Comparison Between Titanium and Thermally Activated Prostheses in Stapes Surgery
Source abstract
Abstract
This study investigates hearing outcomes of stapedotomy using two different types of prostheses: manually crimped MatriX and thermally activated NiTiBOND. The primary objective was to determine whether the method of prosthesis fixation to the long process of incus influences postoperative results. A retrospective analysis was conducted on 155 patients with otosclerosis; 90 received the NiTiBOND prosthesis and 65 received the MatriX prosthesis. Choice of prosthesis was determined intraoperatively based on position of chorda tympani. If the nerve was located near the incus and the prosthesis fixation site, the surgeon opted for MatriX prosthesis to avoid potential injury from activation of the NiTiBOND. Audiometric evaluations revealed no statistically significant differences in bone conduction thresholds on the first postoperative day (p = 0.275) or at six weeks (p = 0.899), postoperative air-bone gap (p = 0.810), air-bone gap closure (p = 0.489), overclosure (p = 0.436), or bone conduction at 4 kHz (p = 0.324). Chorda tympani nerve injury occurred in 9.2% of cases with MatriX prosthesis and 6.7% with NiTiBOND prosthesis (p = 0.556). Our findings highlight the theoretical and practical significance of comparing both prostheses, demonstrating that NiTiBOND can serve as an alternative in anatomically favorable cases, thereby guiding treatment choices.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Reconstructive Surgery and Microvascular Techniques · Reconstructive Facial Surgery Techniques · Surgical Sutures and Adhesives
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Medicine, University of Maribor, 2000 Maribor, Slovenia
Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Centre Maribor, 2000 Maribor, Slovenia
References (19)
Show source-provided references
1. Influence of angular positioning of the prosthesis in stapes surgeries with a NiTiBond prosthesis: Investigation in cadaveric temporal bones10.1016/j.heares.2019.01.005 ↗
2. Heinz KURZ GmbH Medizintechnik (2025, April 11). Passive Middle Ear Implants; Ventilation Tubes, Surgical Instruments; 2022. Available online: https://epaper.kurzmed.de/epaper-en.html.
3. Otosclerosis: Temporal Bone Pathology10.1016/j.otc.2017.11.001 ↗
4. Otosclerosis-analysis of factors influencing the improvement of hearing after surgical treatment10.5604/01.3001.0015.8248 ↗
5. How Long Is Otosclerosis Surgery Effective? Hearing Results after a 22-Year Follow-Up10.1159/000509106 ↗
6. Early functional results using the nitibond prosthesis in stapes surgery10.1080/00016489.2016.1247499 ↗
7. The Stapes Prosthesis: Past, Present, and Future10.1016/j.otc.2017.11.010 ↗
8. Stapes surgery: How precisely do different prostheses attach to the long process of the incus with different instruments and different surgeons?10.1097/00129492-200205000-00010 ↗
9. Laser-assisted fixation of a nitinol stapes prosthesis10.1002/lsm.22738 ↗
10. Achena, A., Pacelli, L., Prizio, C., Mantini, G., Placentino, A., Accorona, R., Valenzise, V., Pilolli, F., Ormellese, G.L., and Mevio, N. (2025). Nitinol Prosthesis in Stapes Surgery: Evolution from Heat-Activated to Superelastic Nitinol: A Systematic Review. J. Clin. Med., 14.10.3390/jcm14041069 ↗
11. Hearing results after stapedotomy for otosclerosis: Comparison of prosthesis variables10.1017/S0022215120002595 ↗
12. An analysis of the air-bone gap closure obtained by a crimping and a non-crimping titanium stapes prosthesis in otosclerosis10.1016/j.anl.2007.04.007 ↗
13. Committee on Hearing and Equilibrium (1995). Committee on Hearing and Equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. Otolaryngol. Head Neck Surg., 113, 186–187.10.1016/S0194-5998(95)70103-6 ↗
14. lmerTest Package: Tests in Linear Mixed Effects Models10.18637/jss.v082.i13 ↗
15. R Core Team (2025, May 10). R: A Language and Environment for Statistical Computing (Version 4.4.3). Available online: https://www.R-project.org/.
16. Evaluating hearing results in stapedotomy: Comparison of fluoroplastic Causse loop piston and Matrix prosthesis10.1002/lio2.675 ↗
17. Clinical evaluation of the NiTiBOND stapes prosthesis, an optimized shape memory alloy design10.1097/MAO.0b013e31823e28cb ↗
18. Comparison of manually crimping and laser-activated nitinol prosthesis in otosclerosis surgery: Our experience of 98 patients10.1111/coa.12622 ↗
19. How to Avoid a Learning Curve in Stapedotomy: A Standardized Surgical Technique10.1097/MAO.0000000000001475 ↗