Respiration Rate Extraction of Moving Subject Using Velocity Change in FMCW Radar
Source abstract
Abstract
We propose a novel approach to determine the respiration rate of a moving subject, in terms of the velocity change, by using a frequency-modulated continuous-wave radar. In conventional methods, the respiration rate is determined by considering the variation in the distance between the targets and radar; however, these methods are vulnerable to the subject’s movements. The proposed approach estimates the respiration rate by considering the velocity, instead of the distance. An experiment was conducted to measure respiration in several subjects performing various movements. The experimental results demonstrate that the proposed method is more robust to the subject’s movements compared to conventional research methods, and can more accurately estimate the respiration rate.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · ECG Monitoring and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electronic Engineering, Soongsil University, Seoul 156743, Korea
References (18)
Show source-provided references
1. Real-time monitoring of respiration rhythm and pulse rate during sleep10.1109/TBME.2006.884641 ↗
2. Shaikh, J.G., and Daimiwal, N.M. (2017, January 6–8). Respiratory parameter measurement and analysis using differential pressure sensor. Proceedings of the 2017 International Conference on Communication and Signal Processing (ICCSP), Chennai, India.10.1109/ICCSP.2017.8286485 ↗
3. Samartkit, P., and Pullteap, S. (2019, January 6–8). Fiber Optic Sensor Applications for Vital Signs Monitoring: A Review. Proceedings of the 2019 7th International Electrical Engineering Congress (iEECON), Hua Hin, Thailand.10.1109/iEECON45304.2019.8938942 ↗
4. Dyspnea10.1016/j.mcna.2005.11.006 ↗
5. Shortrange wideband fmcw radar for millimetric displacement measurements10.1109/TGRS.2013.2291573 ↗
6. Novel signal processing method for vital sign monitoring using fmcw radar10.1016/j.bspc.2016.12.008 ↗
7. Anitori, L., de Jong, A., and Nennie, F. (2009, January 4–8). FMCW radar for life-sign detection. Proceedings of the IEEE Radar Conference, Pasadena, CA, USA.10.1109/RADAR.2009.4976934 ↗
8. A resolution enhancement technique for remote monitoring of the vital signs of multiple subjects using a 24 GHz bandwidth-limited FMCW radar10.1109/ACCESS.2019.2961130 ↗
9. Application of linear-frequency-modulated continuous-wave (LFMCW) radars for tracking of vital signs10.1109/TMTT.2014.2320464 ↗
10. Li, C., Tofighi, M.-R., Schreurs, D., and Horng, J.T.-S. (2016). Principles and Applications of RF/Microwave in Healthcare and Biosensing, Academic.
11. Pace, P.E. (2009). Detecting and Classifying Low Probability of Intercept Radar, Artech House.
12. Respiration Rate Measurement Under 1-D Body Motion Using Single Continuous-Wave Doppler Radar Vital Sign Detection System10.1109/TMTT.2016.2560159 ↗
13. Random Body Movement Cancellation in Doppler Radar Vital Sign Detection10.1109/TMTT.2008.2007139 ↗
14. Munoz-Ferreras, J.-M., Peng, Z., Gomez-Garcia, R., and Li, C. (2016, January 24–27). Random body movement mitigation for FMCW-radar-based vital-sign monitoring. Proceedings of the 2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS), Austin, TX, USA.10.1109/BIOWIRELESS.2016.7445551 ↗
15. Shang, H., Zhang, X., Ma, Y., Li, Z., and Jin, C. (2019, January 11–13). Random Body Movement Cancellation Method for FMCW Radar Vital Sign Detection. Proceedings of the 2019 IEEE International Conference on Signal, Information and Data Processing (ICSIDP), Chongqing, China.10.1109/ICSIDP47821.2019.9173434 ↗
16. Jankiraman, M. (2018). FMCW Radar Design, Artech House.
17. Medical applications of shortwave FM radar: Remote monitoring of cardiac and respiratory motion10.1118/1.3267038 ↗
18. Target Range Selection of FMCW Radar for Accurate Vital Information Extraction10.1109/ACCESS.2020.3043013 ↗