journal article·2019-04-26Open access

A Novel Overcurrent Suppression Strategy during Reclosing Process of MMC-HVDC

Bin Jiang, Yanfeng Gong

Applied Sciences· Volume 9· Issue 9

Abstract

A modular multilevel converter based high-voltage DC (MMC-HVDC) system has been the most promising topology for HVDC. A reclosing scheme is usually configured because temporary faults often occur on transmission lines especially when overhead lines are used, which often brings about an overcurrent problem. In this paper, a new fault current limiter (FCL) based on reclosing current limiting resistance (RCLR) is proposed to solve the overcurrent problem during the reclosing process. Firstly, a mesh current method (MCM) based short-circuit current calculation method is newly proposed to solve the fault current calculation of a loop MMC-HVDC grid. Then the method to calculate the RCLR is proposed based on the arm current to limit the arm currents to a specified value during the reclosing process. Finally, a three-terminal loop MMC-HVDC test grid is constructed in the widely used electromagnetic transient simulation software PSCAD/EMTDC and the simulations prove the effectiveness of the proposed strategy.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: HVDC Systems and Fault Protection · High-Voltage Power Transmission Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Electronic Engineering, North China Electric Power University, Beijing 102206, China

References (22)

Show source-provided references
1. The key technologies of VSC-MTDC and its application in China10.1016/j.rser.2016.04.067 ↗
2. Jiang, B., Gong, Y., and Li, Y. (2018). Fault Detection and Location of IGBT Short-Circuit Failure in Modular Multilevel Converters. Energies, 11.10.3390/en11061492 ↗
3. Review of modular multilevel converter based multi-terminal hvdc systems for offshore wind power transmission10.1016/j.rser.2016.01.108 ↗
4. Transient Characteristics Under Ground and Short-Circuit Faults in a ±500 kV MMC-Based HVDC System with Hybrid DC Circuit Breakers10.1109/TPWRD.2018.2795800 ↗
5. Modeling, control, and protection of modular multilevel converter-based multi-terminal HVDC systems: A review10.17775/CSEEJPES.2017.00440 ↗
6. Modular multilevel converter dc fault protection10.1109/TPWRD.2017.2715833 ↗
7. Adaptive single-poleauto-reclosing concept with advanced dc fault current control for full-bridge MMC VSC systems10.1109/TPWRD.2017.2706361 ↗
8. Fault Detection and Interruption in an Earthed HVDC Grid Using ROCOV and Hybrid DC Breakers10.1109/TPWRD.2014.2364547 ↗
9. Application study of superconducting fault current limiters in meshed HVDC grids protected by fast protection relays10.1016/j.epsr.2016.09.008 ↗
10. Research on application of superconducting fault current limiter in MMC-MTDC
11. Larruskain, D.M., Iturregi, A., Abarrategui, O., Etxegarai, A., and Zamora, I. (2016, January 22–24). Fault Current limiting in VSC-HVDC systems with MMC converters. Proceedings of the 2016 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), Anacapri, Italy.10.1109/SPEEDAM.2016.7525896 ↗
12. Resistive DC fault current limiter
13. Li, J., Ding, X.B., Liu, S., Chen, Z.H., and Li, Z.H. (2017, January 25–27). DC fault current-limiting and isolating technique for the MMC-based DC system. Proceedings of the 2017 China International Electrical and Energy Conference (CIEEC), Beijing, China.
14. Generalised protection strategy for HB-MMC-MTDC systems with RL-CFL under dc faults10.1049/iet-gtd.2016.1943 ↗
15. Li, X., Liu, W., Song, Q., Rao, H., and Xu, S. (2013, January 10–13). An enhanced MMC topology with DC fault ride-through capability. Proceedings of the 39th Annual Conference of the IEEE Industrial Electronics Society (IECON 2013), Vienna, Austria.10.1109/IECON.2013.6700152 ↗
16. A novel dc fault ride-through scheme for MTDC networks connecting large-scale wind parks10.1109/TSTE.2017.2651025 ↗
17. Ji, S., Wang, S.L., and Liu, T.Q. (2018, January 10–13). A Soft Reclosing Model for Hybrid DC Circuit Breaker in VSC-MTDC System. Proceedings of the 2018 IEEE 4th Southern Power Electronics Conference (SPEC), Singapore.
18. A novel traveling-wave-based directional protection scheme for MTDC grid with inductive DC terminal10.1016/j.epsr.2017.12.010 ↗
19. Operating DC Circuit Breakers with MMC10.1109/TPWRD.2017.2658540 ↗
20. Kontos, E., Rodrigues, S., Pinto, R.T., and Bauer, P. (2014, January 14–18). Optimization of limiting reactors design for DC fault protection of multi-terminal HVDC networks. Proceedings of the Energy Conversion Congress and Exposition (ECCE), Pittsburgh, PA, USA.10.1109/ECCE.2014.6954134 ↗
21. Kontos, E., and Bauer, P. (2016, January 5–8). Reactor design for DC fault ride-through in MMC-based multi-terminal HVDC grids. Proceedings of the Annual Southern Power Electronics Conference (SPEC), Auckland, New Zealand.10.1109/SPEC.2016.7846039 ↗
22. Single-ended differential protection in MTDC networks using optical sensors10.1109/TPWRD.2016.2645231 ↗