Abstract

Nowadays, voltage sag continues to remain a critical PQ issue in the industry. Since it is not possible to install a voltage analyzer on every node, optimal monitoring locations must be determined. However, during the PQ monitoring campaign of the Lithuanian DSO grid, the execution of this task was inhibited by the lack of knowledge and literature about the fundamentals of voltage sags propagation. Therefore, the first part of this paper investigates the propagation paths of voltage sags by using a voltage sag matrix method on the created test grid, which for the first time is BRELL-based. This paper is the first to not only investigate voltage sags propagation paths (both downward and upward) in detail, but also to investigate them complexly, encompassing all four types of short-circuits, both voltages (phase-to-phase and phase-to-ground), and interconnections with other PQ events (interruption, transient, unbalance). The result has established a generalization of voltage sags propagation mechanisms by inductive reasoning and laid the foundation for the further development of PQ theory. The second part of this paper focuses on the Lithuanian DSO grid and is one of the first to investigate voltage sags/interruptions through the prism of both relationship with reliability indexes (SAIFI and SAIDI) and primary causes. For this purpose, we created our own scientific methodology, applying known probabilistic and statistical methods along with newly proposed approaches, in particular for ACR success evaluation and estimation of functions similarity.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Power Quality and Harmonics · Power Transformer Diagnostics and Insulation · Power System Reliability and Maintenance

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Smart Grids and Renewable Energy Laboratory, Lithuanian Energy Institute, 44403 Kaunas, Lithuania

References (79)

Show source-provided references
1. (2019). IEEE Recommended Practice for Monitoring Electric Power Quality (Standard No. IEEE Std 1159-2019).
2. (2010). Voltage Characteristics of Electricity Supplied by Public Electricity Networks (Standard No. EN 50160:2010).
3. (2016). Electromagnetic Compatibility (EMC)—Part 4-30: Testing and Measurement Techniques—PQ Measurement Methods (IEC 61000-4-30:2015) (Standard No. LST EN 61000-4-30:2015).
4. (2014). IEEE Guide for Voltage Sag Indices (Standard No. IEEE Std 1564-2014).
5. Liubčuk, V., Radziukynas, V., Naujokaitis, D., and Kairaitis, G. (2023). Grid Nodes Selection Strategies for Power Quality Monitoring. Appl. Sci., 13.10.3390/app13106048 ↗
6. Assessment of Voltage Sag/Swell in the Distribution Network Based on Energy Index and Influence Degree Function10.1016/j.epsr.2022.109072 ↗
7. Murray, R.L., and Keith, E.H. (2015). Nuclear Energy, Butterworth-Heinemann. [7th ed.].10.1016/B978-0-12-416654-7.00017-4 ↗
8. Hatamura, Y., Abe, S., Fuchigami, M., and Kasahara, N. (2015). The 2011 Fukushima Nuclear Power Plant Accident, Woodhead Publishing.10.1016/B978-0-08-100118-9.00006-1 ↗
9. European Union (2016). Commission Regulation (EU) 2016/631
10. European Union (2016). Commission Regulation
11. (EU) 2016/631; Network Code on Requirements for Grid Connection of Generators. Off. J. Eur. Union, 59, 1-68. Available online: http://data.europa.eu/eli/reg/2016/631/oj.
12. Green Power Denmark (2022). Guide for Connection of Power-Generating Plants to the Low-Voltage Grid (≤1 kV), Green Power Denmark. Available online: https://greenpowerdenmark.dk/files/media/document/Guide-for-grid-connection-of-demand-installations-to-the%20low-voltage-grid.pdf.
13. Green Power Denmark (2022). Guide for Connection of Power-Generating Plants to the Medium and High-Voltage Grid (>1 kV), Green Power Denmark. Available online: https://greenpowerdenmark.dk/files/media/document/Guide-to-grid-connection-of-demand-facilities-for-the-medium-and-high-voltage-grid_0.pdf.
14. Stanelytė, D., and Radziukynas, V. (2022). Analysis of Voltage and Reactive Power Algorithms in Low Voltage Networks. Energies, 15.10.3390/en15051843 ↗
15. A Review of Voltage Sag Control Measures and Equipment in Power System10.1016/j.egyr.2022.05.158 ↗
16. Large Scale Proactive Power-Quality Monitoring: An Example from Australia10.1109/TPWRD.2016.2562680 ↗
17. Analysis of the Origin of Measured Voltage Sags in Interconnected Networks10.1016/j.epsr.2017.09.008 ↗
18. Locating the Source of Voltage Sags: Full Review, Introduction of Generalized Methods and Numerical Simulations10.1016/j.rser.2017.04.017 ↗
19. Earth Fault Location Based on Evaluation of Voltage Sag at Secondary Side of Medium Voltage/Low Voltage Transformers10.1049/iet-gtd.2014.0460 ↗
20. A Novel Method for Voltage-Sag Source Location Using a Robust Machine Learning Approach10.1016/j.epsr.2016.12.028 ↗
21. On Tracking the Source Location of Voltage Sags and Utility Shunt Capacitor Switching Transients10.1109/TPWRD.2008.923143 ↗
22. Topological Locating of Power Quality Events Source10.5370/JEET.2006.1.2.170 ↗
23. Voltage Sag Source Location: A Review with Introduction of a New Method10.1016/j.ijepes.2012.04.041 ↗
24. Zhang, X., and Xu, Y.H. (2010, January 28–31). Analysis of Voltage Sag Source Location Based on Wavelet-Multiresolution Method. Proceedings of the APPEEC 2010, Chengdu, China.10.1109/APPEEC.2010.5448152 ↗
25. Voltage Sag State Estimation for Power Distribution Systems10.1109/TPWRS.2005.846174 ↗
26. Shao, Z., Peng, J., and Kang, J. (2010, January 24–28). Locating Voltage Sag Source with Impedance Measurement. Proceedings of the POWERCON 2010, Zhejiang, China.
27. A New Approach for Voltage Sag Source Relative Location in Active Distribution Systems with the Presence of Inverter-Based Distributed Generations10.1016/j.epsr.2020.106222 ↗
28. Improved DR and CBM Methods for Finding Relative Location of Voltage Sag Source at the PCC of Distributed Energy Resources10.1016/j.ijepes.2019.105664 ↗
29. Method for Voltage Sag Source Location Based on the Internal Resistance Sign in a Single-Port Network10.1049/iet-gtd.2015.1329 ↗
30. Voltage Sag Source Location Technology Based on Corresponding Sequence Components
31. A Resistance Sign-Based Method for Voltage Sag Source Detection10.1109/TPWRD.2005.852341 ↗
32. Identification of Voltage Sag Source Location Using S and TT Transformed Disturbance Power10.1007/s11771-013-1463-5 ↗
33. Detection of Voltage Sag Sources Based on Instantaneous Voltage and Current Vectors and Orthogonal Clarke’s Transformation10.1049/iet-gtd:20070114 ↗
34. Instantaneous Positive-Sequence Current Applied for Detecting Voltage Sag Sources
35. Liu, Z., Zhang, S., Li, W., Zheng, C., Liu, S., and Wang, L. (2022, January 16–18). Voltage Sag Source Location Based on Sag Event Amplitude Information. Proceedings of the CFEEE 2022, Beihai, China.
36. Bollen, M., Baumann, P., Beyer, Y., Castel, R., Esteves, J., Faias, S., Friedl, W., Larzeni, S., Trhulj, J., and Villa, F. (2013, January 10–13). Guidelines for Good Practice on Voltage Quality Monitoring. Proceedings of the 22nd CIRED, Stockholm, Sweden.10.1049/cp.2013.0685 ↗
37. A New Approach for Optimal Power Quality Monitor Placement in Power System Considering System Topology
38. Optimized Allocation of Power Quality Monitors in Transmission Systems: A Multi-objective Approach10.1016/j.ijepes.2014.06.064 ↗
39. Multi-Objective Optimization for Power Quality Monitoring Allocation Considering Voltage Sags in Distribution Systems10.1016/j.ijepes.2017.10.011 ↗
40. Multi-Objective Approach for Power Quality Monitor Allocation with Symmetry in Short-Duration Voltage Variations10.1109/TPWRD.2018.2890233 ↗
41. Martins, P.E.T., and Oleskovicz, M. (June, January 29). Multi-Objective Optimization Aiming to Minimize the Number of Power Quality Monitors and Multiple Fault Estimations in Unbalanced Power Distribution System. Proceedings of the 20th ICHQP, Naples, Italy.
42. Optimal Monitoring of Voltage Sags Through Simultaneous Analysis of Short-Circuits in Distribution Systems10.1049/iet-gtd.2016.1648 ↗
43. Optimal Power Quality Monitor Placement Using Genetic Algorithm and Mallow’s Cp10.1016/j.ijepes.2013.05.026 ↗
44. Configuration of Power Quality Monitor Considering Voltage Sag Location10.1016/j.epsr.2023.109681 ↗
45. Chiumeo, R., Porrino, A., Garbero, L., Tenti, L., and Nigris, M. (2009, January 8–11). The Italian Power Quality Monitoring System of the MV Network Results of the Measurements of Voltage Dips after 3 Years Campaign. Proceedings of the 20th CIRED, Prague, Czech Republic.10.1049/cp.2009.0952 ↗
46. Mobile Monitoring System to Take Nationwide PQ Measurements on Electricity Transmission System10.1016/j.measurement.2008.09.007 ↗
47. Vinnal, T., Jarkovoi, M., and Kütt, L. (2018, January 12–13). Voltage Dips and Swells in Low Voltage Network of Estonia. Proceedings of the 59th RTUCON, Riga, Latvia.10.1109/RTUCON.2018.8659899 ↗
48. Freitas, A.F., Amaral, F.V., Silva, J.A.L., Saldanha, R.R., and Silva, S.M. (2016, January 16–19). Optimum Allocation of Power Quality Monitors in Electric Power Systems—A Case Study. Proceedings of the 17th ICHQP, Belo Horizonte, Brazil.
49. Methods for Assessing the Robustness of Electrical Power Systems Against Voltage Dips10.1109/TPWRD.2008.2002991 ↗
50. Council of European Energy Regulators (2011). 5th CEER Benchmarking Report on the Quality of Electricity and Gas Supply, CEER.
51. Council of European Energy Regulators (2016). 6th CEER Benchmarking Report on the Quality of Electricity and Gas Supply, CEER.
52. Council of European Energy Regulators (2022). 7th CEER Benchmarking Report on the Quality of Electricity and Gas Supply, CEER.
53. Feng, D., Wang, T., Ying-Ying, L., Zhou, S., and Li, Y. (December, January 29). A New Method for Allocation of Power Quality Monitoring Sites. Proceedings of the 9th IPEMC2020-ECCE Asia, Nanjing, China.10.1109/IPEMC-ECCEAsia48364.2020.9368115 ↗
54. (2022). IEEE Guide for Electric Power Distribution Reliability Indices (Standard No. IEEE Std 1366-2022).
55. Heylen, E., De Boeck, S., Ovaere, M., Ergun, H., and Van Hertem, D. (2018). Dynamic Vulnerability Assessment and Intelligent Control for Sustainable Power Systems, John Wiley & Sons.
56. A Review of Examples and Opportunities to Quantify the Grid Reliability and Resilience Impacts of Energy Efficiency10.1016/j.enpol.2022.113185 ↗
57. Пoлoвкo, A.M. (1964). Ocнoвы Teopии Haдeжнocти, «Hayкa».
58. Navickas, A. (2007). Elektros Energetikos Sistemų Patikimumas, Kaunas University of Technology—Publishing House “Technologija”.
59. A Syncretistic Approach to Grid Reliability and Resilience: Investigations from Minnesota10.1016/j.esr.2021.100726 ↗
60. Toлвинcкaя, E.B. (1978). Элeктpичecкиe Maшины, «Энepгия». [3rd ed.].
61. Блoк, B.M. (1981). , Oбyшeв, Г.K., Пaпepнo, Л.Б., Гyceвa, C.A., Гepxapд, Я.X. Пocoбиe к Kypcoвoмy и Диплoмнoмy Пpoeктиpoвaнию для Элeктpoэнepгeтичecкиx Cпeциaльнocтeй: Учeбнoe Пocoбиe для Cтyдeнтoв Byзoв, «Bыcшaя шкoлa».
62. Svinkūnas, G., and Navickas, A. (2013). Elektros Energetikos Pagrindai, Kaunas University of Technology—Publishing House “Technologija”. [2nd ed.].10.5755/e01.9786090210024 ↗
63. Douglas, C.M., and George, C.R. (2003). Applied Statistics and Probability for Engineers, John Wiley & Sons. [3rd ed.].
64. Johnson, N.L., Kemp, A.W., and Kotz, S. (2005). Univariate Discrete Distributions, John Wiley & Sons. [3rd ed.].10.1002/0471715816 ↗
65. World Nuclear Association (2023, August 12). Nuclear Power in Lithuania. Available online: https://www.world-nuclear.org/information-library/country-profiles/countries-g-n/lithuania.aspx.
66. Statistical Tests, P Values, Confidence Intervals, and Power: A Guide to Misinterpretations10.1007/s10654-016-0149-3 ↗
67. Kalinowski, P. (2010, January 11–16). Identifying Misconceptions about Confidence Intervals. Proceedings of the 8th ICOTS, Ljubljana, Slovenia.
68. Baublys, J., Jankauskas, P., Marckevičius, L.A., and Morkvėnas, A. (2008). Izoliacija ir Viršįtampiai, Kaunas University of Technology—Publishing House “Technologija”.
69. (2013). IEEE Guide for Direct Lightning Stroke Shielding of Substations (Standard No. IEEE Std 998-2012).
70. International Industry Practice on Power Quality Monitoring10.1109/TPWRD.2013.2283143 ↗
71. Paltanavičius, S. (2015). Paukščiai ir Aukštosios Įtampos Linijos. Kada Gyventi Saugu?, “Lututė”.
72. (2023, September 04). Installation of the Bird Protection Measures on the High Voltage Electricity Transmission Grid in Lithuania. Final Report. Available online: http://www.birds-electrogrid.lt/news/159/208/European-Commission-has-approved-the-final-LIFE-Birds-on-Electrogrid-report/d,detalus-en/.
73. Lithuanian Ornithological Society (2023, September 03). Call for Information on Birds Killed by Collision with Power Lines. Available online: https://www.birdlife.lt/kvieciame-teikti-informacija-apie-nuo-susidurimo-s.
74. A Comprehensive Overview on Signal Processing and Artificial Intelligence Techniques Applications in Classification of Power Quality Disturbances10.1016/j.rser.2015.07.068 ↗
75. YouTube (2023, June 24). Autotransformer Equivalent Circuit [Video]. Available online: https://www.youtube.com/watch?v=DRRwWSPEjz0.
76. YouTube (2023, June 24). Equivalent Circuit of Autotransformer [Video]. Available online: https://www.youtube.com/watch?v=-O6_78sp3KM.
77. MathWorks. Help Center (2023, June 25). Three-Phase Autotransformer with Tertiary Winding. Available online: https://www.mathworks.com/help/sps/powersys/ref/threephaseautotransformerwithtertiarywinding.html.
78. MathWorks. Help Center (2023, June 27). Distributed Parameters Line. Available online: https://www.mathworks.com/help/sps/powersys/ref/distributedparametersline.html.
79. Bartkevičius, S., Lazauskas, V., Pukys, P., Stonys, J., and Virbalis, A. (2011). Teorinė Elektrotechnika II, Kaunas University of Technology—Publishing House “Technologija”. [4th ed.].