Mechanical Analysis of Dental Implant Systems10.1111/cid.12319 ↗
24. ASTM (1839). 01: Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopedic Devices and Instruments, ASTM.
25. Comuzzi, L., Iezzi, G., Piattelli, A., and Tumedei, M. (2019). An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of NanoShort Dental Implants. Polymers, 11.10.3390/polym11061020 ↗
26. Validation of an Experimental Polyurethane Model for Biomechanical Studies on Implant-Supported Prosthesis—Compression Tests10.1590/S1678-77572011000100010 ↗
27. Validation of an Experimental Polyurethane Model for Biomechanical Studies on Implant Supported Prosthesis—Tension Tests10.1590/S1678-77572011000300012 ↗
28. Bone’s Mechanostat: A 2003 Update10.1002/ar.a.10119 ↗
29. Scarano, A., Noumbissi, S., Gupta, S., Inchingolo, F., Stilla, P., and Lorusso, F. (2019). Scanning Electron Microscopy Analysis and Energy Dispersion X-ray Microanalysis to Evaluate the Effects of Decontamination Chemicals and Heat Sterilization on Implant Surgical Drills: Zirconia vs. Steel. Appl. Sci., 9.10.3390/app9142837 ↗
30. Short Implants versus Bone Augmentation in Combination with Standard-Length Implants in Posterior Atrophic Partially Edentulous Mandibles: Systematic Review and Meta-Analysis with the Bayesian Approach10.1016/j.ijom.2018.05.009 ↗
31. Piezoelectric surgery inserts vs conventional burst: A clinical investigation
32. Short Implants: Analysis of 69 Implants Loaded in Mandible Compared With Longer Implants10.1097/SCS.0000000000004518 ↗
33. Lorusso, F., Conte, R., Inchingolo, F., Festa, F., and Scarano, A. (2021). Survival Rate of Zygomatic Implants for Fixed Oral Maxillary Rehabilitations: A Systematic Review and Meta-Analysis Comparing Outcomes between Zygomatic and Regular Implants. Dent. J., 9.10.3390/dj9040038 ↗
34. Early Implant Failure Associated With Patient Factors, Surgical Manipulations, and Systemic Conditions10.1111/jopr.12978 ↗
35. A Retrospective Analysis of Patients Referred for Implant Placement to a Specialty Clinic: Indications, Surgical Procedures, and Early Failures
36. Histomorphometric Analysis of Bone Regeneration Using a Dual Layer of Membranes (DPTFE Placed over Collagen) in Fresh Extraction Sites: A Canine Model10.1563/AAID-JOI-D-13-00027 ↗
37. The Impact of Different Torques for the Insertion of Immediately Loaded Implants on the Peri-Implant Levels of Angiogenesis- and Bone-Related Markers10.1016/j.ijom.2017.11.001 ↗
38. Implant Stability Measurements in the Long-Term Follow-up of Dentis Implants: A Retrospective Study With Periotest
39. Immediate vs. Early Loading of SLA Implants in the Posterior Mandible: 5-Year Results of Randomized Controlled Clinical Trial10.1111/clr.12072 ↗
40. Evaluation of Dental Implant Insertion Torque Using a Manual Ratchet10.1016/j.mjafi.2013.07.010 ↗
41. An in Vitro Evaluation on Polyurethane Foam Sheets of the Insertion Torque, Removal Torque Values, and Resonance Frequency Analysis (RFA) of a Self-Tapping Threads and Round Apex Implant10.1177/0262489320971796 ↗
42. Primary Stability of Cylindrical and Conical Dental Implants in Relation to Insertion Torque—A Comparative Ex Vivo Evaluation10.1097/ID.0000000000000531 ↗
43. Systematic Review of Survival Rates for Implants Placed in the Grafted Maxillary Sinus10.1016/j.prosdent.2005.04.024 ↗
44. Non-surgical periodontal treatment of peri-implant diseases with the adjunctive use of diode laser: Preliminary clinical study10.1007/s10103-015-1785-7 ↗
45. Pterygoid Implant for Atrophic Posterior Maxilla10.4103/jpbs.JPBS_103_17 ↗
46. A Study of 25 Zygomatic Dental Implants with 11 to 49 Months’ Follow-up after Loading
47. Survival and Complications of Zygomatic Implants: An Updated Systematic Review10.1016/j.joms.2016.06.166 ↗
48. Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects10.12659/MSM.892680 ↗
49. Mavriqi, L., Lorusso, F., Conte, R., Rapone, B., and Scarano, A. (2021). Zygomatic Implant Penetration to the Central Portion of Orbit: A Case Report. BMC Ophthalmol., 21.10.1186/s12886-021-01846-1 ↗
50. Satisfaction Grade Assessment of Patients Treated with Zygomatic Implants with Self-Tapping Apex and Machined Body
51. Scarano, A., de Oliveira, P.S., Traini, T., and Lorusso, F. (2018). Sinus Membrane Elevation with Heterologous Cortical Lamina: A Randomized Study of a New Surgical Technique for Maxillary Sinus Floor Augmentation without Bone Graft. Materials, 11.10.3390/ma11081457 ↗
52. A Novel Technique to Prevent Sinus Membrane Collapse during Maxillary Sinus Floor Augmentation without Bone Graft: Technical Note
53. Simultaneous Sinus Membrane Elevation and Dental Implant Placement without Bone Graft: A 6-Month Follow-up Study10.1902/jop.2010.100343 ↗
54. Overdentures on Implants Placed in Bone Augmented with Fresh Frozen Bone
55. Everstick® and Ribbond® Fiber Reinforced Composites: Scanning Electron Microscope (SEM) Comparative Analysis
56. An Oral Health Aid for Disabled Patients10.1016/S0011-8524(13)70076-X ↗
57. Histomorphometric Evaluation of Two Different Bone Substitutes in Sinus Augmentation Procedures: A Randomized Controlled Trial in Humans10.11607/jomi.4752 ↗
58. Maxillary Sinus Dimensions Decrease as Age and Tooth Loss Increase10.1097/ID.0000000000000551 ↗
59. The Skin Rejuvenation Associated Treatment—Fraxel Laser, Microbotox, and Low G Prime Hyaluronic Acid: Preliminary Results10.1007/s10103-019-02738-z ↗
61. Dentin Permeability after Toothbrushing with Different Toothpastes
62. Biological Effect of Resorbable Plates on Normal Osteoblasts and Osteoblasts Derived From Pfeiffer Syndrome10.1097/SCS.0b013e31820f7d34 ↗
63. Distance between Implants Has a Potential Impact of Crestal Bone Resorption10.1016/j.sdentj.2011.02.002 ↗
64. Prognosis of Third Molar Eruption: A Comparison of Three Predictive Methods
65. Effects of Various Stripping Techniques on Surface Enamel
66. What Is the Best Micro and Macro Dental Implant Topography?10.1016/j.cden.2019.02.010 ↗
67. Periodontal biotype: Characteristic, prevalence and dimensions related to dental malocclusion
68. Lo Giudice, A., Ortensi, L., Farronato, M., Lucchese, A., Lo Castro, E., and Isola, G. (2020). The step further smile virtual planning: Milled versus prototyped mock-ups for the evaluation of the designed smile characteristics. BMC Oral Health, 20.10.1186/s12903-020-01145-z ↗