The residual magnetism of the iron core of power transformers can cause an excitation inrush current, posing a threat to the safe and stable operation of the power grid. This paper proposes a transformer remanence measurement method based on a demagnetization hysteresis loop to address the problems of large errors, complex operation, and poor universality in existing remanence measurement methods. This method is designed for off-grid transformers to avoid potential interference to the power grid caused by current pulses during the measurement process. This method constructs an RLC oscillation circuit that utilizes capacitor energy storage and iron core magnetic field energy conversion, combined with the dynamic characteristics of hysteresis loops, to achieve accurate measurement of residual magnetism and synchronous demagnetization. The effectiveness of this method has been verified through residual magnetism measurement experiments on ring transformers and large converter transformers, and it can be applied in specific engineering practice operations. Theoretical analysis shows that the charging range of energy storage capacitors is affected by the hysteresis characteristics of the iron core and the saturation magnetic flux, and the residual magnetization value can be directly calculated based on the difference in the intersection point of the longitudinal axis of the demagnetization hysteresis loop. Simulation and experimental results show that the measurement error of the proposed method is less than 5%—significantly better than traditional methods. This method does not require complex control strategies, has high precision and efficiency, and can provide reliable technical support for residual magnetism detection and suppression of off-grid power transformers.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnetic Properties and Applications · Non-Destructive Testing Techniques · Optical measurement and interference techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

National Key Laboratory of Transmission and Transformation Equipment Technology, Chongqing University, Chongqing 400044, China

State Grid Chongqing Electric Power Company Qijiang Power Supply Branch, Chongqing 400044, China

China Southern Power Grid Corporation Limited Ultra High Voltage Transmission Company Electric Power Research Institute, Guangzhou 510000, China

Funding

China Southern Power Grid Program

References (39)

Show source-provided references
1. Research Overview of Measurement Methods for Residual Magnetism in Power Transformer Cores
2. Research on the Residual Magnetic Flux Density Measurement of Single-Phase Transformer Based on Magnetomotive Force
3. Determining the residual magnetic flux value of a single-phase transformer using a minor hysteresis loop10.1109/TPWRD.2020.3019407 ↗
4. A novel residual magnetism detection method of power transformer cores based on magnetization time10.1109/JSEN.2023.3340565 ↗
5. Laboratory setup for determining residual magnetic flux value using low voltage DC source10.1007/s00202-020-00988-7 ↗
6. Accurate transformer inrush current analysis by controlling closing instant and residual flux10.1016/j.epsr.2023.109638 ↗
7. Pan, Z., Zheng, T., Guo, Y., and Pan, L. (2023, January 22–25). Cause analysis and anti-vibration performance study of gas relay in the process of no-load closing of converter transformer. Proceedings of the Annual Meeting of CSEE Study Committee on HVDC Power Electronics (HVDC), Nanjing, China.10.1049/icp.2023.3022 ↗
8. Improved flux-controlled VFCV strategy for eliminating and measuring the residual flux of three-phase transformers10.1109/TPWRD.2019.2937900 ↗
9. Nilsson, L., Eriksson, M., and Johansson, J. (2023, January 18–20). Sensitivity analysis of transformer frequency responses. Proceedings of the 14th International Electrical Insulation Conference (INSUCON), Birmingham, UK.
10. An inrush current suppression strategy for UHV converter transformer based on simulation of magnetic bias10.1109/TPWRD.2022.3173431 ↗
11. Energization transient suppression of 750 kV AC filters using a preinsertion resistor circuit breaker with a controlled switching device10.1109/TPWRD.2021.3128617 ↗
12. Analysis and suppression of operational overvoltage and inrush current for high-speed trains by automatic phase-switching technique10.1049/hve2.12417 ↗
13. Flux error function based controlled switching method for minimizing inrush current in 3-phase transformer10.1109/TPWRD.2020.2995519 ↗
14. Inrush current suppression technology for floating nuclear power plants based on connecting preT in series10.1016/j.ijepes.2021.107508 ↗
15. Reduction of three-phase transformer inrush currents using controlled switching10.1109/TIA.2019.2955627 ↗
16. A simplified phase-controlled switching strategy for inrush current reduction10.1109/TPWRD.2020.2984234 ↗
17. Detecting CVT measurement errors using a voltage online monitoring system and maximum approximate coefficient growth rate10.1109/JSEN.2024.3459054 ↗
18. A novel method for CVT transient transform characteristics improvement integrated with digital filter suppressing voltage oscillation10.1109/TIM.2024.3381253 ↗
19. Research on data-driven self-diagnosis for measurement errors in capacitor voltage transformers
20. Study on short-circuit current interruption characteristics of double-break fast vacuum circuit breaker within the minimum arcing time10.1016/j.ijepes.2022.108865 ↗
21. A new method to measure the residual flux by magnetic sensors and a finite-element model
22. Song, J., Zheng, T., Guo, Y., and Pan, L. (2023, January 21–23). Suppression strategy of the inrush current in the transformer phase selection closing considering the residual flux. Proceedings of the 6th Asia Conference on Energy and Electrical Engineering (ACEEE), Chengdu, China.10.1109/ACEEE58657.2023.10239668 ↗
23. Residual flux measurement of the single-phase transformer based on transient current method10.1109/TASC.2020.2975192 ↗
24. Research on residual flux density measurement for single-phase transformer core based on energy changes10.1109/TIM.2021.3117087 ↗
25. Residual flux density measurement method for transformer core considering relative differential permeability10.1109/TMAG.2020.3003658 ↗
26. A review of research progress on residual magnetism detection methods for power transformer cores10.1109/JSEN.2024.3349604 ↗
27. New method to measure deep-saturated magnetizing inductances for dual reversible models of single-phase two-winding transformers10.1109/TEC.2020.3023596 ↗
28. Lv, J., Zhang, Z., Lu, H., Li, B., and Ding, L. (2024). Measurement method of deeply saturated excitation characteristics of converter transformer under AC-DC hybrid excitation. Electronics, 13.10.3390/electronics13234691 ↗
29. Modified Preisach Model of Hysteresis in Multi Air Gap Ferrite Core Medium Frequency Transformer10.1109/TPWRD.2021.3054059 ↗
30. Impacts of Ferroresonance and Inrush Current Forces on Transformer Windings10.1049/iet-epa.2018.5193 ↗
31. Demagnetization Method for Reducing Inrush Current of Single Phase 1 kVA Transformer
32. Elimination of Transformer Inrush Currents by Controlled Switching—Part I: Theoretical Considerations10.1109/61.915495 ↗
33. Residual Magnetic Flux of On-Load Transformer for Controlled Switching10.1002/tee.23172 ↗
34. Applications of a Theory of Ferromagnetic Hysteresis10.1109/20.43893 ↗
35. Elimination of Residual Flux in Transformers by the Application of an Alternating Polarity DC Voltage Source10.1109/TPWRD.2014.2377199 ↗
36. Remanent Flux Negative Effects on Transformer Diagnostic Test Results and a Novel Approach for Its Elimination10.1109/TPWRD.2018.2827179 ↗
37. Study of Resistive Type SFCL for Limiting Inrush Current of LCC-HVDC Converter Transformer10.1109/TASC.2021.3101771 ↗
38. Study on the Residual Flux Density Measurement Method for Power Transformer Cores Based on Magnetising Induction10.1049/elp2.12148 ↗
39. A Saturated Amorphous Alloy Core-Based Inrush Current Limiter to Eliminate Inrush Currents and Restrain Harmonics during Transformer Energization10.1109/TIA.2021.3114665 ↗