Optical Response of Expired EBT3 Film for Absorbed Dose Measurement in X-ray and Electron Beam Range
Source abstract
Abstract
The purpose of this study was to investigate the optical response of an expired External Beam Therapy (EBT3) film, which expired in 2018, using X-rays and electron beam doses. The film’s optical responses were evaluated for its usability in measuring different radiation sources, energy, and absorbed doses ranging up to 5 Gy. Pieces of the expired EBT3 film were irradiated with 90 kVp, 6 MV X-ray photons, and 6 MeV electron beam. The analysis was performed using the Jaz visible spectrometer and EPSON Perfection V370 Photo scanner to obtain the absorbance and the net relative optical density (ROD) of the film samples respectively. The results showed that spectroscopic measurements of the exposed expired EBT3 films under these radiation sources were able to produce primary secondary peaks at λ = 633.52 nm and λ = 582.3 nm respectively. The best wavelength subsets that presented the best MLR regression fitting for all experiments were 541.48 nm, 561.11 nm, and 600.28 nm. While, for the 6 MV photon and the 6 MeV electron beam they were 600.28 nm, 650.79 nm and 654.10 nm. In case of the irradiation with the 6 MV photon and the 6 MeV electron beam, expired EBT3 film showed no significant differences, which made it suitable for dosimetry in various sources of radiation. The individual calibration of radiation dose produces very high measurement accuracy with coefficient of determination, R2 above 0.99 and root mean square of error, RMSE of 0.038 Gy, 0.113 Gy, and 0.115 Gy for films irradiated with 90 kVp X-rays, 6 MV photon beam, and 6 MeV electron beam respectively. Hence, from the results, the expired EBT3 film used in this study showed promising usability of expired EBT3 films beyond their prescribed expiry dates.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Therapy and Dosimetry · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Physics, Universiti Sains Malaysia, Penang 11800, Malaysia
Department of Physics, Faculty of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13318, Saudi Arabia
Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Penang 11800, Malaysia
Department of Allied Medical Sciences-Radiologic Technology, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid 22110, Jordan
References (26)
Show source-provided references
1. Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification10.1016/j.meddos.2006.06.001 ↗
2. Precise radiochromic film dosimetry using a flat-bed document scanner10.1118/1.1929253 ↗
3. Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams10.1016/j.radonc.2009.10.013 ↗
4. Optimization of the Gafchromic TM EBT protocol for IMRT QA10.1016/j.zemedi.2008.09.001 ↗
5. Clinical use of EBT model Gafchromic™ film in radiotherapy10.1118/1.2362876 ↗
6. Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films10.1002/mp.14313 ↗
7. Radiochromic film dosimetry: Considerations on precision and accuracy for EBT2 and EBT3 type films10.1016/j.zemedi.2013.08.002 ↗
8. Analysis of the EBT3 Gafchromic film irradiated with 6 MV photons and 6 MeV electrons using reflective mode scanners10.1016/j.ejmp.2014.04.010 ↗
9. Effects of read-out light sources and ambient light on radiochromic film10.1088/0031-9155/43/8/031 ↗
10. Absorption spectroscopy of EBT model film10.1118/1.2400615 ↗
11. AAPM’s TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams10.1118/1.598691 ↗
12. Polimer Gafchromic EBT3 films in clinical dosimetry10.4028/www.scientific.net/AMR.1084.572 ↗
13. Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams10.1002/mp.13330 ↗
14. Response characterization of EBT-XD radiochromic films in megavoltage photon and electron beams10.1002/mp.13708 ↗
15. Darafsheh, A., Zhao, T., and Khan, R. (2020). Spectroscopic analysis of EBT-XD radiochromic films irradiated with proton and photon therapy beams. Phys. Med. Biol., 65.10.1088/1361-6560/aba28e ↗
16. Spectroscopy and Light Emitting Diodes Based System in Characterizing External Beam Therapy 3 Films for Solar Ultraviolet Measurement10.1007/s13320-019-0565-6 ↗
17. Osman, U.S., and Omar, A.F. (2021). Visible Spectroscopy in EBT3 Solar Ultraviolet Dosimeter, Universiti Sains Malaysia (USM).
18. Radiochromic film dosimetry and its applications in radiotherapy10.1063/1.3576160 ↗
19. Modeling the dose dependence of the vis-absorption spectrum of EBT3 GafChromic™ films10.1002/mp.12246 ↗
20. Use of radiochromic film as a high-spatial resolution dosimeter by Raman spectroscopy10.1118/1.4955119 ↗
21. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan10.1118/1.4754797 ↗
22. Characterization of Gafchromic EBT3 films for ultraviolet radiation dosimetry10.1080/10420150.2013.848446 ↗
23. Measuring solar UV radiation with EBT radiochromic film10.1088/0031-9155/55/20/N01 ↗
24. Auto-development issue in quality assurance of biological X-ray irradiator using Gafchromic EBT3 film10.1016/j.rinp.2017.01.010 ↗
25. Chiu-Tsao, S., Massillon-Jl, G., Domingo-Muñoz, I., and Chan, M. (2012). SU-E-T-96: Energy Dependence of the New GafChromic-EBT3 Film’s Dose Response-Curve. Med. Phys., 39.10.1118/1.4735153 ↗
26. Casanova Borca, V., Pasquino, M., Russo, G., Grosso, P., Cante, D., Sciacero, P., Girelli, G., la Porta, M.R., and Tofani, S. (2013). Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification. J. Appl. Clin. Med. Phys., 14.10.1120/jacmp.v14i2.4111 ↗