Analysis of the Refraction Effect in Ultrasound Breast Tomography
Source abstract
Abstract
Ultrasound breast tomography (UBT) is a promising quantitative imaging method. It allows for precise analysis of ultrasound velocity distribution, which is related to tissue density and elasticity, enabling cancer detection. Only a few centers around the world have a prototype of the device for in vivo breast ultrasound tomography imaging. The quality of images reconstructed from measurements of ultrasound pulse transit times is adversely affected by the refraction of beam rays on the breast immersed in water. Refraction can be reduced using waveform tomography, ray-tracing, and ray-linking methods. However, this requires the acquisition of a pre-reconstructed pattern and is limited by extreme computational costs. In this study, the effect of refraction on transit time measurements of ultrasound passing through the female breast was analyzed under immersion conditions in water. It was found that the refraction causes the highest measurement errors in the area of the water/breast interface, and these can be reduced by adjusting the water temperature and changing the breast geometry. The results allow us to improve the quality of breast images reconstructed using an efficient transformation algorithm that assumes rectilinear ultrasound propagation paths between transmitters and receivers. In vivo breast studies were performed on the developed hybrid UBT scanner.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasound Imaging and Elastography · Photoacoustic and Ultrasonic Imaging · Medical Imaging Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Acoustics, Multimedia and Signal Processing, Faculty of Electronics, Photonics and Microsystems, Wroclaw University of Sciences and Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw, Poland
DRAMIŃSKI S.A., Owocowa 17, 10-860 Olsztyn, Poland
Olsztyn Cancer Center “Kopernik”, Kopernika 30, 10-513 Olsztyn, Poland
Funding
Polish National Center for Research and Development (NCBiR)
References (50)
Show source-provided references
1. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries10.3322/caac.21660 ↗
2. (2021, March 21). Breast Cancer. Available online: https://www.who.int/news-room/fact-sheets/detail/breast-cancer.
3. Guidelines on the diagnosis and treatment of breast cancer
4. Estimated risk of radiation-induced breast cancer from mammographic screening for young BRCA mutation carriers10.1093/jnci/djn440 ↗
5. Premedication to reduce discomfort during screening mammography10.1148/radiol.2482071490 ↗
6. The effect of age and density of the breast on the sensitivity of breast cancer diagnostic by mammography and ultrasonography10.1023/A:1010627527026 ↗
7. Negative mammographic and US findings do not help exclude breast cancer10.1148/radiol.2223010939 ↗
8. Mammographic density and the risk and detection of breast cancer10.1056/NEJMoa062790 ↗
9. Outcomes of screening mammography by frequency, breast density, and postmenopausal hormone therapy10.1001/jamainternmed.2013.307 ↗
10. Mammography screening is harmful and should be abandoned10.1177/0141076815602452 ↗
11. Abolishing Mammography Screening Programs? A View from the Swiss Medical Board10.1056/NEJMp1401875 ↗
12. Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer10.1001/jama.299.18.2151 ↗
13. Screening US in patients with mammographically dense breasts: Initial experience with Connecticute Public Acte 09-4110.1148/radiol.12120621 ↗
14. Diagnosis of breast cancer: Contribution of US as an adjunct to mammography10.1148/radiology.213.2.r99nv05413 ↗
15. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts10.1007/s11547-006-0040-5 ↗
16. Reading protocol for dynamic contrast-enhanced MR images of the breast: Sensitivity and specificity analysis10.1148/radiol.2363040735 ↗
17. Ultrasound Tomography: A Breast Imaging Modality Whose Time Has Come
18. Quantitative transmission ultrasound tomography: Imaging and performance characteristics10.1002/mp.12957 ↗
19. 3D Ultrasound Computer Tomography: Hardware Setup, Reconstruction Methods and First Clinical Results10.1016/j.nima.2017.07.019 ↗
20. Multimodal ultrasound computer-assisted tomography: An approach to the recognition of breast lesions10.1016/j.compmedimag.2017.06.009 ↗
21. Hybrid Ultrasound Tomography Scanner—A Novel Instrument Designed to Examine Breast as a Breast Cancer Screening Method
22. Kak, A.C., and Slaney, M. (2001). Principles of Computerized Tomographic Imaging, Society for Industrial and Applied Mathematics.10.1137/1.9780898719277 ↗
23. Opieliński, K.J. (2014, January 7–12). Full Angle Ultrasound Spatial Compound Imaging. Proceedings of the 7th Forum Acusticum, Kraków, Poland.
24. Model of Multipath Propagation of Ultrasonic Pulses in Soft Tissue Using Divergent Beam Tomography Method
25. Glassner, A.S. (1989). An Introduction to Ray Tracing, Academic Press.
26. A ray tracing approach to restoration and resolution enhancement in experimental ultrasound tomography10.1177/016173469001200403 ↗
27. Johan, G., and Bosch, N.D. (2015). Bent Ray Ultrasound Tomography Reconstruction Using Virtual Receivers for Reducing Time Cost. Medical Imaging 2015: Ultrasonic Imaging and Tomography, Proceedings of SPIE Medical Imaging 9419, Orlando, Florida, USA, 21–26 February 2015, International Society for Optics and Photonics.
28. Finite difference computation of traveltimes in very contrasted velocity models: A massively parallel approach and its associated tools10.1111/j.1365-246X.1991.tb03461.x ↗
29. Stephen, J.D., and McAleavey, A. (2010). Robust Ultrasound Travel-Time Tomography Using the Bent Ray Model. Medical Imaging 2010: Ultrasonic Imaging, Tomography, and Therapy, Proceedings of SPIE Medical Imaging 7629, San Diego, CA, USA, 13 February 2010, International Society for Optics and Photonics.
30. Johan, G., Bosh, N.D., and Doyley, M.M. (2014). Toward Real-Time Bent-Ray Breast Ultrasound Tomography Using GPUs. Medical Imaging 2014: Ultrasonic Imaging and Tomography, Proceedings of SPIE Medical Imaging 9040, San Diego, CA, USA, 18–20 February 2014, International Society for Optics and Photonics.
31. Yu, Y., Yi, S., Yue, Z., Yang, X., Jing, J., and Naizhang, F. (2020, January 25–28). A Modified Ray Tracing Method for Ultrasound Computed Tomography in Breast Imaging. Proceedings of the 2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Dubrovnik, Croatia.
32. Tarantola, A. (2005). Inverse Problem Theory and Methods for Model Parameter Estimation, Society for Industrial and Applied Mathematics.10.1137/1.9780898717921 ↗
33. Johan, G., and Bosch, N.D. (2015). High-resolution quantitative whole-breast ultrasound: In vivo application using frequency-domain waveform tomography. Medical Imaging 2015: Ultrasonic Imaging and Tomography, Proceedings of SPIE Medical Imaging 9419, Orlando, Florida, USA, DC, 21–26 Feb 2015, International Society for Optics and Photonics.
34. Taskin, U. (2021). Full-Waveform Inversion for Breast Ultrasound. [Ph.D. Thesis, Delft University of Technology].
35. Refraction-corrected ray-based inversion for three-dimensional ultrasound tomography of the breast10.1088/1361-6420/abc0fc ↗
36. Digital ray tracing in two-dimensional refractive fields10.1121/1.388495 ↗
37. Ray linking for computed tomography by rebinning of projection data10.1121/1.394639 ↗
38. Traycing of rays through a heterogeneous media: An accurate and efficient procedure10.1190/1.1442013 ↗
39. Iterative Ray Tracing between Boreholes for Underground Image Reconstruction10.1109/TGRS.1980.4307496 ↗
40. Duck, F.A. (1990). Physical Properties of Tissue—A Comprehensive Reference Book, Academic Press.10.1016/B978-0-12-222800-1.50010-3 ↗
41. Average velocity of ultrasound in the human female breast10.1121/1.1913526 ↗
42. Main error sources in ultrasound transmission tomography imaging
43. Ultrasound transmission tomography image distortions caused by the refraction effect10.1016/S0041-624X(99)00137-7 ↗
44. Ultrasonic parameters of hen’s egg
45. Reconstruction algorithms: Transform methods10.1109/PROC.1983.12597 ↗
46. Breast skin thickness: Normal range and causes of thickening shown on film-screen mammography
47. (2022, January 10). The Foundation for Research on Information Technologies in Society (IT’IS). Available online: https://itis.swiss/virtual-population/tissue-properties/database/acoustic-properties/.
48. (2019, November 14). Radiopaedia. Available online: https://radiopaedia.org.
49. Local Maximum Intensity Projection (LMIP): A New Rendering Method for Vascular Visualization10.1097/00004728-199811000-00014 ↗
50. D’Orsi, C.J. (2013). 2013 ACR BI-RADS Atlas: Breast Imaging Reporting and Data System, American College of Radiology. [5th ed.].