Influence of Apparatus Scale on Geogrid Monotonic and Cyclic/Post-Cyclic Pullout Behavior in Cohesive Soils
Source abstract
Abstract
Geosynthetics have increasingly been applied to geotechnical engineering works due to their numerous advantages, including cost-effectiveness and their significant role in sustainable development. When geosynthetics are used as reinforcement in earth structures, such as embankments, retaining walls and bridge abutments, soil–geosynthetic interface shear behavior is a critical parameter involved in the design. This paper presents a series of monotonic and cyclic/post-cyclic pullout tests carried out to examine the apparatus scale effect on the pullout response of a geogrid embedded in two different soils. To assess the small-scale equipment feasibility, comparisons were made between pullout test parameters derived from small- and large-scale equipment. The test results indicate that, under a low confining stress of 25 kPa, using a smaller-sized apparatus results in lower values of geogrid pullout resistance and maximum mobilized shear stress, but higher values of confined tensile stiffness at low strains. On the other hand, as the confining stress increases (i.e., 50 kPa and 100 kPa), the difference between the results becomes less significant and similar trends are observed regardless of the equipment type. Adopting small-scale equipment enables obtaining soil–reinforcement interaction parameters using test procedures that are less time-consuming than those associated with large-scale pullout tests. However, proper scale effect correction factors may be considered for more consistent estimates of the interface strength parameters under low normal stress values.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Soil Stabilization · Geotechnical Engineering and Soil Mechanics · Landfill Environmental Impact Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
São Carlos School of Engineering, University of São Paulo (USP), São Carlos 13563-120, Brazil
Faculty of Engineering and Sciences of Guaratinguetá, São Paulo State University (UNESP), Guaratinguetá 12516-410, Brazil
CONSTRUCT, Faculty of Engineering, University of Porto, R. Dr. Roberto Frias, 4200-465 Porto, Portugal
Funding
Fundação para a Ciência e Tecnologia (FCT) · FCT/MCTES (PIDDAC)
References (49)
Show source-provided references
1. Effectiveness of a Reinforcing Geogrid in a Railway Subbase under Dynamic Loads10.1016/0266-1144(94)90041-8 ↗
2. Berg, R., Christopher, B., and Samtani, N. (2009). Design and Construction of Mechanically Stabilized Earth Walls and Reinforced Soil Slopes—Volume I, Fhwa.
3. Local Stiffness Characteristic of Geogrid-Stabilized Aggregate in Relation to Accumulated Permanent Deformation Behavior10.1016/j.geotexmem.2019.01.005 ↗
4. Healing the World: A Geosynthetics Solution
5. Sand-Geotextile Interface Characterisation through Monotonic and Cyclic Direct Shear Tests10.1680/gein.12.00037 ↗
6. Soil-Geosynthetic Interaction: Modelling and Analysis10.1016/j.geotexmem.2009.03.003 ↗
7. Effect of Progressive Failure on Measured Shear Strength of Geomembrane/GCL Interface10.1061/(ASCE)1090-0241(2008)134:4(459) ↗
8. The Shear Behavior Obtained from the Direct Shear and Pullout Tests for Different Poor Graded Soil-Geosynthetic Systems
9. Scale and Other Factors Affecting the Results of Pull out Tests of Grids Buried in Sand10.1680/geot.1989.39.3.511 ↗
10. Pull-Out Resistance of Geogrid Reinforcements10.1016/0266-1144(93)90003-7 ↗
11. Influence of the Confinement, Soil Density and Displacement Rate on Soil-Geogrid Interaction10.1016/S0266-1144(97)83184-6 ↗
12. The Pull-Out Resistance of Geogrids in Reinforced Soil10.1016/0266-1144(96)00027-1 ↗
13. Influence of Rigid and Flexible Face on Geogrid Pullout Tests10.1016/S0266-1144(01)00011-5 ↗
14. Factors Affecting the Pullout Behaviour of Extruded Geogrids Embedded in a Compacted Granular Soil10.1016/j.geotexmem.2006.03.001 ↗
15. Pullout Resistance of Individual Longitudinal and Transverse Geogrid Ribs10.1061/(ASCE)1090-0241(2007)133:1(37) ↗
16. Geogrid Pullout Behaviour According to the Experimental Evaluation of the Active Length10.1680/jgein.15.00042 ↗
17. Pullout Response of Strengthened Geosynthetic Interacting with Fine Sand10.1016/j.geotexmem.2019.02.006 ↗
18. Ferreira, F.B., Vieira, C.S., and Lopes, M.D.L. (2020). Pullout Behavior of Different Geosynthetics—Influence of Soil Density and Moisture Content. Front. Built Environ., 6.10.3389/fbuil.2020.00012 ↗
19. Pullout Behaviour of Geosynthetics in a Recycled Construction and Demolition Material—Effects of Cyclic Loading10.1016/j.trgeo.2020.100346 ↗
20. Soil-Geosynthetic Interface Strength and Stiffness Relationships from Pullout Tests10.1680/gein.6.0156 ↗
21. Bearing Force Mobilisation in Pull-out Tests on Geogrids10.1016/j.geotexmem.2004.03.007 ↗
22. Investigating Geogrid-Reinforced Ballast: Experimental Pull-out Tests and Discrete Element Modelling10.1016/j.sandf.2013.12.001 ↗
23. Experimental and Numerical Analysis of Large Scale Pull out Tests Conducted on Clays Reinforced with Geogrids Encapsulated with Coarse Material10.1016/j.geotexmem.2014.07.008 ↗
24. Pullout Resistance of Bearing Reinforcement Embedded in Marginal Lateritic Soil at Molding Water Contents10.1016/j.geotexmem.2015.07.016 ↗
25. Experimental Investigation on the Pullout Behaviour of Geosynthetics Embedded in a Granite Residual Soil10.1080/19648189.2015.1090927 ↗
26. Vieira, C.S., Pereira, P., Ferreira, F., and de Lurdes Lopes, M. (2020). Pullout Behaviour of Geogrids Embedded in a Recycled Construction and Demolition Material. Effects of Specimen Size and Displacement Rate. Sustainability, 12.10.3390/su12093825 ↗
27. Monotonic and Cyclic Pull-out Resistance of Geogrids10.1680/geot.1997.47.2.331 ↗
28. Influence of Cyclic Tensile Loading on Pullout Resistance of Geogrids Embedded in a Compacted Granular Soil10.1016/j.geotexmem.2009.09.019 ↗
29. The Influence of a Cyclic Loading History on Soil-Geogrid Interaction under Pullout Condition10.1016/j.geotexmem.2019.01.012 ↗
30. Study on Pullout Behavior of Uniaxial HDPE Geogrids Under Monotonic and Cyclic Loads
31. Deformative Behaviour of Different Geogrids Embedded in a Granular Soil under Monotonic and Cyclic Pullout Loads10.1016/j.geotexmem.2011.11.001 ↗
32. Cyclic and Post-Cyclic Shear Behaviour of a Granite Residual Soil—Geogrid Interface10.1016/j.proeng.2016.06.048 ↗
33. Geosynthetics Under Cyclic Pullout and Post-Cyclic Monotonic Loading10.1007/s40891-016-0053-7 ↗
34. Post-Cycling Interface Strength Test of Geogrids10.1007/s40999-020-00518-3 ↗
35. HDPE Geogrid-Residual Soil Interaction under Monotonic and Cyclic Pullout Loading10.1680/jgein.19.00057 ↗
36. Reinforcement Bond Capacity10.1680/geot.1990.40.3.513 ↗
37. Small-Scale Pullout Test of a Geogrid-Reinforced Unsaturated Soil with Suction Monitoring10.1520/GTJ20150182 ↗
38. Marques, G.S., and Lins da Silva, J. (2020). Interaction Between a Lateritic Soil and a Non-Woven Geotextile in Different Moisture Conditions. Front. Built Environ., 6.10.3389/fbuil.2020.00116 ↗
39. Kakuda, F.M. (2006). Geogrid Pullout Tests Using Reduced Scale Equipment. [Master’s Thesis, University of São Paulo]. (In Portuguese).
40. (2021). Standard Test Method for Measuring Geosynthetic Pullout Resistance in Soil (Standard No. ASTM D6706-01).
41. (2020). Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Standard No. ASTM D4767-11).
42. (2020). Standard Test Method for Consolidated Drained Triaxial Compression Test for Soils (Standard No. ASTM D7181-20).
43. Strength Enhancement of Clay by Encapsulating Geogrids in Thin Layers of Sand10.1016/j.geotexmem.2009.06.001 ↗
44. Pullout Tests Conducted on Clay Reinforced with Geogrid Encapsulated in Thin Layers of Sand10.1016/j.geotexmem.2011.04.004 ↗
45. Teixeira, H.S.C. (1999). Construction and Calibration of a Large Pullout Test Device. [Master’s Thesis, University of São Paulo]. (In Portuguese).
46. (2014). Standard Test Method for Measuring Geosynthetic-Soil Resilient Interface Shear Stiffness (Standard No. ASTM D7499/D7499M-09).
47. Pullout Behavior of Polymeric Strip in Compacted Dry Granular Soil under Cyclic Tensile Load Conditions10.1016/j.jrmge.2018.04.007 ↗
48. Visualization of Load Transfer Behaviour between Geogrid and Sand Using PFC2D10.1016/j.geotexmem.2014.01.001 ↗
49. Design Method for Geogrid-Reinforced Unpaved Roads. I. Development of Design Method10.1061/(ASCE)1090-0241(2004)130:8(775) ↗