journal article·2016-07-29Open access

A Self-Testing Platform with a Foreground Digital Calibration Technique for SAR ADCs

Yi-Hsiang Juan, Hong-Yi Huang, Shuenn-Yuh Lee, Shin-Chi Lai, Wen-Ho Juang, Ching-Hsing Luo

Applied Sciences· Volume 6· Issue 8

Abstract

This study presents a self-testing platform with a foreground digital calibration technique for successive approximation register (SAR) analog-to-digital converters (ADCs). A high-accuracy digital-to-analog converter (DAC) with digital control is used for the proposed self-testing platform to generate the sinusoidal test signal. This signal is then implemented using an Arduino board, and the clock signal is generated to test the ADCs. In addition, fast Fourier transform and recursive discrete Fourier transform (RDFT) processors are adopted for dynamic performance evaluation and calibration of the ADCs. The third harmonic distortion caused by the non-linearity of the track-and-hold circuit, the mismatch of the DAC capacitor array, and the direct current (DC) offset of the comparator can be calculated using the processors to improve the ADC performance. The advantages of the proposed platform include its low cost, high integration, and no need for an extra analogy compensation circuit to deal with calibration. In this work a 12 bit SAR ADC and an RDFT processor are used in the Taiwan Semiconductor Manufacturing Co., Ltd. (TSMC) 0.18 μm standard complementary metal–oxide–semiconductor (CMOS) process with a sampling rate of 18.75 kS/s to validate the proposed method. The measurement results show that the signal-to-noise and distortion ratio is 55.07 dB before calibration and 61.35 dB after calibration.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analog and Mixed-Signal Circuit Design · VLSI and Analog Circuit Testing · Advanced Electrical Measurement Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

The Department of Electrical Engineering, National Cheng Kung University, Tainan 701, Taiwan

The Department of Electrical Engineering, National Taipei University, Taipei, 23741, Taiwan

The Department of Computer Science and Information Engineering, Nanhua University, Chiayi 62249, Taiwan

References (14)

Show source-provided references
1. A 1-V 450-nW fully integrated programmable biomedical sensor interface chip10.1109/JSSC.2009.2014707 ↗
2. Afully integrated SAR ADC using digital correction technique for triple-mode mobile transceiver10.1109/JSSC.2014.2357436 ↗
3. A state of the art on ADC error compensation methods10.1109/TIM.2005.851083 ↗
4. Tester-assisted calibration and screening for digitally-calibrated ADCs10.1109/TCSI.2011.2158706 ↗
5. Methodology and measurement setup for analog-to-digital converter postcompensation10.1109/TIM.2013.2295877 ↗
6. IRD digital background calibration of SAR ADC with coarse reference ADC acceleration
7. Liang, M.C., Hsieh, C.H., and Lee, S.Y. (2013, January 19–23). A 1.5-bit/stage pipelined ADC with FFT-based calibration method. Proceedings of the 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013), Beijing, China.
8. A distortion cancelation technique with the recursive DFT method for successive approximation analog-to-digital converter
9. Adaptive successive approximation ADC for biomedical acquisition system10.1016/j.mejo.2013.06.015 ↗
10. Burns, M., and Roberts, G.W. (2001). An introduction to mixed-signal IC test and measurement, Oxford University Press.
11. Low computational complexity, low power, and low area design for the implementation of recursive DFT and IDFT algorithms
12. Built-in self-calibration and digital-trim technique for 14-bit SAR ADCs achieve ±1 LSB INL10.1109/TVLSI.2014.2321761 ↗
13. Digitally calibrated 768-kS/s 10-b minimum-size SAR ADC array with dithering10.1109/JSSC.2012.2198350 ↗
14. A digital-domain calibration of split-capacitor DAC for a differential SAR ADC without additional analog circuits10.1109/TCSI.2013.2252475 ↗