journal article·2022-04-11Open access

Analysis of Uncertainties in Clinical High-Energy Photon Beam Calibrations Using Absorbed Dose Standards

Fawzia E. M. Elbashir, Wassim Ksouri, Farouk Habbani, Ahmed M. El-Khayatt, Mohamed Hassan Eisa, Ibrahim I. Suliman

Applied Sciences· Volume 12· Issue 8

Abstract

We compared the results of absorbed dose measurements made using the TRS-398, TG-51, and DIN protocols and their associated uncertainties to reduce discrepancies in measurement results made using the three protocols. This experiment was carried out on two Varian Medical linear accelerators with 4, 6, 10, and 20 MV photon energies using FC65-G and CC15 (cylindrical) and NACP-02-type (plane-parallel) ion chambers in water phantoms. The radiation beam quality index (Q) was determined from the measurement of percentage depth dose. It was used to determine the photon beam quality factor required with the ionization chamber calibration factor to convert the ion chamber reading into the absorbed dose to water. For the same beam quality, the TRS-398/TG-51 varied from 0.01% to 1.8%, whereas the ratio for TRS-398/DIN 6800-2 varied from 0.1% to 0.88%. The chamber-to-chamber variation was 0.09% in TRS-398/TG-51, 0.03% in TRS-398/DIN, and 0.02% in TG-51/DIN 6800-2. The expanded uncertainties (k = 1) were 1.24 and 1.25 when using TRS-398 and DIN 6800-2, respectively. Using the aforementioned three protocols, the results showed little chamber-to-chamber variation and uncertainty in absorbed dose measurements. The estimated uncertainties when using cylindrical ion chambers were slightly lower than those measured using plane-parallel chambers. The results are important in facilitating comparisons of absorbed dose measurements when using the three protocols.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Dose and Imaging · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Medical Physics, National Cancer Institute, University of Gezira, Wad Madani P.O. Box 20, Sudan

Department of Medical Physics, Centre de Radiothérapie Hartmann 4, Rue Kleber, CS90004, CEDEX, 92309 Levallois-Perret, France

Department of Physics, Faculty of Science, University of Khartoum, Khartoum P.O. Box 321, Sudan

Department of Physics, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11642, Saudi Arabia

Radiation and Nuclear Safety Institute, Sudan Atomic Energy Commission, Khartoum P.O. Box 3001, Sudan

Funding

Imam Mohammad Ibn Saud Islamic University

References (20)

Show source-provided references
1. AAPM’s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams10.1118/1.598691 ↗
2. (1998). Dosismessverfahren Nach der Sondenmethode für Photonen—Und Elektronenstrahlung Teil 2: Ionisationsdosimetrie DIN 6800-2, Institut für Normung.
3. Code of practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration service10.1088/0031-9155/35/10/301 ↗
4. The Netherlands Commission on Radiation Dosimetry (NCS) (2008). Code of Practice for the Absorbed Dose Determination in High Energy Photon and Electron Beams. NCS Report No. 18, The Netherlands Commission on Radiation Dosimetry.
5. Andreo, P., Burns, D.T., Hohlfeld, K., Huq, M.S., Kanai, T., Laitano, F., Smyth, V., and Vynckier, S. (2000). Absorbed dose determination in external beam radiotherapy: An international code of practice for dosimetry based on standards of absorbed dose to water. IAEA TRS Report. 398, International Atomic Energy Agency.
6. International Atomic Energy Agency (2005). Implementation of the International Code of Practice on Dosimetry in Radiotherapy (TRS 398): Review of Testing Results. IAEA Technical Document (TECDOC-1455), International Atomic Energy Agency.
7. Reference dose determination in 60Co and high-energy radiotherapy photon beams by using Farmer-type cylindrical ionization chambers—An experimental investigation10.1088/2057-1976/ab8b25 ↗
8. A comparison of protocols for external beam radiotherapy beam calibrations10.1016/j.apradiso.2011.11.065 ↗
9. Comparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS-398 and AAPM TG-5110.1120/jacmp.v10i1.2810 ↗
10. ICRU Report 64: Dosimetry of High-Energy Photon Beams Based on Standards of Absorbed Dose to Water
11. Mayles, P., Nahum, A., and Rosenwald, J.C. (2007). Handbook of Radiotherapy Physics: Theory and Practice, CRC Press.10.1201/9781420012026 ↗
12. Institute of Physics and Engineering in Medicine (IPEM) (1999). Physics Aspects of Quality Control in Radiotherapy. IPEM Report No.81, Institute of Physics and Engineering in Medicine (IPEM).
13. Dosimetry and quality specification of high energy photon beams10.3109/02841868609136408 ↗
14. The standard DIN 6800: Procedures for absorbed dose determination in radiology by the ionization method (IAEA-SM-298/31)
15. IAEA (2016). Accuracy Requirements and Uncertainties in Radiotherapy, IAEA.
16. ISO (1995). International Organization for Standardization. Guide to the Expression of Uncertainty in Measurement, ISO.
17. Reference Dosimetry according to the New German Protocol DIN 6800-2 and Comparison with IAEA TRS 398 and AAPM TG 51
18. Determination of absorbed dose to water for high-energy photon and electron beams-comparison of the standards DIN 6800-2 (1997), IAEA TRS 398 (2000) and DIN 6800-2 (2006)
19. Uncertainty in positioning ion chamber at reference depth for various water phantoms10.1016/j.rpor.2018.03.001 ↗
20. Influence of entrance window deformation on reference dosimetry measurement in various beam modalities10.1002/mp.13315 ↗