Comparative Thermal Ageing Analysis of Ester Dielectric Fluids Impregnating TUK Paper: Implications for Transformer Maintenance Standards
Source abstract
Abstract
The increasing demand for electricity and the requirement for transformers to operate under higher loads have driven the search for new insulating materials. On the one hand, papers with enhanced thermal resistance, such as thermally upgraded kraft (TUK) papers, are being introduced; on the other, the use of ester liquids is gaining attention due to their thermal and environmental advantages. This study investigates the thermal ageing behaviour of TUK paper impregnated with five ester liquids—four natural liquids of different origin and one synthetic—subjected to accelerated ageing at 130 °C, 150 °C, and 170 °C, and compared with mineral oil as impregnating fluid as a reference. The degradation of the paper, assessed through its degree of polymerisation, was monitored alongside the evolution of key chemical, physical, and dielectric properties of the liquids. In addition to the experimental analysis, this work also examines the current maintenance standards applied to transformers operating with different insulating fluids. The results showed that while the paper degradation was similar across most of the esters, the ageing behaviour of the fluids differed significantly in terms of acidity, moisture content, interfacial tension, and dielectric dissipation factor. These discrepancies strongly influence the interpretation of fluid condition based on existing transformer maintenance standards, which may lead to inconsistent assessments when applied to ester-filled transformers. The findings highlight both the suitability of natural esters for high-temperature operation and the need to revisit condition assessment criteria in standards that were originally developed for mineral oil systems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Transformer Diagnostics and Insulation · High voltage insulation and dielectric phenomena · Electrical Fault Detection and Protection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical and Energy Engineering, Universidad de Cantabria, 39005 Santander, Spain
Funding
Spanish State Research Agency
References (75)
Show source-provided references
1. Jørgensen, B.N., and Ma, Z.G. (2025). Digital Twin of the European Electricity Grid: A Review of Regulatory Barriers, Technological Challenges, and Economic Opportunities. Appl. Sci., 15.10.3390/app15126475 ↗
2. Cavus, M. (2025). Advancing Power Systems with Renewable Energy and Intelligent Technologies: A Comprehensive Review on Grid Transformation and Integration. Electronics, 14.10.3390/electronics14061159 ↗
3. A Critical Review of Plant-Based Insulating Fluids for Transformer: 30-Year Development10.1016/j.rser.2021.110783 ↗
4. Oparanti, S.O., Obebe, E.O., Fofana, I., and Jafari, R. (2025). A State-of-the-Art Review on the Potential of Waste Cooking Oil as a Sustainable Insulating Liquid for Green Transformers. Appl. Sci., 15.10.3390/app15147631 ↗
5. Bertagnolli, G. (2014). Power Transformers & Short Circuits: Evaluation of the Short-Circuit Performance of Power Transformers, ABB Limited Transformers.
6. Power Transformer Insulation—History, Technology and Design10.1109/TDEI.2012.6396951 ↗
7. V Cellulose Insulation in Oil-Filled Power Transformers: Part I—History and Development10.1109/MEI.2006.1618969 ↗
8. Cigre Working Group D1.53 (2018). Materials and Emerging Test Techniques—Ageing of Liquid Impregnated Cellulose for Power Transformers, CIGRE.
9. Lundgaard, L.E., Allan, D., Höhlein, I.A., Clavreul, R., Dahlund, M.O., Gasser, H.P., Heywood, R., Krause, C., Lessard, M.C., and Saha, T.K. (2007). Ageing of Cellulose in Mineral-Oil Insulated Transformers, CIGRE.
10. 50 Years in the Development of Insulating Liquids10.1109/MEI.2013.6585853 ↗
11. Mineral Oil in Transformers10.1109/57.675572 ↗
12. Harlow, J.H. (2003). Electric Power Transformer Engineering, CRC Press.10.1201/9780203486481 ↗
13. Berger, N., Randoux, M., Ottmann, G., and Vuarchez, P. (2025, October 23). Review on Insulating Fluids. Electra, Available online: https://www.e-cigre.org/publications/detail/elt-171-2-review-on-insulating-liquids.html.
14. Use of Vegetable Oils as Transformer Oils—A Review10.1016/j.rser.2015.07.032 ↗
15. Oparanti, S.O., Rao, U.M., and Fofana, I. (2023). Natural Esters for Green Transformers: Challenges and Keys for Improved Serviceability. Energies, 16.10.3390/en16010061 ↗
16. Ahmad, M., Daris, I., Rahmat, H., and Suprijadi, S. (2021, January 5–6). Aging Behavior of Mineral Oil, Gas-to-Liquid (GTL), and Natural Ester Liquids in Presence of Cellulosic Materials. Proceedings of the 2021 3rd International Conference on High Voltage Engineering and Power Systems (ICHVEPS), Bandung, Indonesia.10.1109/ICHVEPS53178.2021.9601042 ↗
17. Rapp, K.J., and Luksich, J. (July, January 29). Accelerated Aging of Aramid Insulation in Various Dielectric Liquids. Proceedings of the 2014 IEEE 18th International Conference on Dielectric Liquids, ICDL 2014, Bled, Slovenia.10.1109/ICDL.2014.6893123 ↗
18. Reducing Environmental Impact and Improving Safety and Performance of Power Transformers with Natural Ester Dielectric Insulating Fluids10.1109/TIA.2013.2269532 ↗
19. Rozga, P., Beroual, A., Przybylek, P., and Jaroszewski, M. (2020). A Review on Synthetic Ester Liquids for Transformer Applications. Energies, 13.10.3390/en13236429 ↗
20. Nogueira, T., Carvalho, J., and Magano, J. (2022). Eco-Friendly Ester Fluid for Power Transformers versus Mineral Oil: Design Considerations. Energies, 15.10.3390/en15155418 ↗
21. The Role of Ester Fluids in Europe’s Ageing Grid
22. A Review on Transformer Condition Monitoring with Critical Investigation of Mineral Oil and Alternate Dielectric Fluids10.1016/j.epsr.2022.108954 ↗
23. Compatibility of Transformer Construction Materials with Natural Ester-Based Insulating Fluids10.1109/TDEI.2015.004755 ↗
24. Mužík, M., Trnka, P., Hornak, J., Michal, O., and Mentlik, V. (2020, January 1–4). Compatibility of Polymer Materials with Natural-Based Insulation Oils. Proceedings of the International Conference on Diagnostics in Electrical Engineering (Diagnostika), Pilsen, Czech Republic.10.1109/Diagnostika49114.2020.9214769 ↗
25. (2013). Mineral Insulating Oils in Electrical Equipment—Supervision and Maintenance Guidance (Standard No. IEC 60422:2013).
26. Sidthik, A.S., and Ravindran, M. (2021, January 27–29). Typical Analysis of Different Natural Esters and Their Performance: A Review. Proceedings of the 2021 Innovations in Power and Advanced Computing Technologies (i-PACT), Kuala Lumpur, Malaysia.10.1109/i-PACT52855.2021.9696578 ↗
27. Degradation of Cellulosic Insulation in Power Transformers. Part 3: Effects of Oxygen and Water on Ageing in Oil10.1049/ip-smt:20000021 ↗
28. Ageing Rate of Paper Insulation Used in Power Transformers Part 1: Oil/Paper System with Low Oxygen Concentration10.1109/TDEI.2012.6396958 ↗
29. Ageing Rate of Paper Insulation Used in Power Transformers Part 2: Oil/Paper System with Medium and High Oxygen Concentration10.1109/TDEI.2012.6396960 ↗
30. Aging Behavior of Cellulosic Materials in Presence of Mineral Oil and Ester Liquids under Various Conditions10.1109/TDEI.2013.6678843 ↗
31. Mendez, C. (2023). Degradation Assessment of the Insulating Materials in Transformers Immersed in Biodegradable Liquids. [Ph.D. Thesis, Universidad de Cantabria].
32. Rapp, K.J., and Luksich, J. (2011, January 26–30). Review of Kraft Paper/Natural Ester Fluid Insulation System Aging. Proceedings of the 2011 IEEE International Conference on Dielectric Liquids, Trondheim, Norway.10.1109/ICDL.2011.6015464 ↗
33. Brahami, Y., Oparanti, S.O., Fofana, I., and Fethi, M. (2025). Thermal and Electrical Fault Diagnosis in Oil–Paper Insulation System: A Comparative Study of Natural Esters and Mineral Oil. Appl. Sci., 15.10.3390/app15147676 ↗
34. Understanding the Ageing Performance of Alternative Dielectric Fluids10.1109/ACCESS.2023.3239895 ↗
35. (2015). Insulating Fluids—Mineral Oil Working Group IEEE C57.106-2015: IEEE Guide for Acceptance and Maintenance of Insulating Mineral Oil in Electrical Equipment (Standard No. WGC57.106).
36. (2021). Natural Esters—Guidelines for Maintenance and Use in Electrical Equipment (Standard No. IEC 62975).
37. (2025). Synthetic Organic Esters for Electrical Purposes—Guide for Maintenance of Transformer Esters in Equipment (Standard No. IEC 61203).
38. Méndez, C., Olmo, C., Antolín, I., Ortiz, A., and Renedo, C.J. (2024). Analysing the Suitability of Using Different Biodegradable Fluids for Power Transformers with Thermally Upgraded Paper. Sustainability, 16.10.3390/su16083259 ↗
39. (2004). Specification for Pressboard and Presspaper for Electrical Purposes—Part 2: Methods of Test (Standard No. IEC 60641).
40. (2017). Paper and Board—Determination of Moisture Content of a Lot—Oven-Drying Method (Standard No. ISO 287).
41. (2013). Electric Strength of Insulating Materials—Test Methods—Part 1: Tests at Power Frequencies (Standard No. IEC 60243).
42. (1998). Crude Petroleum and Liquid Petroleum Products—Laboratory Determination of Density—Hydrometer Method (Standard No. ISO 3675).
43. (2017). Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Standard No. ASTM D445).
44. (2017). Petroleum and Related Products—Determination of Flash and Fire Points—Cleveland Open Cup Method (Standard No. ISO 2592).
45. (2020). Petroleum and Related Products from Natural or Synthetic Sources—Determination of Pour Point (Standard No. ISO 3016).
46. (2014). Insulating Liquids—Determination of Acidity—Part 3: Test Methods for Non-Mineral Insulating Oils (Standard No. IEC 62021.3).
47. (1997). Insulating Liquids—Oil-Impregnated Paper and Pressboard—Determination of Water by Automatic Coulometric Karl Fischer Titration (Standard No. IEC 60814).
48. (2004). Insulating Liquids—Measurement of Relative Permittivity, Dielectric Dissipation Factor (Tan d) and d.c. Resistivity (Standard No. IEC 60247).
49. (2018). Insulating Liquids—Determination of the Breakdown Voltage at Power Frequency—Test Method (Standard No. IEC 60156).
50. OECD 301B (2025, October 23). Ready Biodegradability. Available online: https://www.aropha.com/biodegradable-testing-labs/oecd-301b/.
51. Comparative Analysis of Moisture Removing Processes from Transformer Which Are Used to Increase Its Efficiency
52. (2012). Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers (Standard No. IEEE Standard C57.100).
53. (2004). Measurement of the Average Viscometric Degree of Polymerization of New and Aged Cellulosic Electrically Insulating Materials (Standard No. IEC 60450).
54. (2003). Insulating Liquids—Determination of Acidity—Part 1: Automatic Potentiometric Titration (Standard No. IEC 62021).
55. (2018). Insulating Liquids—Test Methods for the Determination of Interfacial Tension of Insulating Liquids—Determination with the Ring Method (Standard No. IEC 62961).
56. (2012). Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity) (Standard No. ASTM D7042).
57. (2016). Determination of Flash Point—Pensky-Martens Closed Cup Method (Standard No. ISO 2719).
58. Comparative Study of the Thermal Degradation of Synthetic and Natural Esters and Mineral Oil: Effect of Oil Type in the Thermal Degradation of Insulating Kraft Paper10.1109/MEI.2012.6159178 ↗
59. Aging Assessment of Synthetic Ester Impregnated Thermally Non-Upgraded Kraft Paper through Chemical Markers in Oil10.1109/TDEI.2018.006833 ↗
60. A Survey of Aging Characteristics of Cellulose Insulation in Natural Ester and Mineral Oil10.1109/MEI.2011.6025367 ↗
61. Alternative Dielectric Fluids for Transformer Insulation System: Progress, Challenges, and Future Prospects10.1109/ACCESS.2019.2960020 ↗
62. Comparative Studies on the Aging of Thermally Upgraded Paper Insulation in Palm Fatty Acid Ester, Mineral Oil, and Natural Ester10.1109/TDEI.2015.005502 ↗
63. Moisture Dynamics in Natural-Ester Filled Transformers10.1016/j.ijepes.2020.106172 ↗
64. Moisture Diffusion Coefficients of Transformer Pressboard Insulation Impregnated with Natural Esters10.1109/TDEI.2014.004620 ↗
65. Various Aging Processes in a Paper-Natural Ester Insulation System in the Presence of Copper and Moisture10.1109/ACCESS.2020.2983907 ↗
66. Understanding the Ageing Aspects of Natural Ester Based Insulation Liquid in Power Transformer10.1109/TDEI.2015.004744 ↗
67. Münster, T., Werle, P., Hämel, K., and Preusel, J. (2021). Thermally Accelerated Aging of Insulation Paper for Transformers with Different Insulating Liquids. Energies, 14.10.3390/en14113036 ↗
68. Forouhari, S., and Abu-Siada, A. (2015, January 19–22). Remnant Life Estimation of Power Transformer Based on IFT and Acidity Number of Transformer Oil. Proceedings of the IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM), Sydney, NSW, Australia.10.1109/ICPADM.2015.7295331 ↗
69. Aging Performance and Moisture Solubility of Vegetable Oils for Power Transformers10.1109/TPWRD.2009.2034747 ↗
70. Oxidation Stability Assessment of a Vegetable Transformer Oil under Thermal Aging10.1109/TDEI.2013.004073 ↗
71. Mustafa, E., Ahmad, B., Ali, M.I., Afia, R.S.A., and Ullah, R. (2024). Degradation Assessment of In-Service Transformer Oil Based on Electrical and Chemical Properties. Appl. Sci., 14.10.3390/app142411767 ↗
72. A Comparative Study of Thermal Aging of Transformer Insulation Paper Impregnated in Natural Ester and in Mineral Oil10.1002/etep.336 ↗
73. Gasser, H.P., Krause, C., Lashbrook, M., and Martin, R. (2011, January 26–30). Aging of Pressboard in Different Insulating Liquids. Proceedings of the 2011 IEEE International Conference on Dielectric Liquids, Trondheim, Norway.10.1109/ICDL.2011.6015450 ↗
74. Ariffin, M.M., Ishak, M.T., Hamid, M.H.A., Katim, N.I.A., Ishak, A., and Azis, N. (2017, January 2–5). Ageing Effect of Vegetable Oils Impregnated Paper in Transformer Application. Proceedings of the International Conference on High Voltage Engineering and Power Systems, ICHVEPS 2017, Denpasar, Indonesia.10.1109/ICHVEPS.2017.8225939 ↗
75. Prevost, T.A. (2009, January 26–30). Dielectric Properties of Natural Esters and Their Influence on Transformer Insulation System Design and Performance—An Update. Proceedings of the 2009 IEEE Power & Energy Society General Meeting, Calgary, AB, Canada.10.1109/PES.2009.5275167 ↗