Implementation and Evaluation of a Uterine Manipulation System Incorporated with an Existing Tiltable-Tip Uterine Manipulator for Gynecological Laparoscopy
Source abstract
Abstract
In gynecologic surgery, a uterine manipulator is one of the instruments used to perform the laparoscopy. Throughout the past decade, a number of robotic technology applications used for uterine manipulation during surgery have been designed with the aim of increasing the efficiency, improving the precision, and reducing the workload of medical assistants. Although the RCM (Remote Center of Motion) mechanism is one of the key features in a Minimally Invasive Surgical (MIS) robot, the preliminary result in this study, in which the RCM mechanism was applied in a uterine manipulation robot, proved that this may cause unpleasant sensations such as irritation or harm to the nearby area during such manipulation. Therefore, a design of a non-RCM 2-DoF (Degree of Freedom) Robotic Uterine Manipulation System, in cooperation with an existing, reusable and tiltable-tip uterine manipulator, for laparoscopic gynecologic surgery has been proposed and evaluated via a mathematical model along with numerical analysis, a 3D uterus model, and a 1:1 uterus manikin model in order to demonstrate the use of the essential functions. According to the experimental results, the maximum load of 500 g has been handled well by the prototype, with the movement ranges of ±150° in the roll panel and ±90° in the pitch panel (0∼90° for anteversion and 0∼−90° for retroversion, if needed, which can be achieved by rotating the instrument to the other side). Furthermore, to verify this new design prior to its use on patients, and also in consideration of the ethics of human experimentation, through extensive testing on five donated soft-tissue cadavers, the proposed robot received positive feedback from all five surgeons performing the experiments and could offer effective uterine manipulation at the angular velocity of 4 °/s (0.67 RPM) with steady delineation of the vaginal fornices to create necessary motions in the pitch and roll panels of 30∼80° and ±15°, respectively, providing efficient visualization of the uterus. These features make this robot a valuable addition to the surgical instruments available to gynecologic surgeons.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Minimally Invasive Surgical Techniques · Surgical Simulation and Training · Anatomy and Medical Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Computer Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002, Thailand
Department of Obstetrics and Gynecology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
Department of Computer Engineering, Faculty of Engineering, Nakhon Phanom University, Nakhon Phanom 48000, Thailand
Funding
Thai Government Scholarship by NSTDA (National Science and Technology Development Agency)
References (30)
Show source-provided references
1. A New Era of Minimally Invasive Surgery: Progress and Development of Major Technical Innovations in General Surgery Over the Last Decade10.1055/s-0037-1608651 ↗
2. A Novel Technique of Uterine Manipulation in Laparoscopic Pelvic Oncosurgical Procedures: “The Uterine Hitch Technique”
3. A Comparative Survey of Various Uterine Manipulators Used in Operative Laparoscopy10.1007/s10397-006-0215-z ↗
4. (2024, March 05). ALLY Uterine Positioning System-CooperSurgical. Available online: https://www.coopersurgical.com/product/ally-uterine-positioning-system/.
5. (2023, June 05). Side-Kick Basic Holder. Available online: http://www.kronner.com/sidekick.php.
6. (2004). The Development of Uterine Manipulator Holder for Gynecologic Laparoscopic Surgery. Jpn. J. Gynecol. Obstet. Endosc., 20, 68–69.10.5180/jsgoe.20.2_68 ↗
7. Yip, H.M., Li, P., and Liu, Y. (2014, January 28–30). Design and Development of a Robotic Assistant for Uterus Manipulation in Total Laparoscopic Hysterectomy. Proceedings of the 2014 IEEE International Conference on Information and Automation (ICIA), Hailar, China.10.1109/ICInfA.2014.6932681 ↗
8. A Pilot Study of Robotic Uterine and Vaginal Vault Manipulation: The ViKY Uterine Positioner™10.1007/s11701-013-0406-3 ↗
9. Concurrent Use of a Robotic Uterine Manipulator and a Robotic Laparoscope Holder to Achieve Assistant-Less Solo Laparoscopy: The Double ViKY10.1007/s11701-015-0518-z ↗
10. Yip, H.M., Wang, Z., Navarro-Alarcon, D., Li, P., Liu, Y., and Cheung, T.H. (October, January 28). A New Robotic Uterine Positioner for Laparoscopic Hysterectomy with Passive Safety Mechanisms: Design and Experiments. Proceedings of the 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), Hamburg, Germany.10.1109/IROS.2015.7353819 ↗
11. A Collaborative Robotic Uterine Positioning System for Laparoscopic Hysterectomy: Design and Experiments10.1002/rcs.2103 ↗
12. Premachra, H.A.G.C., Herath, H.M.A.N., Thathsarana, K.M., Liyanage, D.L.F.M., Amarasinghe, Y.W.R., Madusanka, D.G.K., and Jayawardane, M.A.M.M. (2022, January 8–10). Design and Development of a Robotic Uterine Manipulator for Gynecological Laparoscopy. Proceedings of the 2022 8th International Conference on Control, Automation and Robotics (ICCAR), Xiamen, China.10.1109/ICCAR55106.2022.9782616 ↗
13. Robot-Enabled Uterus Manipulator for Laparoscopic Hysterectomy with Soft RCM Constraints: Design, Control, and Evaluation10.1109/TMRB.2022.3181497 ↗
14. Design, Control, and Experiments of a Novel Robotic Uterine Manipulator with the Motorized 3-DoF Manipulation Rod10.1109/TBME.2023.3238762 ↗
15. Tsai, W.-N. (2013). A Novel Uterine Manipulator Incorporating Non-Local Controls and Lateral Motion. [Bachelor’s Thesis, Massachusetts Institute of Technology]. Available online: https://dspace.mit.edu/handle/1721.1/83748.
16. Three Degrees of Freedom-Based Master–Slave Uterine Manipulation Robot System for Laparoscopic Hysterectomy10.1115/1.4054608 ↗
17. Baseline Dimensions of the Human Vagina10.1093/humrep/del022 ↗
18. Comparison of Uterine Manipulators Types in Total Laparoscopic Hysterectomy: A Retrospective Study10.12669/pjms.39.4.6728 ↗
19. Comparing two Uterine Manipulators During Total Laparoscopic Hysterectomy: A Randomized Controlled Trial10.1016/j.jmig.2017.02.022 ↗
20. (2024, March 02). TINTARA Uterine Manipulator|KARL STORZ Endoskope|. Available online: https://www.karlstorz.com/th/en/product-detail-page.htm?productID=1000144388&cat=1000194507.
21. Mustaza, S. (2018). Modelling and Control of a Flexible Soft Robotic Uterine Elevator. [Ph.D. Thesis, Department of Electrical and Electronic Engineering, Faculty of Engineering and Physical Sciences, Surrey University].
22. Design and Evaluation of a Bending Actuator for a Robotic Uterine Manipulator, based on a McKibben Pneumatic Artificial Muscle
23. Uterine Manipulator in Total Laparoscopic Hysterectomy: Safety and Usefulness10.1007/s13304-019-00681-w ↗
24. A Family of RCM Mechanisms: Type Synthesis and Kinematics Analysis10.1016/j.ijmecsci.2022.107590 ↗
25. Shi, H., Liang, Z., Zhang, B., and Wang, H. (2023). Design and Performance Verification of a Novel RCM Mechanism for a Minimally Invasive Surgical Robot. Sensors, 23.10.3390/s23042361 ↗
26. The Anatomy of the Pelvic Floor10.1097/00001703-199408000-00003 ↗
27. Does Uterine Manipulator Type Affect Surgical Outcomes of Laparoscopic Hysterectomy?10.4103/GMIT.GMIT_65_20 ↗
28. Human Cadavers to Evaluate Prototypes of Minimally Invasive Surgical Instruments: A Feasibility Study10.3233/THC-171029 ↗
29. (2023, January 01). Matplotlib Python. Available online: https://matplotlib.org/.
30. (2023, March 10). Blender Foundation. Available online: https://www.blender.org/.