journal article·2025-06-07Open access

Vibration Response Characteristics of Prefabricated Frame Structures Around the Subway

Zhenyu Huang, Youfa Yang

Applied Sciences· Volume 15· Issue 12

Abstract

Prefabricated structures have gained wider application. However, there is little research on the vibration response of prefabricated frame structures in subway environments. Prolonged metro-induced vibrations may severely degrade human comfort levels for nearby residents, interfere with the operation of precision instruments, and accelerate structural fatigue damage. Consequently, it is imperative to investigate the vibration response patterns of prefabricated frame structures under metro operational conditions. Structural vibration responses demonstrated greater sensitivity to column sections and slab thickness than beam dimensions when using semirigid connections, though marginal effects emerged with parameter increases. Enhanced vibration thresholds require supplementary vibration reduction measures. Increasing total spans proved more effective in vibration reduction than adding stories, with vibration transmission exhibiting notable edge effects. Related research can provide reference for the structural design of prefabricated frame structures around the subway.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Railway Engineering and Dynamics · Structural Engineering and Vibration Analysis · Geotechnical Engineering and Underground Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Civil Engineering, Chongqing University, Chongqing 400045, China

Key Lab of Education Ministry for Construction and New Technology of Mountain Cities, Chongqing University, Chongqing 400045, China

Funding

Chongqing construction science and technology project

References (17)

Show source-provided references
1. Prediction of building vibration induced by metro trains running in a curved tunnel10.1177/1077546320930910 ↗
2. Surface ground vibration due to a moving train in a tunnel: Two dimensional model10.1006/jsvi.1999.2853 ↗
3. Research progress on prefabricated semi-rigid connection nodes of steel structures
4. Experimental Study on the Seismic Performance of Prefabricated Concrete Structure Beam-Column Assemblies in a Fully Assembled Manner
5. Experimental study on vibration table of precast concrete frame structure
6. Numerical simulation of shaking table test on a fabricated precast concrete frame structure
7. Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms10.1016/j.engstruct.2013.05.046 ↗
8. The Behavior of Different Precast Concrete Structures Under Seismic Action10.1016/j.protcy.2016.01.073 ↗
9. (2011). Code for Design of Concrete Structures (Standard No. GB50010-2010).
10. Chen, J. (2019). Research on the Coherence and Prediction of Vibration and Secondary Noise of Buildings Along the Subway Line. [Ph.D. Dissertation, Southwest Jiaotong University].
11. (2013). Allowable Vibration Standards for Construction Projects (Standard No. GB50868-2013).
12. The influence of source–receiver interaction on the numerical prediction of railway induced vibrations10.1016/j.jsv.2014.01.017 ↗
13. To the Question of Vibration Levels Prediction Inside Residential Buildings Caused by Underground Traffic10.1016/j.proeng.2017.02.334 ↗
14. The influence of subway operation on the vibration of high-rise buildings varying with the horizontal distance between building and subway tunnel and its calculation and analysis method
15. Distribution law and influencing factors of vibration inside high-rise residential buildings adjacent to subway
16. Impedance model for estimating train-induced building vibrations10.1016/j.engstruct.2018.06.032 ↗
17. Experimental study on ground vibration induced by double-line subway trains and road traffic10.1016/j.trgeo.2021.100564 ↗