journal article·2022-02-27Open access

Geometrical Planning of the Medial Opening Wedge High Tibial Osteotomy—An Experimental Approach

Nicolae Florin Cofaru, Valentin Oleksik, Ileana Ioana Cofaru, Carmen Mihaela Simion, Mihai Dan Roman, Ioana Codruta Lebada, Sorin Radu Fleaca

Applied Sciences· Volume 12· Issue 5

Abstract

This article presents an experimental approach to the geometrical planning of the medial opening wedge high tibial osteotomy surgery which, as it is known, is an efficient surgical strategy quite widely used in treating knee osteoarthritis. While most of the published papers focus on analyzing this surgery from a medical point of view, we suggest a postoperative experimental evaluation of the intervention from a biomechanical point of view. The geometrical planning and, more specifically, the determination of the point of intersection between the corrected mechanical axis and the medial-lateral articular line of the knee, is a problem quite often debated in literature. This paper aims to experimentally investigate the behavior of the tibia with an open wedge osteotomy fixed with a locking plate, TomoFix (DE Puy Synthes), taking into account two positions of the mechanical axis of the leg on the width of the tibial plateau, measured from medial to lateral at 50% and 62.5% (Fujisawa point), respectively. The variations of the force relative to the deformation, strains, and displacements resulting from the progressive loading of the tibial plateau are studied. The research results reveal that using the Fujisawa point is better for conducting the correction not only for medical reasons, but also from a mechanical point of view.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Knee injuries and reconstruction techniques · Osteoarthritis Treatment and Mechanisms

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Engineering, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania

Faculty of Medicine, Lucian Blaga University of Sibiu, 550024 Sibiu, Romania

References (49)

Show source-provided references
1. Loading of the knee joint during activities of daily living measured in vivo in five subjects10.1016/j.jbiomech.2010.03.046 ↗
2. A method for concise reporting of joint reaction forces orientation during gait10.1016/j.jbiomech.2016.08.005 ↗
3. Prediction of in vivo joint mechanics of an artificial knee implant using rigid multi-body dynamics with elastic contacts10.1177/0954411914537476 ↗
4. The young osteoarthritic knee: Dilemmas in management10.1186/1741-7015-11-14 ↗
5. Osteoarthritis10.20344/amp.5477 ↗
6. High Tibial Osteotomy for Unloading Osteochondral Defects in the Medial Compartment of the Knee10.1177/0363546508315471 ↗
7. The long-term prognosis for severe damage to weight-bearing cartilage in the knee: A 14-year clinical and radiographic follow-up in 28 young athletes10.3109/17453679608994664 ↗
8. Open Wedge High Tibial Osteotomy and Combined Arthroscopic Surgery in Severe Medial Osteoarthritis and Varus Malalignment: Minimum 5-Year Results10.5792/ksrr.15.075 ↗
9. Ten-Year Results of Medial Open-Wedge High Tibial Osteotomy and Chondral Resurfacing in Severe Medial Osteoarthritis and Varus Malalignment10.1177/0363546518758016 ↗
10. Predictive Factors for and Detection of Lateral Hinge Fractures Following Open Wedge High Tibial Osteotomy: Plain Radiography Versus Computed Tomography10.1016/j.arthro.2018.06.041 ↗
11. How tibiofemoral alignment and contact locations affect predictions of medial and lateral tibiofemoral contact forces10.1016/j.jbiomech.2014.12.049 ↗
12. Influence of Limb Alignment on Mediolateral Loading in Total Knee Replacement: In Vivo measurements in five patients10.2106/JBJS.K.00927 ↗
13. Biomechanics of high tibial osteotomy10.1007/s00167-012-2122-3 ↗
14. Results of high tibial osteotomy: Review of the literature10.1007/s00264-009-0889-8 ↗
15. High Tibial Osteotomy: Review of Techniques and Biomechanics10.1155/2019/8363128 ↗
16. Preoperative planning of medial opening wedge high tibial osteotomy using 3D computer-aided design weight-bearing simulated guidance: Technique and preliminary result10.1177/2309499019831455 ↗
17. (2021, August 15). Tomofix Medial High Tibial Plate for Medial Tibial Osteotomy. Available online: http://www.syntes.com/.
18. Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length10.1097/00003086-199201000-00025 ↗
19. The Effect of High Tibial Osteotomy on Osteoarthritis of the Knee. An arthroscopic study of 54 knee joints10.1016/S0030-5898(20)30753-7 ↗
20. Die zuklappende Tibiakopfosteotomie in der Behandlung der unikompartimentären Arthrose. Closing wedge osteotomy of the tibial head in treatment of single compartment arthrosis10.1007/s00132-003-0600-5 ↗
21. What is the relationship between the “Fujisawa point” and postoperative knee valgus angle? A theoretical, computer-based study10.1016/j.knee.2019.10.018 ↗
22. Clinical efficacy of preoperative 3D planning for reducing surgical errors during open-wedge high tibial osteotomy10.1002/jor.24263 ↗
23. The effect of wedge and tibial slope angles on knee contact pressure and kinematics following medial opening-wedge high tibial osteotomy10.1016/j.clinbiomech.2017.10.021 ↗
24. Computer-Assisted Navigation in High Tibial Osteotomy10.4055/cios.2016.8.4.349 ↗
25. Proximal tibial osteotomy. A critical long-term study of eighty-seven cases10.2106/00004623-199302000-00006 ↗
26. Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study10.2106/00004623-198769030-00005 ↗
27. Juvenile bovine bone is an appropriate surrogate for normal and reduced density human bone in biomechanical testing: A validation study10.1038/s41598-018-28155-w ↗
28. Applicability of bovine tibia as a model in research on various osteosynthesis techniques
29. Cofaru, N.F., Roman, M.D., Cofaru, I.I., Oleksik, V.S., and Fleaca, S.R. (2020). Medial Opening Wedge High Tibial Osteotomy in Knee Osteoarthritis—A Biomechanical Approach. Appl. Sci., 10.10.3390/app10248972 ↗
30. Multi-objective design optimization of high tibial osteotomy for improvement of biomechanical effect by using finite element analysis10.1002/jor.24072 ↗
31. Stress and stability comparison between different systems for high tibial osteotomies10.1186/1471-2474-14-110 ↗
32. Benefits of opposite screw insertion technique in medial open-wedge high tibial osteotomy: A virtual biomechanical study
33. Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone10.1016/j.knee.2016.09.026 ↗
34. Biplanar Open Wedge High Tibial Osteotomy in the Medial Compartment Osteoarthritis of the Knee Joint: Comparison between the Aescula and TomoFix Plate10.4055/cios.2015.7.2.185 ↗
35. Electrochemical Synthesis of Nanostructured Oxide Layers on Threaded Surfaces of Medical Implants10.37358/RC.18.7.6385 ↗
36. Comparison of Different Knee Implants Used on Patients with Osteoarthritis Control Study
37. Cross-cultural adaptation and validation of the Romanian International Knee Documentation Committee—subjective knee form10.7717/peerj.8448 ↗
38. Coronal tibiofemoral subluxation is correlated to correction angle in medial opening wedge high tibial osteotomy10.1007/s00167-018-4948-9 ↗
39. Ioniţescu, M., Vermeşan, D., Andor, B., Dumitrascu, C., Al-Qatawneh, M., Bloanca, V., Dumitrascu, A., and Prejbeanu, R. (2021). Potential New Treatments for Knee OA: A Prospective Review of Registered Trials. Appl. Sci., 11.10.3390/app112211049 ↗
40. Primary stability of four different implants for opening wedge high tibial osteotomy10.1007/s00167-005-0690-1 ↗
41. A Retrospective Comparison of Union Rates After Open Wedge High Tibial Osteotomies with and Without Synthetic Bone Grafts (Hydroxyapatite and β-tricalciumphosphate) at 2 Years10.1016/j.arthro.2018.03.008 ↗
42. Open wedge high tibial osteotomy: Biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate10.1016/j.clinbiomech.2004.06.007 ↗
43. Adding a protective screw improves hinge’s axial and torsional stability in High Tibial Osteotomy10.1016/j.clinbiomech.2020.02.015 ↗
44. Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy10.1007/s00402-018-2918-9 ↗
45. Early full weight bearing is safe in open-wedge high tibial osteotomy RSA analysis of postoperative stability compared to delayed weight bearing10.3109/17453671003619003 ↗
46. Hinge Fractures Are Underestimated on Plain Radiographs After Open Wedge Proximal Tibial Osteotomy: Evaluation by Computed Tomography10.1177/0363546519836949 ↗
47. High Complication Rate After Biplanar Open Wedge High Tibial Osteotomy Stabilized with a New Spacer Plate (Position HTO Plate) Without Bone Substitute10.1016/j.arthro.2011.01.008 ↗
48. Biomechanical properties following open wedge high tibial osteotomy: Plate fixator combined with dynamic locking screws versus standard locking screws10.1016/j.clinbiomech.2018.10.010 ↗
49. Factors affecting stability after medial opening wedge high tibial osteotomy using locking plate: A cadaveric study10.1016/j.knee.2019.07.016 ↗