journal article·2020-09-04Open access

A Conceptual Investigation at the Interface between Wireless Power Devices and CMOS Neuron IC for Retinal Image Acquisition

AlaaDdin Al-Shidaifat, Sandeep Kumar, Shubhro Chakrabartty, Hanjung Song

Applied Sciences· Volume 10· Issue 18

Abstract

In this paper, a conceptual investigation of the interface between wireless power devices and a retina complementary metal oxide semiconductor (CMOS) neuron integrated circuit (IC) have been presented. The proposed investigation consists of three designs: design-I, design-II, and design-III. Design-I involves a slotted loop monopole antenna as per American National Standards Institute (ANSI) guidelines, which achieve an ultra-wide band ranging from 3.1 GHz to 10.6 GHz. The biocompatible antenna is made on silicon-nitride substrate using on-wafer packaging technology and it is used as a receiver device. The performance of antenna provides a wideband, sufficient power to receive, and low losses due to the avoidance of printed circuit board (PCB) fabrication. A CMOS based multi-stack power harvesting circuit achieves the output power ranging from 4 mW to 2.7 W and corresponds from the selected Radio Frequency (RF) bands of loop antenna is exhibited in design-II. The power efficiency of 40% to 82%, with respect to output powers of 4 mW to 2.7 W, is achieved. Design-III includes a CMOS based retina neuron circuit that employs a dynamic feedback technique and support to achieve the number of read-out spikes. At the end of the interface between wireless power devices and a CMOS retina neuron IC, 50 mV read-out spikes are achieved, with varying light intensity, from 0 mW/cm2 to 2 mW/cm2. The proposed design-II and design-III are implemented and fabricated using commercial CMOS 0.065 µm, Samsung process. The antenna and RF power harvesting IC could be placed on a contact lens platform while retina neuron IC can be implanted after ganglions cells inside the eye. The antenna and harvesting IC are physically connected to the retina circuit in the form of light. This conceptual investigation could support medical professionals in achieving an interfacing approach to restore the image visualization.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Photoreceptor and optogenetics research · Retinal Development and Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Nanoscience and Engineering, Centre for Nano Manufacturing, Inje University Gimhae, Gimhae 50834, Korea

Department of Electronics and Communication Engineering, National Institute of Technology Karnataka, Surathkal, Mangaluru, Karnataka 575025, India

Funding

The Ministry of Education, Science and Technology, Korea

References (28)

Show source-provided references
1. Photovoltaic retinal prosthesis with high pixel density10.1038/nphoton.2012.104 ↗
2. The implantable miniature telescope for macular degeneration10.1097/01.icu.0000193067.86627.a1 ↗
3. Voltage regulation of retina neuron model with dynamic feedback for biological acquisition image10.1007/s13206-017-1406-6 ↗
4. Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants10.1109/TCSI.2005.852923 ↗
5. A modular 32-site wireless neural stimulation microsystem10.1109/JSSC.2004.837026 ↗
6. A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode10.1109/4.654942 ↗
7. Liu, W., and Humayun, M.S. (2004, January 15–19). Retinal prosthesis. Proceedings of the IEEE International Solid-State Circuits Conference Digest Technical Papers, San Francisco, CA, USA.
8. A 232-channel epiretinal stimulator ASIC10.1109/JSSC.2007.908693 ↗
9. An integrated 256-channel epiretinal prosthesis10.1109/JSSC.2010.2055371 ↗
10. A hermetic wireless subretinal neurostimulator for vision prostheses10.1109/TBME.2011.2165713 ↗
11. Gd-Doped HfO 2 Memristor Device, Evaluation Robustness by Image Noise Cancellation and Edge Detection Filter for Neuromorphic Computing10.1109/ACCESS.2019.2950080 ↗
12. Jung, L.H., Shany, N., Lehmann, T., Preston, P., Lovell, N.H., and Suaning, G.J. (September, January 30). Towards a chip scale neurostimulator: System architecture of a current-driven 98 channel neurostimulator via a two-wire inter-face. Proceedings of the International Conference IEEE Engineering in Medicine and Biology Society, Boston, MA, USA.
13. Subretinal electronic chips allow blind patients to read letters and combine them to words10.1098/rspb.2010.1747 ↗
14. Development and in-vivo demonstration of CMOS-based multichip retinal stimulator with simultaneous multisite stimulation capability10.1109/TBCAS.2010.2078508 ↗
15. Chen, K., Lo, Y.-K., and Liu, W. (2013, January 17–21). A 37.6mm2 1024-channel high-compliance voltage SoC for epiretinal prostheses. Proceedings of the IEEE International Solid-State Circuits Conference Digest Technical Papers, San Francisco, CA, USA.
16. Al-Shidaifat, A., Chakrabartty, S., Kumar, S., Acharjee, S., and Song, H. (2020). A Novel Characterization and Performance Measurement of Memristor Devices for Synaptic Emulators in Advanced Neuro-Computing. Micromachines, 11.10.3390/mi11010089 ↗
17. Monge, M., Raj, M., Honarvar-Nazari, M., Chang, H.C., Zhao, Y., Weiland, J., Humayun, M., Tai, Y., and Emami-Neyestanak, A. (2013, January 17–21). A fully intraocular 0.0169 mm2/pixel 512-channel self-calibrating epiretinal prosthesis in 65nm CMOS. Proceedings of the IEEE International Solid-State Circuits Conference Digest Technical Papers, San Francisco, CA, USA.10.1109/ISSCC.2013.6487742 ↗
18. Mokwa, W., Goertz, M., Koch, C., Krisch, I., Trieu, H.-K., and Walter, P. (2008, January 20–25). Intraocular epiretinal prosthesis to restore vision in blind humans. Proceedings of the International Conference IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.10.1109/IEMBS.2008.4650530 ↗
19. A soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring10.1109/SENSOR.2003.1216947 ↗
20. A programmable intraocular CMOS pressure sensor system implant10.1109/4.933466 ↗
21. Cong, H., and Pan, T. (2009, January 5–8). Microfabrication of conductive PDMS on flexible substrates for biomedical applications. Proceedings of the IEEE International Conference Nano/Micro Engineered and Molecular Systems, Shenzhen, China.10.1109/NEMS.2009.5068682 ↗
22. Optimization of data coils in a multiband wireless link for neuroprosthetic implantable devices10.1109/TBCAS.2010.2049491 ↗
23. A 128-channel 6mW wireless neural recording IC with spike feature extraction and UWB transmitter10.1109/TNSRE.2009.2021607 ↗
24. Zamani, H., and Mohseni, P. (September, January 30). A high-speed circuit architecture for IR-UWB transmission off ast-scan cyclic voltammetry in 0.35µm CMOS. Proceedings of the IEEE Annual International Conference Engineering in Medicine and Biology Society, Buenos Aires, Argentina.
25. Razavi, B. (2000). Design of Analog CMOS Integrated Circuits, McGraw-Hill.
26. Selection and optimization of temporal spike encoding methods for spiking neural networks
27. A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural Prostheses10.1109/TBCAS.2013.2297695 ↗
28. Kang, H., Abbasi, W.H., Kim, S.-W., and Kim, J. (2019). Fully Integrated Light-Sensing Stimulator Design for Subretinal Implants. Sensors, 19.10.3390/s19030536 ↗