Finite Element Analysis of Maxillary Teeth Movement with Time during En Masse Retraction Using Orthodontic Mini-Screw
Source abstract
Abstract
Introduction: The aim of this study was to determine the placement of an orthodontic mini-screw (OMS) and the length of an anterior retraction hook (ARH) with en masse retraction. Continuous maxillary tooth movement pattern was simulated by finite element analysis (FEA). Materials and methods: Extraction of the first premolar was hypothesized with a finite element model. The placement of OMS was analyzed for the following two groups: (1) a high OMS (HOMS) group with OMS placed horizontally at the mesial side of the second premolar and apically 10 mm above the arch wire, and (2) a low OMS (LOMS) group with OMS placed horizontally between the second premolar and the first molar and apically 8 mm above the arch wire. According to the height of ARH, each group was divided into three subgroups. Results: When the extraction space of the first premolar was closed, anterior teeth were intruded in the HOMS group but extruded in the LOMS group. In all cases, the first molar was intruded. According to the intrusion of the first molar and extrusion of anterior teeth, the occlusal plane rotated clockwise (CW) in the LOMS group. However, in the HOMS1 group, the occlusal plane rotated counterclockwise (CCW) due to more intrusion of anterior teeth than that of the first molar. Conclusion: By analyzing six cases of different OMS and ARH, changes of incisor and molar in en masse retraction with the extraction of the first premolar could be predicted. In addition, OMS placement and ARH length can be determined based on results of incisal showing. This study can also help esthetic orthodontic results.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · dental development and anomalies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Clinical Dental Science, The Catholic University of Korea, Seoul 06591, Republic of Korea
Division of Orthodontics, Department of Dentistry, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 07345, Republic of Korea
References (26)
Show source-provided references
1. Optimal loading condition for controlled movement of anterior teeth in sliding mechanics10.2319/111608-587R.1 ↗
2. Distalization pattern of whole maxillary dentition according to force application points10.4041/kjod.2015.45.1.20 ↗
3. Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis10.1016/j.ajodo.2008.06.036 ↗
4. Experimental determination of optimal force system reguired for control of anterior tooth movement in sliding mechanics10.1016/j.ajodo.2007.01.034 ↗
5. A finite element simulation of initial movement, orthodontic movement, and the centre of resistance of the maxillary teeth connected with an archwire10.1093/ejo/cjr123 ↗
6. Biomechenical analysis for total distalization of the mandibular dentition: A finite element study10.1016/j.ajodo.2018.05.014 ↗
7. Finite Element Analysis of the Effect of Force Directions on Tooth Movement in Extraction Space Closure with Miniscrew Sliding Mechanics10.1016/j.ajodo.2012.05.014 ↗
8. Biomechanical features of tooth movement from a lingual appliance in comparison with a labial appliance during space closure in sliding mechanics10.1016/j.ajodo.2021.03.024 ↗
9. Hamanaka, R., Cantarella, D., Lombardo, L., Karanxha, L., Fabbro, M.D., Siciliani, G., and Yoshida, N. (2021). Dual-section versus conventional archwire for en-masse retraction of anterior teeth with direct skeletal anchorage: A finite element analysis. BMC Oral Health, 21.10.1186/s12903-021-01443-0 ↗
10. Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position10.4041/kjod.2016.46.4.242 ↗
11. Factors Controlling Anterior Torque with C-Implants Depend on En-Masse Retraction without Posterior Appliances: Biocreative Therapy Type II Technique10.1016/j.ajodo.2010.09.023 ↗
12. Finite-element investigation of the center of resistance of the maxillary dentition10.4041/kjod.2009.39.2.83 ↗
13. The straight-wire appliance. Explained and compared
14. Three biologic variables modifying faciolingual tooth angulation by straight-wire appliances10.1016/0889-5406(89)90350-8 ↗
15. A three-dimentional finite element analysis on the location of center of resistance during intrusion of upper anterior teeth
16. The thickness of the human periodontal membrane
17. Histologic study of the influence of function on the human periodontal membrane
18. Restorative margins and periodontal health: A new look at an old perspective10.1016/0022-3913(87)90363-5 ↗
19. Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces10.1016/0889-5406(87)90232-0 ↗
20. Numerical simulation ofthe biomechanical behaviour of multi-root teeth10.1093/ejo/cji020 ↗
21. Determination of the elasticity parameters of the human periodontal ligament and the location of the center of resistance of single-rooted teeth a study of autopsy specimens and their conversion into finite element models10.1007/s00056-002-0067-8 ↗
22. Factors influencing the axes of anterior teeth during SWA en mase sliding retraction with orthodontic mini-implant anchorage: A finite element study
23. Biological reaction of alveolar bone to orthodontic tooth movement
24. Gummy smile correction using mini implant
25. Displacement pattern of the maxillary arch depending on miniscrew position in sliding mechanics10.1016/j.ajodo.2010.05.020 ↗
26. Treatment Effects of Mini-Implants for En-Masse Retraction of Anterior Teeth in Bialveolar Dental Protrusion Patients: A Randomized Controlled Trial10.1016/j.ajodo.2007.03.025 ↗