journal article·2025-07-04Open access

Estimation of Cylinder Grasping Contraction Force of Forearm Muscle in Home-Based Rehabilitation Using a Stretch-Sensor Glove

Adhe Rahmatullah Sugiharto Suwito P, Ayumi Ohnishi, Tsutomu Terada, Masahiko Tsukamoto

Applied Sciences· Volume 15· Issue 13

Abstract

Monitoring forearm muscle contraction force in home-based rehabilitation remains challenging. Electromyography (EMG), as a standard technique, is considered impractical and complex for independent use by patients at home, which poses a risk of device misattachment and inaccurate recorded data. Considering the muscle-related modality, several studies have demonstrated an excellent correlation between stretch sensors and EMG, which provides significant potential for addressing the monitoring issue at home. Additionally, due to its flexible nature, it can be attached to the finger, which facilitates the logging of the kinematic mechanisms of a finger. This study proposes a method for estimating forearm muscle contraction in a cylinder grasping environment during home-based rehabilitation using a stretch-sensor glove. This study employed support vector machine (SVM), multi-layer perceptron (MLP), and random forest (RF) to construct the estimation model. The root mean square (RMS) of the EMG signal, representing the muscle contraction force, was collected from 10 participants as the target learning for the stretch-sensor glove. This study constructed an experimental design based on a home-based therapy protocol known as the graded repetitive arm supplementary program (GRASP). Six cylinders with varying diameters and weights were employed as the grasping object. The results demonstrated that the RF model achieved the lowest root mean square error (RMSE) score, which differed significantly from the SVM and MLP models. The time series waveform comparison revealed that the RF model yields a similar estimation output to the ground truth, which incorporates the contraction–relaxation phases and the muscle’s contraction force. Additionally, despite the subjectivity of the participants’ grasping power, the RF model could produce similar trends in the muscle contraction forces of several participants. Utilizing a stretch-sensor glove, the proposed method demonstrated great potential as an alternative modality for monitoring forearm muscle contraction force, thereby improving the practicality for patients to self-implement home-based rehabilitation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Muscle activation and electromyography studies · Stroke Rehabilitation and Recovery · Advanced Sensor and Energy Harvesting Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Graduate School of Engineering, Kobe University, 1-1 Rokkodaicho, Nada, Kobe 657-8501, Japan

Funding

JST Moonshot R&D Program

References (50)

Show source-provided references
1. The Balancing Act Between the Cellular Processes of Protein Synthesis and Breakdown: Exercise as a Model to Understand the Molecular Mechanisms Regulating Muscle Mass10.1152/japplphysiol.00081.2009 ↗
2. Contractile and Nutritional Regulation of Human Muscle Growth10.1097/00003677-200307000-00005 ↗
3. Management of Patients with Forearm and Hand Injuries10.18203/2349-2902.isj20201875 ↗
4. Rehabilitation for Stroke: A Review10.1161/01.STR.17.3.363 ↗
5. Home-Based Rehabilitation: Enabling Frequent and Effective Training10.1007/978-94-017-8932-5_14 ↗
6. (2024, November 20). GRASP Instructor Manuals. Available online: https://med-fom-neurorehab.sites.olt.ubc.ca/grasp-instruction-manual-2/.
7. Assessment of Force and Fatigue in Isometric Contractions of the Upper Trapezius Muscle by Surface EMG Signal and Perceived Exertion Scale10.1016/j.gaitpost.2008.04.002 ↗
8. Using Evoked EMG as a Synthetic Force Sensor of Isometric Electrically Stimulated Muscle10.1109/10.661267 ↗
9. An EMG-based Muscle Force Monitoring System10.1007/s12206-010-0616-9 ↗
10. The Relationship Between the Surface EMG and Force Transients in Muscle: Simulation and Experimental Studies10.1109/PROC.1977.10547 ↗
11. A Method of Reconstruction of the Muscular Force Profile from the EMG in the Voluntary Exercise
12. Using a Stretch Sensor to Evaluate Muscle Contraction Timing During a Neuromuscular Control Screening Activity10.1249/01.mss.0000560950.73703.87 ↗
13. O’Brien, B.M., Gisby, T., and Anderson, I. (2014, January 8). Stretch Sensors for Human Body Motion. Proceedings of the SPIE, Electroactive Polymer Actuators and Devices (EAPAD), San Diego, CA, USA.10.1117/12.2046143 ↗
14. Bifulco, P., Esposito, D., Gargiulo, G., Savino, S., Niola, V., Iuppariello, L., and Cesarelli, M. (2017, January 22–24). A Stretchable, Conductive Rubber Sensor to Detect Muscle Contraction for Prosthetic Hand Control. Proceedings of the E-Health and Bioengineering Conference (EHB), Sinaia, Romania.10.1109/EHB.2017.7995389 ↗
15. Discharge and follow-up for people with stroke: What happens and why10.1191/0269215500cr331oa ↗
16. Patient preferences for stroke rehabilitation10.1310/tsr1705-394 ↗
17. Stroke Rehabilitation at Home: Lessons Learned and Ways Forward10.1161/STROKEAHA.116.011309 ↗
18. Physical Rehabilitation Services in Disasters and Emergencies: A Systematic Review
19. Perceived risk and hazards associated with home health care among home health nurses of India10.1177/1084822319895332 ↗
20. Agent-Based Monitoring of Functional Rehabilitation Using Video Games
21. Zheng, H., Davies, R.J., and Black, N.D. (2005, January 23–24). Web-based monitoring system for home-based rehabilitation with stroke patients. Proceedings of the 18th IEEE Symposium on Computer-Based Medical Systems (CBMS’05), Dublin, Ireland.
22. Daponte, P., De Vito, L., and Sementa, C. (2013, January 4–5). A wireless-based home rehabilitation system for monitoring 3D movements. Proceedings of the 2013 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Gatineau, QC, Canada.10.1109/MeMeA.2013.6549753 ↗
23. Sassi, M., Villa Corta, M., Pisani, M.G., Nicodemi, G., Schena, E., Pecchia, L., and Longo, U.G. (2024). Advanced Home-Based Shoulder Rehabilitation: A Systematic Review of Remote Monitoring Devices and Their Therapeutic Efficacy. Sensors, 24.10.3390/s24092936 ↗
24. Measurement Tools Used in the Study of Eccentric Contraction-Induced Injury10.2165/00007256-199927010-00004 ↗
25. Force Per Active Area and Muscle Injury During Electrically Stimulated Contractions10.1249/MSS.0b013e3181757182 ↗
26. An In Vivo Rodent Model of Contraction-induced Injury and Non-invasive Monitoring of Recovery
27. Jarque-Bou, N.J., Vergara, M., and Sancho-Bru, J.L. (2024). Understanding Forearm Muscle Activity during Everyday Common Grasps: Insights for Rehabilitation, Prosthetic Control, and Human–Machine Interaction. Appl. Sci., 14.10.3390/app14083190 ↗
28. Upper Limb Muscle Forces: A Comparative Study10.1080/10255840802296913 ↗
29. Son, J., and Kim, Y. (2009, January 7–12). Development of System for Estimating Muscle Force in Real-Time. Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Munich, Germany.10.1007/978-3-642-03889-1_71 ↗
30. Du, Y., Yao, W., Wang, H., Xie, P., Qiu, S., Zhang, N., Zhang, J., and Xie, B. (December, January 30). Research on An Method of Muscle Force Prediction Based on Dynamic Fuzzy Neural Network. Proceedings of the Chinese Automation Congress (CAC), Xi’an, China.
31. Muscle Activity Monitoring with Fabric Stretch Sensors10.1007/s12221-017-7042-x ↗
32. Towards Soft Wearable Strain Sensors for Muscle Activity Monitoring10.1109/TNSRE.2022.3196501 ↗
33. Lin, Y.-A., Mhaskar, Y., Silder, A., Sessoms, P.H., Fraser, J.J., and Loh, K.J. (2022). Muscle Engagement Monitoring Using Self-Adhesive Elastic Nanocomposite Fabrics. Sensors, 22.10.3390/s22186768 ↗
34. Wang, Y., Zheng, L., Yang, J., and Wang, S. (2022). A Grip Strength Estimation Method Using a Novel Flexible Sensor under Different Wrist Angles. Sensors, 22.10.3390/s22052002 ↗
35. Dahiya, A.S., Gil, T., Azemard, N., Thireau, J., Lacampagne, A., Todri-Sanial, A., and Charlot, B. (2020, January 15–26). Stretchable strain sensors for human movement monitoring. Proceedings of the 2020 Symposium on Design, Test, Integration & Packaging of MEMS and MOEMS (DTIP), Lyon, France.10.1109/DTIP51112.2020.9139154 ↗
36. Sbernini, L., Pallotti, A., and Saggio, G. (2016, January 15–18). Evaluation of a Stretch Sensor for its inedited application in tracking hand finger movements. Proceedings of the 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Benevento, Italy.10.1109/MeMeA.2016.7533809 ↗
37. Wu, Y., Beker, L., Karakurt, I., Cai, W., Elwood, J., Li, X., Zhong, J., Zhang, M., Wang, X., and Lin, L. (2017, January 18–22). High resolution flexible strain sensors for biological signal measurements. Proceedings of the 2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), Kaohsiung, Taiwan.10.1109/TRANSDUCERS.2017.7994255 ↗
38. (2025, March 20). Flexible Stretch Sensor. Available online: https://www.imagesco.com/sensors/stretch-sensor.html.
39. (2025, March 20). MindRove Armband EMG. Available online: https://mindrove.com/armband/.
40. (2025, March 20). Muscles in the Posterior Compartment of the Forearm. Available online: https://teachmeanatomy.info/upper-limb/muscles/posterior-forearm/.
41. (2025, February 08). Practical Guide to Data Smoothing and Filtering. Available online: http://isbweb.org/software/sigproc/bogert/filter.pdf.
42. Xin, Q., Yahya, N., Izhar, L.I., Xie, P., Qiu, S., Zhang, N., Zhang, J., and Xie, B. (2019, January 14). Classification of Neurological States from Biosensor Signals Based on Statistical Features. Proceedings of the 2019 IEEE Student Conference on Research and Development (SCOReD), Bandar Seri Iskandar, Malaysia.10.1109/SCORED.2019.8896286 ↗
43. Inertial Measurement Unit-Based Functional Evaluation for Adhesive Capsulitis Assessment
44. EMG normalization: Considerations of the literature for muscular function evaluation
45. EMG normalization method based on grade 3 of manual muscle testing: Within-and between-day reliability of normalization tasks and application to gait analysis10.1016/j.gaitpost.2017.10.026 ↗
46. Ali, A.M.M., Yusof, Z.M.D., Kushairy, A.K., Zaharah, H.F., and Ismail, A. (2015, January 8). Development of Smart Glove system for therapy treatment. Proceedings of the 2015 International Conference on BioSignal Analysis, Processing and Systems (ICBAPS), Kuala Lumpur, Malaysia.
47. Design and development of a sensored glove for home-based rehabilitation10.1016/j.jht.2020.03.023 ↗
48. Imtiaz, S., Humyra, R., Sharar Kashem, M.R., Khan, M.F., Hossain, M.S., and Kabir, M.H. (2024, January 27). Rehabilitation For Stroke Survivors: The Development of a Smart Glove. Proceedings of the 2023 26th International Conference on Computer and Information Technology (ICCIT), Cox’s Bazar, Bangladesh.10.1109/ICCIT60459.2023.10441307 ↗
49. Home-based hand rehabilitation with a robotic glove in hemiplegic patients after stroke: A pilot feasibility study10.1080/10749357.2017.1389021 ↗
50. Self-directed arm therapy at home after stroke with a sensor-based virtual reality training system10.1186/s12984-016-0182-1 ↗