Search for Optimal Parameters in the Control Structure of a Surgical System for Soft Tissue Operations Based on In Vitro Experiments on Cardiovascular Tissue
Source abstract
Abstract
The surgical robots currently used in cardiac surgery are equipped with a remote center of motion (RCM) mechanism that enables the required spherical workspace. The dynamics model of the surgical robot’s RCM mechanism presented in this work includes a direct current (DC) motor, an optimal proportional–integral–derivative (PID) controller, and a LuGre friction model that takes into account the Stribeck effect and surface deformation. A finite element method (FEM) analysis of transients was carried out using the energy hypothesis of von Mises with an optimal input signal from the mechatronic system with a PID controller obtained using the Runge–Kutta differentiation method in the Dormand–Prince ordinary differential equations variant (ODE45). Five criteria were adopted for the objective function: the safety factor related to the stress function in the time-varying strength problem, the first natural frequency related to stiffness and the resonance phenomenon, the buckling coefficient in the statics problem related to stability, the static factor of safety, and the displacement of the operating tip. The force inputs to the dynamics model were derived from in vitro force measurements on cardiovascular tissue using a force sensor. The normality of the statistical distribution of the experimental data was confirmed using the Kolmogorov–Smirnov statistical test. The problem of multi-criteria optimization was solved using the non-sorter genetic algorithm (NSGA-II), the finite element method, and the von Mises distortion energy hypothesis. Velocity input signals for the transient dynamics model were obtained from a second in vitro experiment on cardiovascular tissue using the minimally robotic invasive surgery (MIRS) technique. An experienced cardiac surgeon conducted the experiment in a modern method using the Robin Heart Vision surgical robot, and a system of four complementary metal–oxide–semiconductor (CMOS) optical sensors and ariel performance analysis system (APAS-XP 2002) software were used to obtain the endoscopic tool trajectory signal. The trajectory signal was accurate to ±2 [mm] in relation to the adopted standard, and it was smoothed using the Savitzky–Golay (SG) polynomial smoothing, whose parameters were optimally selected using the Durbin–Watson (DW) statistical test.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Engineering Technology and Methodologies · Surgical Simulation and Training · Cardiac and Coronary Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Mechatronics, Warsaw University of Technology, ul. św. Boboli 8, 02-525 Warsaw, Poland
References (52)
Show source-provided references
1. Mo, H., Li, X., Ouyang, B., Fang, G., and Jia, Y. (2022). Task Autonomy of a Flexible Endoscopic System for Laser-Assisted Surgery. Cyborg Bionic Syst., 2022.10.34133/2022/9759504 ↗
2. Han, Z., Tian, H., Han, X., Wu, J., Zhang, W., Li, C., Qiu, L., Duan, X., and Tian, W. (2024). A Respiratory Motion Prediction Method Based on LSTM-AE with Attention Mechanism for Spine Surgery. Cyborg Bionic Syst., 6.10.34133/cbsystems.0063 ↗
3. Li, L., Li, X., Ouyang, B., Mo, H., Ren, H., and Yang, S. (2023). Three-Dimensional Collision Avoidance Method for Robot-Assisted Minimally Invasive Surgery. Cyborg Bionic Syst., 4.10.34133/cbsystems.0042 ↗
4. Multi-objective optimization for rapid and robust optimal oilfield development under geological uncertainty10.1007/s10596-015-9507-6 ↗
5. Yang, J., Yu, L., Zhang, N., Wang, L., and Zhao, J. (2017, January 6–9). Dynamic modeling and analysis of laparoscope arm for Minimally Invasive Surgical Robot. Proceedings of the 2017 IEEE International Conference on Mechatronics and Automation (ICMA), Takamatsu, Japan.10.1109/ICMA.2017.8015875 ↗
6. Yang, J., and Lingtao, Y. (2015). Dynamic Characteristics Analysis Based on ADAMS for General Robotic Arm of Minimally Invasive Surgical Robot, IEEE.10.1109/ICMA.2015.7237597 ↗
7. Zhao, B., and Shi, X. (2015, January 25–26). Surgical Robot Control Based on Torque Control Method. Proceedings of the 5th International Conference on Information Engineering for Mechanics and Materials, Hohhot, China.10.2991/icimm-15.2015.309 ↗
8. Konietschke, R., Ortmaier, T., Weiss, H., Engelke, R., and Hirzinger, G. (2003). Optimal Design of a Medical Robot for Minimally Invasive Surgery. Jahrestag. Der Dtsch. Ges. Fuer Comput.-Und Robot. Chir. (CURAC), Available online: https://api.semanticscholar.org/CorpusID:18361233.
9. Contribution to the design of robotized tele-echography system10.1007/s11465-012-0326-3 ↗
10. Laribi, M., Thomas Riviere, T., Marc Arsicault, M., and Saïd Zeghloul, S. (2013, January 6–8). A new teleoperated robotic system for minimally invasive surgery: Modeling and identification. Proceedings of the 2013 International Conference on Control, Decision and Information Technologies (CoDIT), Hammamet, Tunisia.10.1109/CoDIT.2013.6689621 ↗
11. Pose estimation of surgical instrument using sensor data fusion with optical tracker and IMU based on Kalman filter10.1051/matecconf/20153204008 ↗
12. Calibration of tracking systems in a surgical environment10.1109/42.736028 ↗
13. Effective calibration of an endoscope to an optical tracking system for medical augmented reality10.1080/23311916.2017.1359955 ↗
14. Turnip, A., Tampubolon, G., Ramadhan, S., Nugraha, A., Trisanto, A., and Novitam, D. (2021, January 14–16). Development of Medical Robot COVID-19 based 2D mapping LIDAR and IMU Sensors. Proceedings of the 2021 IEEE International Conference on Health, Instrumentation & Measurement, and Natural Sciences (InHeNce), Medan, Indonesia.10.1109/InHeNce52833.2021.9537209 ↗
15. A specific performances comparative study of two spherical robots for tele-echography application10.1177/0954406214530598 ↗
16. Method of dimensional optimization of spherical robots for medical applications using specialized indices10.1080/01691864.2013.861368 ↗
17. Overview of NSGA-II for Optimizing Machining Process Parameters10.1016/j.proeng.2011.08.745 ↗
18. Dimensional optimization of a minimally invasive surgical robot system based on NSGA-II algorithm10.1177/1687814014568541 ↗
19. Multi-objective optimization using genetic algorithms: A tutorial10.1016/j.ress.2005.11.018 ↗
20. Simpson, T., Mistree, F., Korte, J., and Mauery, T. (1998, January 2–4). Comparison of Response Surface and Kriging Models for Multidisciplinary Design Optimization. Proceedings of the 7th AIAA/USAF/NASA/ISSMO Symposium on Multidisciplinary Analysis and Optimization, St. Louis, MO, USA.10.2514/6.1998-4755 ↗
21. Design and analysis of computer experiments
22. Tomasz Strek Finite Element Analysis of Natural Frequencies and Mode Shapes of The da Vinci Medical Robot Arm
23. Zhou, X., Zhang, H., Feng, M., Zhao, J., and Fu, Y. (2018). New remote centre of motion mechanism for robot-assisted minimally invasive surgery. Biomed. Eng. Online, 17.10.1186/s12938-018-0601-6 ↗
24. A family of embedded Runge-Kutta formulae10.1016/0771-050X(80)90013-3 ↗
25. A pair of Runge–Kutta formulas10.1016/0893-9659(89)90079-7 ↗
26. A method of computation for structural dynamics10.1061/JMCEA3.0000098 ↗
27. A survey of Lanchos procedure for very large real ‘symmetric’ eigenvalue problems10.1016/0377-0427(85)90006-8 ↗
28. Performance investigation of PID controller in trajectory control of two-link robotic manipulator in medical robots10.1080/09720502.2021.1893444 ↗
29. Trajectory control of a laparoscopic 3-PUU parallel manipulator based on neural network in SIMSCAPE SIMULINK environment10.1016/j.aej.2022.03.024 ↗
30. Iqbal, S., Suhail, A., Tahi, R., Ghulam, A., and Gulzar, M. (2010). Concept Building through Block Diagram Using Matlab/Simulink, IEEP.
31. Ma, X., Zhou, J., Zhang, Z., and Zhou, Q. (2020). Development of a Robotic Catheter Manipulation System Based on BP Neural Network PID Controller. Biol. Inspired Rehabil. Robot., 2020.10.1155/2020/8870106 ↗
32. Yu, H., Wang, H., Chang, J., Niu, J., Wang, F., Yan, Y., Tian, H., Fang, J., and Lu, H. (2021). A Novel Vascular Intervention Surgical Robot Based on Force Feedback and Flexible Clamping. Appl. Sci., 11.10.3390/app11020611 ↗
33. Robust Interactive PID Controller Design for Medical Robot System
34. Real-time PID control of a novel RCM mechanism designed and manufactured for use in laparoscopic surgery10.1108/IR-09-2019-0179 ↗
35. A New Model for Control of Systems with Friction10.1109/9.376053 ↗
36. Adaptive friction compensation with partially known dynamic friction model10.1002/(SICI)1099-1115(199702)11:1<65::AID-ACS395>3.0.CO;2-3 ↗
37. Adaptive friction compensation with dynamic friction model10.1016/S1474-6670(17)57978-1 ↗
38. Friction Identification Based Upon the LuGre and Maxwell Slip Models10.1109/TCST.2008.921809 ↗
39. Dahl, P. (1968). Technical Report TOR-0158, The Aerospace Corporation.
40. The Robin Heart Vision, telemanipulator for camera holding–preliminary test results
41. Nawrat, Z., Kostka, P., Dybka, W., Rohr, K., Podsędkowski, L., Śliwka, J., Cichoń, R., Zembala, M., and Religa, G. (2010). Pierwsze eksperymenty na zwierzętach robota chirurgicznego Robin Heart. Pomiary Autom. Robot., 539–545.
42. Design and analysis of a novel mechanism with a two-DOF remote centre of motion10.1016/j.mechmachtheory.2020.103990 ↗
43. A family of novel RCM rotational compliant mechanisms based on parasitic motion compensation10.1016/j.mechmachtheory.2020.104168 ↗
44. Zhu, Y.-p., and Fan, Z. (2015). A Novel Remote Center-of Motion Parallel manipulator for Minimally Invasive Celiac Surgery. Int. J. Res. Eng. Sci., 15–19.
45. Using direct linear transformation (DLT) method for aerial photogrammetry applications10.3846/gac.2018.1629 ↗
46. Coplanarity Condition for Photogrammetric Simultaneous and Self-Calibration Block Adjustments
47. Sharon, I., Lendvay, T., and Nisky, I. (2017). Instrument Orientation Based Metrics for Surgical Skill Evaluation in Robot Assisted and Open Needle Driving. arXiv.
48. An uncontrolled manifold analysis of arm joint variability in virtual planar position and orientation tele-manipulation10.1109/TBME.2018.2842458 ↗
49. A Marker-less Technique for Measuring Kinematics in the Operating Room10.1016/j.surg.2016.05.004 ↗
50. Tool-tissue forces in surgery: A systematic review10.1016/j.amsu.2021.102268 ↗
51. Estimation of the friction force during the needle insertion using the disturbance observer and the recursive least square10.1186/s40648-014-0014-7 ↗
52. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature10.3390/s18020561 ↗