journal article·2023-09-02Open access

Optimization of Data Acquisition System Based on Electrical Impedance Tomography in Dredging Engineering

Ning Liu, Shihong Yue, Yibo Wang

Applied Sciences· Volume 13· Issue 17

Abstract

Electrical impedance tomography (EIT) is an advanced visualization detection technique with non-invasive, radiationless, and fast-response characteristics. As an important means in dredging engineering, EIT-based measurement can realize the estimate and computation of key flow parameters such as the flow velocity and solid phase fraction of solid-liquid two-phase flow in a pipe. Despite progress, both the data acquisition rate and the signal-to-noise ratio (SNR) of the existing EIT system are too low to meet many practical requirements. In this study, efforts are made concerning the EIT acquisition system by optimizing the sensor array, data acquisition system, and data communication module. Experimental results show that (1) the optimized system has an SNR of 73 dB, which is about 40% higher than the original system, and (2) the optimization of data transmission methods can achieve a maximum allowable transmission rate of 316.4 Mbps, sufficient to support data transmission over 1000 frames per second. Consequently, the key problems of the existing EIT acquisition system are substantially overcome.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrical and Bioimpedance Tomography · Flow Measurement and Analysis · Non-Destructive Testing Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China

Funding

National Natural Science Foundation of China

References (26)

Show source-provided references
1. J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): Phantom experiments for static resistivity images10.1109/TMI.2002.800604 ↗
2. Image Reconstruction Based on Convolutional Neural Network for Electrical Resistance Tomography10.1109/JSEN.2018.2876411 ↗
3. The Sheffield data collection system10.1088/0143-0815/8/4A/012 ↗
4. A real-time electrical impedance tomography system for clinical use-design and preliminary results10.1109/10.341825 ↗
5. Mk3.5: A modular, multi-frequency successor to the Mk3a EIS/EIT system10.1088/0967-3334/22/1/307 ↗
6. Assessment and Calibration of a Low-Frequency System for Electrical Impedance Tomography (EIT), Optimized for Use in Imaging Brain Function in Ambulant Human Subjects10.1111/j.1749-6632.1999.tb09500.x ↗
7. Design and implementation of a high frequency electrical impedance tomography system10.1088/0967-3334/25/1/041 ↗
8. Electrical impedance imaging system using FPGAs for flexibility and interoperability10.1186/1475-925X-13-126 ↗
9. Cui, Z.Q., Wang, H.X., Tang, L., Zhang, L., Chen, X., and Yan, Y. (2008, January 12–15). A specific data acquisition scheme for electrical tomography. Proceedings of the 2008 IEEE Instrumentation and Measurement Technology Conference, Victoria, BC, Canada.10.1109/IMTC.2008.4547132 ↗
10. A biological electrical impedance imaging hardware system based on multi period undersampling technology
11. Unsupervised Evaluation and Optimization for Electrical Impedance Tomography10.1109/TIM.2021.3123218 ↗
12. Research on swept frequency electrical impedance tomography system
13. Wu, J.C., Yue, S.H., and Ma, H.T. (2021, January 17–20). An experimental device for calibration of concentration and velocity of two-phase flow based on electrical impedance measurement system. Proceedings of the 2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Glasgow, UK.10.1109/I2MTC50364.2021.9460020 ↗
14. Xin, C.H. (2022). Electrical Impedance Tomography Design and Calculation Technology for Fraction Estimation in Dredging Engineering. [Master’s Thesis, Tianjin University].
15. Wang, P. (2012). Electrical Resistance Tomography (ERT) Technology and Its Application in Two-Phase Flow Detection. [Doctoral Dissertation, Xidian University].
16. Numerical Analysis of the Electromagnetic Fields in a Microwave Plasma Source Excited by Azimuthally Symmetric Surface Waves10.1143/JJAP.41.2199 ↗
17. Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography10.1007/BF02523842 ↗
18. Electrical resistance tomography of metal walled vessels and pipes10.1049/el:19940540 ↗
19. An analysis of electrical properties of metal electrodes10.1007/BF02474626 ↗
20. Xu, Y.B. (2004). Research on Communication Method of Electrical Resistance Tomography System Based on USB Technology. [Master Dissertation, Tianjin University].
21. A high-performance EIT system10.1109/JSEN.2005.843904 ↗
22. Development of a new data acquisition system for electrical capacitance tomography
23. A small aperture high pressure capacitance tomography system based on PCI bus
24. Improvements on real-time performance of electrical capacitance tomography
25. Research on embedded electrical impedance measurement system
26. A Broadband High-Frequency Electrical Impedance Tomography System for Breast Imaging10.1109/TBME.2007.903516 ↗