journal article·2025-05-21Open access

Efficacy of a Low-Cost Weight-Bearing Sensitivity Incentivator After Lower Limb Surgery: A Pilot Randomised Controlled Trial

Alessandro Manelli, Isella Carola, Fabrizio Mancini, Schiavone Nicola, Rathlef Daniel, Marina Protasoni, Andrea Brambilla, Piero Antonio Zecca

Applied Sciences· Volume 15· Issue 10

Abstract

Background: Accurate partial weight-bearing (PWB) is essential for postoperative recovery after lower limb surgery, yet patients often fail to maintain load within clinically meaningful thresholds. Methods: In this pilot randomised controlled trial with 1:1 concealed allocation, 34 inpatients aged 18–85 who underwent femoral fracture fixation, hip arthroplasty, or knee arthroplasty were enrolled and followed for 14 days. Participants were randomly assigned to either standard physiotherapy or the same protocol with a low-cost tactile insole (“incentiviser”) that provides mechanical feedback when the prescribed 20% body weight (BW) load is exceeded. The primary outcome was absolute deviation from target load, with a minimal clinically important difference (MCID) of ±2 kg. Results: In total, 88% of the intervention group achieved the MCID at discharge versus 24% of controls. The between-group difference in final load error was 10.8 kg (95% CI: −15.2 to −6.4), with a large effect size (Cohen’s d = 1.71). No significant differences were found in pain (NRS) or walking distance (6MWT) between groups. Conclusions: The tactile incentiviser significantly improved PWB accuracy within 14 days, meeting MCID thresholds in most cases. Its low cost and simplicity make it promising for routine or home-based use. Limitations include the small sample, diagnosis heterogeneity, and absence of a sham control. Larger multicentre trials are needed to confirm generalisability and long-term clinical impact.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Pain Management and Treatment · Cardiac, Anesthesia and Surgical Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Neuroscience and Neurorehabilitation, ASL1 SSR Liguria, 18038 San Remo, Italy

Private Practice, 13900 Biella, Italy

Private Practice, 06240 Nice, France

Novaggio Rehabilitation Clinic, 6986 Novaggio, Ticino, Switzerland

Department of Medicine and Technological Innovation, University of Insubria, 21100 Varese, Italy

Funding

University of Insubria

References (35)

Show source-provided references
1. Orthopedic inpatients’ ability to accurately reproduce partial weight bearing orders10.3928/01477447-20131219-10 ↗
2. Audio-Biofeedback Versus the Scale Method for Improving Partial Weight-Bearing Adherence in Healthy Older Adults: A Randomised Trial10.1007/s00068-024-02609-5 ↗
3. Accuracy of Partial Weight Bearing After Autologous Chondrocyte Implantation10.1016/j.apmr.2008.02.019 ↗
4. Is the AO Guideline for Postoperative Treatment of Tibial Plateau Fractures Still Decisive? A Survey Among Orthopaedic Surgeons and Trauma Surgeons in the Netherlands10.1007/s00402-017-2718-7 ↗
5. Bjelland, Ø., Gulliksen, W., Kwiatkowski, A.D., Skavø, M., Isern, H., Shayestehpour, M., Steinert, M., Bye, R.T., and Hellevik, A.I. (2023, January 10–13). Implementation and Evaluation of a Vibrotactile Assisted Monitoring and Correction System for Partial Weight-Bearing in Lower Extremities. Proceedings of the 2023 IEEE World Haptics Conference (WHC), Delft, The Netherlands.10.1109/WHC56415.2023.10224413 ↗
6. Partial Weight Bearing in Hip Fracture Rehabilitation10.4155/fsoa-2017-0068 ↗
7. A Wearable Biofeedback Device for Monitoring Tibial Load During Partial Weight-Bearing Walking10.1109/TNSRE.2023.3305205 ↗
8. Current advances in training orthopaedic patients to comply with partial weight-bearing instructions
9. Tamburella, F., Lorusso, M., Tagliamonte, N.L., Bentivoglio, F., Bigioni, A., Pisotta, I., Lancini, M., Pasinetti, S., Ghidelli, M., and Masciullo, M. (2021). Load Auditory Feedback Boosts Crutch Usage in Subjects With Central Nervous System Lesions: A Pilot Study. Front. Neurol., 12.10.3389/fneur.2021.700472 ↗
10. van Lieshout, R., Pisters, M.F., Vanwanseele, B., de Bie, R.A., Wouters, E.J., and Stukstette, M.J. (2016). Biofeedback in Partial Weight Bearing: Usability of Two Different Devices from a Patient’s and Physical Therapist’s Perspective. PLoS ONE, 11.10.1371/journal.pone.0165199 ↗
11. Real-time pressure mapping smart insole system based on a controllable vertical pore dielectric layer10.1038/s41378-020-0171-1 ↗
12. Vibrotactile feedback improves balance and mobility in patients with severe bilateral vestibular loss10.1007/s00415-018-9133-z ↗
13. Feasibility of Lower-Limb Muscle Power Training to Enhance Locomotor Function Poststroke10.1682/JRRD.2014.04.0109 ↗
14. Beyond Statistical Significance: Embracing Minimal Clinically Important Difference for Better Patient Care10.5662/wjm.v15.i1.97814 ↗
15. Lambrich, J., Hagen, M., Schwiertz, G., and Muehlbauer, T. (2023). Concurrent Validity and Test–Retest Reliability of Pressure-Detecting Insoles for Static and Dynamic Movements in Healthy Young Adults. Sensors, 23.10.3390/s23104913 ↗
16. Cardiac Rehabilitation Increases the Reliability of the 6-Minute Walk Test in Patients After Coronary Artery Bypass Graft Surgery10.1532/hsf.1737 ↗
17. Changes Observed in the 6-Minute Walk Test in Response to Exercise-Based Cardiac Rehabilitation10.26644/em.2022.002 ↗
18. Validation of the 6 Min Walk Test According to the OMERACT Filter: A Systematic Literature Review by the EPOSS-OMERACT Group10.1136/ard.2009.120303 ↗
19. Association of Six-Minute Walk Test Distance With Postoperative Complications in Non-Cardiac Surgery: A Secondary Analysis of a Multicentre Prospective Cohort Study10.1007/s12630-020-01909-9 ↗
20. Clinical Correlates and Outcome Associated With Changes in 6-minute Walking Distance in Patients with Heart Failure: Findings From the BIOSTAT-CHF Study10.1002/ejhf.1380 ↗
21. Shimada, K. (2023). Estimation of Fast and Slow Adaptions in the Tactile Sensation of Mechanoreceptors Mimicked by Hybrid Fluid (HF) Rubber With Equivalent Electric Circuits and Properties. Sensors, 23.10.3390/s23031327 ↗
22. The Effects of Augmented Somatosensory Feedback on Postural Sway and Muscle Co-Contraction in Different Sensory Conditions10.12674/ptk.2020.27.2.126 ↗
23. Intrinsic Somatosensory Feedback Supports Motor Control and Learning to Operate Artificial Body Parts10.1088/1741-2552/ac47d9 ↗
24. Krishna, V.S.R.H., Kim, J., Chang, S.H., Choe, Y., and Park, H. (2024). Proportional Sway-Based Electrotactile Feedback Improves Lateral Standing Balance. Front. Neurosci., 18.10.3389/fnins.2024.1249783 ↗
25. Winter, L., Huang, Q., Sertic, J., and Konczak, J. (2022). The Effectiveness of Proprioceptive Training for Improving Motor Performance and Motor Dysfunction: A Systematic Review. Front. Rehabil. Sci., 3.10.3389/fresc.2022.830166 ↗
26. Clark, D.J., Hawkins, K., Winesett, S.P., Cox, B.A., Pesquera, S., Miles, J.W., Fuller, D.D., and Fox, E.J. (2022). Enhancing Locomotor Learning With Transcutaneous Spinal Electrical Stimulation and Somatosensory Augmentation: A Pilot Randomized Controlled Trial in Older Adults. Front. Aging Neurosci., 14.10.3389/fnagi.2022.837467 ↗
27. Bose, R., Petersen, B.A., Sarma, D., Barra, B., Nanivadekar, A.C., Madonna, T.J., Liu, M., Levy, I., Helm, E.R., and Miele, V. (2025). Changes in Muscle Activation and Joint Motion During Walking After Transtibial Amputation with Sensory Feedback from Spinal Cord Stimulation: A Case Study. medRxiv.10.1101/2024.12.27.24319684 ↗
28. Ravichandran, R., Patton, J.L., and Park, H. (2024). Electrotactile Proprioception Training Improves Finger Control Accuracy and Potential Mechanism Is Proprioceptive Recalibration. Sci. Rep., 14.10.1038/s41598-024-78063-5 ↗
29. Biofeedback in Partial Weight Bearing: Validity of 3 Different Devices10.2519/jospt.2016.6625 ↗
30. Lower-Extremity Weight-Bearing Compliance Is Maintained Over Time After Biofeedback Training10.3928/01477447-20121023-24 ↗
31. Bowman, T., Gervasoni, E., Arienti, C., Lazzarini, S.G., Négrini, S., Crea, S., Cattaneo, D., and Carrozza, M.C. (2021). Wearable Devices for Biofeedback Rehabilitation: A Systematic Review and Meta-Analysis to Design Application Rules and Estimate the Effectiveness on Balance and Gait Outcomes in Neurological Diseases. Sensors, 21.10.3390/s21103444 ↗
32. Effect of Age on Partial Weight-Bearing Training10.3928/01477447-20120621-23 ↗
33. COMplex Fracture Orthopedic Rehabilitation (COMFORT)—Real-Time Visual Biofeedback on Weight Bearing Versus Standard Training Methods in the Treatment of Proximal Femur Fractures in the Elderly: Study Protocol for a Multicenter Randomized Controlled Trial10.1186/s13063-018-2612-9 ↗
34. Availability and Clinical Use of Different in-Shoe Devices for Partial Weight Bearing—A Systematic Review10.24141/1/6/2/8 ↗
35. Argent, R., Slevin, P., Bevilacqua, A., Neligan, M., Daly, A., and Caulfield, B. (2019). Wearable Sensor-Based Exercise Biofeedback for Orthopaedic Rehabilitation: A Mixed Methods User Evaluation of a Prototype System. Sensors, 19.10.3390/s19020432 ↗