journal article·2018-09-07Open access

Planning Lung Radiotherapy Incorporating Motion Freeze PET/CT Imaging

Shih-Neng Yang, Wan-Chi Chiang, Kuei-Ting Chou, Geoffrey Zhang, Tzung-Chi Huang

Applied Sciences· Volume 8· Issue 9

Abstract

Motion Freeze (MF), which integrates 100% of the signal of each respiratory phase in four-dimensional positron emission tomography (4D-PET) images and creates the MF-PET, is capable of eliminate the influences induced by respiratory motion and dispersing from three-dimensional PET (3D-PET) and 4D-PET images. In this study, the effectiveness of respiratory gated radiotherapy applying MF-PET (MF-Plan) in lung cancer patient was investigated and compared with three-dimensional intensity modulated radiotherapy (3D-Plan) and routine respiratory gated radiotherapy (4D-Plan) on the impact of target volume and dosimetry. Thirteen lung cancer patients were enrolled. The internal target volumes were generated with 40% of maximum standardized uptake value. The 3D-Plan, 4D-Plan, and MF-Plan were created for each patient to study the radiation to the targets and organs at risk. MF-Plans were associated with significant reductions in lung, heart, and spinal cord doses. The median reductions in lung V20, lung mean, heart mean doses, and spinal cord maximum dose compared with 3D-Plans were improved. When compared with 4D-Plans, the median reductions in lung V20, lung mean dose, heart mean dose, and spinal cord maximum dose were improved. Our results indicate that the MF-Plan may improve critical organ sparing in the lung, heart, and spinal cord, while maintaining high target coverage.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications · Radiation Therapy and Dosimetry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung 40402, Taiwan

Department of Medical Imaging, Chang Bing Show Chwan Memorial Hospital, Changhua 50544, Taiwan

Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL 33612, USA

Department of Bioinformatics and Medical Engineering, Asia University, Taichung 41354, Taiwan

AI Center for Medical Diagnosis, China Medical University Hospital, Taichung 40402, Taiwan

Funding

China Medical University Hospital · Chang Bing Show Chwan Memorial Hospital

References (17)

Show source-provided references
1. The management of respiratory motion in radiation oncology report of AAPM Task Group 7610.1118/1.2349696 ↗
2. Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients10.1016/j.ijrobp.2007.11.042 ↗
3. Minimal benefit of respiratory-gated radiation therapy in the management of thoracic malignancy10.1111/1754-9485.12088 ↗
4. Generating lung tumor internal target volumes from 4D-PET maximum intensity projections10.1118/1.3633896 ↗
5. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images10.1088/0031-9155/53/13/018 ↗
6. Comparative evaluation of CT-based and respiratory-gated PET/CT-based planning target volume (PTV) in the definition of radiation treatment planning in lung cancer: Preliminary results10.1007/s00259-013-2594-5 ↗
7. Clinical utility of 4D FDG-PET/CT scans in radiation treatment planning10.1016/j.ijrobp.2010.12.060 ↗
8. Motion freeze for respiration motion correction in PET/CT: A preliminary investigation with lung cancer patient data10.1155/2014/167491 ↗
9. Determining optical flow10.1016/0004-3702(81)90024-2 ↗
10. Determining parameters for respiration-gated radiotherapy10.1118/1.1406524 ↗
11. [Volume-effect and radiotherapy [II]. Part II: Volume-effect and normal tissue]10.1016/S1278-3218(03)00082-9 ↗
12. Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: Final report of RTOG protocol 90–0510.1016/S0360-3016(99)00507-6 ↗
13. Four-dimensional (4D) image reconstruction strategies in dynamic PET: Beyond conventional independent frame reconstruction10.1118/1.3160108 ↗
14. Evaluating the use of optimally respiratory gated 18F-FDG-PET in target volume delineation and its influence on radiation doses to the organs at risk in non-small-cell lung cancer patients10.1097/MNM.0000000000000409 ↗
15. A phase II comparative study of gross tumor volume definition with or without PET/CT fusion in dosimetric planning for non-small-cell lung cancer (NSCLC): Primary analysis of Radiation Therapy Oncology Group (RTOG) 051510.1016/j.ijrobp.2010.09.033 ↗
16. Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours10.1007/s00259-010-1716-6 ↗
17. Validation of a 4D-PET maximum intensity projection for delineation of an internal target volume10.1016/j.ijrobp.2013.02.030 ↗