journal article·2020-12-18Open access

Simplified Calibration Method for Constant-Temperature Hot-Wire Anemometry

Hidemi Takahashi, Mitsuru Kurita, Hidetoshi Iijima, Seigo Koga

Applied Sciences· Volume 10· Issue 24

Abstract

This study proposes a unique approach to convert a voltage signal obtained from a hot-wire anemometry to flow velocity data by making a slight modification to existing temperature-correction methods. The approach was a simplified calibration method for the constant-temperature mode of hot-wire anemometry without knowing exact wire temperature. The necessary data are the freestream temperature and a set of known velocity data which gives reference velocities in addition to the hot-wire signal. The proposed method was applied to various boundary layer velocity profiles with large temperature variations while the wire temperature was unknown. The target flow velocity was ranged between 20 and 80 m/s. By using a best-fit approach between the velocities in the boundary layer obtained by hot-wire anemometry and by the pitot-tube measurement, which provides reference data, the unknown wire temperature was sought. Results showed that the proposed simplified calibration approach was applicable to a velocity range between 20 and 80 m/s and with temperature variations up to 15 °C with an uncertainty level of 2.6% at most for the current datasets.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fluid Dynamics and Turbulent Flows · Aerodynamics and Acoustics in Jet Flows · Heat Transfer Mechanisms

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research and Development Directorate, Japan Aerospace Exploration Agency, Kakuda, Miyagi 981-1525, Japan

Aeronautical Technology Directorate, Japan Aerospace Exploration Agency, Chofu, Tokyo 182-8522, Japan

References (14)

Show source-provided references
1. Review of Hot-Wire Anemometry Techniques and the Range of Their Applicability for Various Flows
2. Turbulent Intensity in Supersonic Mixing Transition by Streamwise Vortices -Fluctuation Measurements by Hot-Wire Anemometer and PIV-
3. Hot-Wire Anemometry for Superfluid Turbulent Coflows10.1063/1.4913530 ↗
4. Hot-Wire Responses in Compressible Subsonic Flow10.2514/1.J059201 ↗
5. Exploration of the Vortex Wake behind of Wind Turbine Rotor10.1088/1742-6596/75/1/012036 ↗
6. On the Convection of Heat From Small Cylinders in a Stream of Fluid: Determination of the Convection Constants of Small Platinum Wires, with Applications to Hot-Wire Anemometry10.1098/rsta.1914.0023 ↗
7. Calibration Method for A Hot Wire Anemometer10.1088/0022-3735/9/5/011 ↗
8. Temperature Corrections for Constant Temperature and Constant Current Hot-Wire Anemometers10.1088/0957-0233/21/10/105404 ↗
9. The Temperature Dependence of the Thermal Conductivity of Air
10. Takahashi, H., Iijima, H., Kurita, M., and Koga, S. (2019). Evaluation of Skin Friction Drag Reduction in the Turbulent Boundary Layer Using Riblets. Appl. Sci., 9.10.3390/app9235199 ↗
11. Inclusion of the D-optimality in multisine manoeuvre design for aircraft parameter estimation10.15632/jtam-pl.54.1.87 ↗
12. Dul, F., Lichota, P., and Rusowicz, A. (2020). Generalized Linear Quadratic Control for a Full Tracking Problem in Aviation. Sensors, 20.10.3390/s20102955 ↗
13. A New Closed-Loop Output Error Method for Parameter Identification of Robot Dynamics10.1109/TCST.2012.2185697 ↗
14. On Temperature Compensation in Hot-Wire Anemometry