On the Synergy between Elemental Carbon and Inorganic Ions in the Determination of the Electrical Conductance Properties of Deposited Aerosols: Implications for Energy Applications
Source abstract
Abstract
The role of the elemental carbon (EC), in synergy with hygroscopic ionic species, was investigated to study the formation of electrical bridging phenomena once the aerosol deliquescence is achieved. Ambient aerosol samples were collected on hydrophobic surfaces in urban and rural sites in Northern Italy; their conductance was measured in an Aerosol Exposure Chamber (AEC) while varying the relative humidity. An electric signal was detected on 64% of the collected samples with conductance values (11.20 ± 7.43 μS) above the failure threshold (1 μS) of printed circuit boards. The ionic content was higher for non-electrically conductive samples (43.7 ± 5.6%) than for electrically conductive ones (37.1 ± 5.6%). Conversely, EC was two times higher for electrically conductive samples (26.4 ± 4.1 μg cm−2; 8.4 ± 1.7%) than for non-electrical ones (12.0 ± 4.1 μg cm−2; 5.2 ± 1.9%) suggesting that the synergy between the ionic and carbonaceous fractions is necessary to promote a bridging phenomenon. Synthetic aerosols (EC only, saline only, mixed saline and EC) were generated in laboratory and their conductance was measured in the AEC to verify the ambient results. Only in case of a contemporary presence of both EC and ionic components the bridging phenomenon occurred in keeping with the theoretical deliquescence values of each salt (R2 = 0.996).
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Aerosol Filtration and Electrostatic Precipitation · Lightning and Electromagnetic Phenomena · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
GEMMA and POLARIS research centres, University of Milano-Bicocca, Piazza della Scienza 1, 20126 Milano, Italy
RSE Spa, via Rubattino 54, 20134 Milano, Italy
Agenzia Regionale Protezione Ambiente (ARPA) Lombardia, Department of Air Quality, Via Rosellini 17, 20124 Milano, Italy
References (100+)
Show source-provided references
1. Mechanism of Atmospheric Corrosion of Copper in the Presence of Submicron Ammonium Sulfate Particles at 300 and 373 K10.1149/1.2059261 ↗
2. Atmospheric Corrosion
3. Chen, Z.Y. (2005). The Role of Particles on Initial Atmospheric Corrosion of Copper and Zinc. [Ph.D. Thesis, Royal Institute of Technology].
4. A microscopic study of the effects of particle size and composition of atmospheric aerosols on the corrosion of mild steel10.1016/j.corsci.2008.07.009 ↗
5. On the Effects of Atmospheric Particles Contamination and Humidity on Tin Corrosion10.1109/TDMR.2017.2771505 ↗
6. Impact of black carbon aerosol over Italian basin valleys: High-resolution measurements along vertical profiles, radiative forcing and heating rate10.5194/acp-14-9641-2014 ↗
7. Satellite AOD conversion into ground PM10, PM2.5 and PM1 over the Po valley (Milan, Italy) exploiting information on aerosol vertical profiles, chemistry, hygroscopicity and meteorology10.1016/j.apr.2019.08.003 ↗
8. Seasonal behavior of PM2.5 deliquescence, crystallization and hygroscopic growth in the Po Valley (Milan): Implications for remote sensing applications
9. Hygroscopic properties of atmospheric aerosol particles over the Eastern Mediterranean: Implications for regional direct radiative forcing under clean and polluted conditions10.5194/acp-11-4251-2011 ↗
10. Sensitivity of sulfate direct climate forcing to the hysteresis of particle phase transitions
11. Seinfeld, J.H., and Pandis, S.N. (2006). Atmospheric Chemistry and Physics: From Air Pollution to Climate Change, John Wiley and Sons. [2nd ed.].
12. Heterogeneous and Multiphase Chemistry in the Troposphere10.1126/science.276.5315.1058 ↗
13. Relative humidity impact on aerosol parameters in a Paris suburban area
14. Phase Transitions of Aqueous Atmospheric Particles10.1021/cr990034t ↗
15. Crystallization of atmospheric sulfatenitrate-ammonium particles10.1029/2003GL017930 ↗
16. Seinfeld, J.H., and Pandis, S.N. (1998). Atmospheric Chemistry and Physics, John Wiley and Sons.
17. Identifying solid-aqueous-phase transitions in atmospheric aerosols. II. Acidic solutions10.1016/1352-2310(95)00212-H ↗
18. Determination of aerosol deliquescence and crystallization relative humidity for energy saving in free-cooled data centers10.1007/s13762-014-0680-2 ↗
19. Experimental Measurements of Particulate Matter Deliquescence and Crystallization Relative Humidity: Application in Heritage Climatology10.4209/aaqr.2014.11.0289 ↗
20. Aerosol Corrosion Prevention and Energy-Saving Strategies in the Design of Green Data Centers10.1021/es304790f ↗
21. Tschudi, W., Xu, T., Sartor, D., Nordman, B., Koomey, J., and Sezgen, O. (2020, August 10). Energy Efficient Data Centers, Available online: http://www.osti.gov/bridge/servlets/purl/841561-aO7Lg9/native/841561.pdf.
22. Surface flashover of insulators10.1109/14.42158 ↗
23. International Electrotechnical Commission (2008). Selection and Dimensioning of High-Voltage Insulators Intended for Use in Polluted Conditions—Part 1: Definitions, Information and General Principles, International Electrotechnical Commission. IEC/TS 60815-1.
24. Experimental Investigation on Outdoor Insulation for DC Transmission Line at High Altitudes10.1109/TPWRD.2009.2034889 ↗
25. Mechanism of saline deposition and surface flashover on outdoor insulators near coastal areas part II: Impact of various environment stresses10.1109/TDEI.2017.006386 ↗
26. Bojovschi, A., Quoc, T.V., Trung, H.N., Quang, D.T., and Le, T.C. (2019). Environmental Effects on HV Dielectric Materials and Related Sensing Technologies. Appl. Sci., 9.10.3390/app9050856 ↗
27. ENEL (1998). Ricerca—Area Distribuzione Sistemi di Utenza, Corso Coordinamento Dell’Isolamento, Protezione Elettrica e Aspetti Manutentivi delle Reti di Distribuzione MT, ENEL. (In Italian).
28. Lloyd, K.J., and Schneider, H.M. (1982). Insulation for Power Frequency Voltage. Transmission Line Reference Book (345 kV and above), Electric Power Research Institute.
29. Looms, T.J. (1988). Insulators for High Voltage, Peter Peregrinus Ltd.10.1049/PBPO007E ↗
30. Karady, G., and Amarh, F. (1999, January 11–16). Signature analysis for leakage current waveforms of polluted insulators. Proceedings of the IEEE Transmission and Distribution Conference, New Orleans, LA, USA.10.1109/TDC.1999.756152 ↗
31. Indoor particle dynamics10.1111/j.1600-0668.2004.00286.x ↗
32. Are indoor air pollutants threatening the reliability of your electronic equipment?
33. Particle concentrations in data centers10.1016/j.atmosenv.2008.03.049 ↗
34. Shehabi, A. (2009). Energy Demands and Efficiency Strategies in Data Center Buildings, Lawrence Berkeley National Laboratory. Available online: http://escholarship.ucop.edu/uc/item/8xh147cm.10.2172/982905 ↗
35. Effect of Temperature and Relative Humidity on the Impedance Degradation of Dust-Contaminated Electronics10.1149/2.024303jes ↗
36. A multiple stage approach to mitigate the risks of telecommunication equipment under free air cooling conditions10.1016/j.enconman.2012.06.018 ↗
37. Atmospheric corrosion of materials
38. Corrosion of electronics: The role of ionic substances10.1149/1.2095755 ↗
39. Deposition of aerosol (“hygroscopic dust”) on electronics—Mechanism and risk10.1016/j.microrel.2007.10.003 ↗
40. Percolation and cluster distribution. I. Cluster multiple labeling technique and critical concentration algorithm10.1103/PhysRevB.14.3438 ↗
41. Electric Contacts10.1080/00022470.1963.10468199 ↗
42. Corrosion of Electronic Materials and Devices10.1126/science.234.4774.340 ↗
43. Hygroscopic fine mode particle deposition on electronic circuits and resulting degradation of circuit performance: An experimental study10.1034/j.1600-0668.2000.010001047.x ↗
44. Greenberg, S., Mills, E., Tschudi, W., Rumsey, P., and Myatt, B. (2006, January 14–18). Best practices for data centers: Results from benchmarking 22 data centers. Proceedings of the 2006 ACEEE Summer Study on Energy Efficiency in Buildings, Washington, DC, USA. Available online: Http://www.eceee.org/conference_proceedings/ACEEE_buildings/2006/Panel_3/p3_7/paper.
45. Trends in data centre energy consumption under the European Code of Conduct for data centre energy efficiency10.3390/en10101470 ↗
46. On Global Electricity Usage of Communication Technology: Trends to 203010.3390/challe6010117 ↗
47. Koomey, J. (2011). Growth in Data Center Electricity Use 2005 to 2010, Analytics Press.
48. Andrae, A. (2018, January 4). Should we be concerned about the power consumption of ICT?. Proceedings of the Presented at the Around the World Sustainable Research e-Conference, Edmonton, AB, Canada.
49. IPCC (2013). Climate Change 2013: The Physical Science Basis, Cambridge University Press.
50. Heating Rate of Light Absorbing Aerosols: Time-Resolved Measurements, the Role of Clouds, and Source Identification10.1021/acs.est.7b04320 ↗
51. Decomposition of no-clean solder flux systems and their effects on the corrosion reliability of electronics10.1007/s10854-015-3712-x ↗
52. Solder Flux Residues and Humidity-Related Failures in Electronics: Relative Effects of Weak Organic Acids Used in No-Clean Flux Systems10.1007/s11664-014-3609-0 ↗
53. Organics alter hygroscopic behavior of atmospheric particles10.1029/95JD01835 ↗
54. The hygroscopic properties of dicarboxylic and multifunctional acids: Measurements and UNIFAC predictions10.1021/es0107531 ↗
55. Hygroscopic properties of water-soluble matter and humic-like organics in atmospheric fine aerosol
56. Relating hygroscopicity and composition of organic aerosol particulate matter10.5194/acp-11-1155-2011 ↗
57. Physiochemical properties of alkylaminium sulfates: Hygroscopicity, thermostability, and density10.1021/es3004377 ↗
58. The deliquescence behaviour, solubilities, and densities of aqueous solutions of five methyl- and ethyl-aminium sulphate salts10.1016/j.atmosenv.2013.02.036 ↗
59. Polymer Encapsulants for Microelectronics: Mechanisms for Protection and Failure10.1109/33.2979 ↗
60. Light Absorption by Carbonaceous Particles: An Investigative Review10.1080/02786820500421521 ↗
61. Black carbon or brown carbon? The nature of light absorbing carbonaceous aerosols
62. Li, X., Dallmann, T.R., May, A.A., and Presto, A.A. (2020). Seasonal and Long-Term Trend of on-Road Gasoline and Diesel Vehicle Emission Factors Measured in Traffic Tunnels. Appl. Sci., 10.10.3390/app10072458 ↗
63. Microstructure and Water Adsorbability of Aircraft Combustor Soots and Kerosene Flame Soots: Toward an Aircraft-Generated Soot Laboratory Surrogate10.1021/jp034402f ↗
64. The Structure of Hexane Soot I: Spectroscopic Studies10.1366/0003702854249114 ↗
65. Transport of Po Valley aerosol pollution to the northwestern Alps. Part 1: Phenomenology10.5194/acp-19-3065-2019 ↗
66. Chemically and size-resolved particulate matter dry deposition on stone and surrogate surfaces inside and outside the low emission zone of Milan: Application of a newly developed “Deposition Box”10.1007/s11356-018-1220-2 ↗
67. Sources of high PM2.5 concentrations in Milan, Northern Italy: Molecular marker data and CMB modelling10.1016/j.scitotenv.2011.11.026 ↗
68. Can combining economizers with improved filtration save energy and protect equipment in data centers?10.1016/j.buildenv.2009.08.009 ↗
69. An Integrated Approach to Assess Air Pollution Threats to Cultural Heritage in a Semi-confined Environment: The Case Study of Michelozzo’s Courtyard in Florence (Italy)10.1016/j.scitotenv.2009.07.030 ↗
70. Vertically-resolved particle size distribution within and above the mixing layer over the Milan metropolitan area10.5194/acp-10-3915-2010 ↗
71. Wintertime aerosol dynamics and chemical composition across the mixing layer over basin valleys10.1016/j.atmosenv.2012.03.071 ↗
72. Size-resolved aerosol chemical composition over the Italian Peninsula during typical summer and winter conditions10.1016/j.atmosenv.2010.08.008 ↗
73. Mixing height determination by tethered balloon-based particle soundings and modeling simulations10.1016/j.atmosres.2011.06.016 ↗
74. Ultrafine particles and PM 2.5 in the air of cities around the world: Are they representative of each other ?10.1016/j.envint.2019.05.021 ↗
75. Vertical distribution of hydrocarbons in the low troposphere below and above the mixing height: Tethered balloon measurements in Milan, Italy10.1016/j.envpol.2011.08.012 ↗
76. Monitoring of particulate matter outdoors10.1016/S0045-6535(02)00270-9 ↗
77. Influence of collecting substrates on the characterization of hygroscopic properties of inorganic aerosol particles10.1021/ac4042075 ↗
78. A discussion of the molecular mechanisms of moisture transport in epoxy resins10.1002/(SICI)1099-0488(20000301)38:5<792::AID-POLB16>3.0.CO;2-H ↗
79. PM10 sampler deposited air particulates: Ascertaining uniformity of sample on filter through rotated exposure to radiation10.1016/j.nima.2006.03.037 ↗
80. D’Angelo, L. (2016). Atmospheric Aerosol Phase Transitions: Measurements and implications. [Ph.D. Thesis, Environmental Sciences, University of Milano-Bicocca]. (In Italian).
81. Seasonal variations in chemical composition and in vitro biological effects of fine PM from Milan10.1016/j.chemosphere.2009.12.071 ↗
82. Winter fine particulate matter from Milan induces morphological and functional alterations in human pulmonary epithelial cells (A549)10.1016/j.toxlet.2009.03.003 ↗
83. Saathoff, H., Blatt, N., Gimmler, M., Linke, C., and Schurath, U. (2004, January 14–16). Thermographic Characterisation of Different Soot Types. Proceedings of the 8th ETH Conference on Combustion Generated Particles, Zurich, Switzerand. Available online: http://www.sootgenerator.com/documents/CP2004_hs.pdf.
84. Chow, J., Watson, J., and Fung, K. (2006). Climate Change—Characterization of Black Carbon and Organic Carbon Air Pollution Emissions and Evaluation of Measurement Methods, California Air Resources Board Research Division.
85. Watson, J., Chow, J., Lowenthal, D., and Motallebi, N. (2007). Measurement of Ultrafine and Fine Particle Black Carbon and its Optical Properties. Nucleation and Atmospheric Aerosols, Springer.
86. Characterization of a new miniCAST with diffusion flame and premixed flame options: Generation of particles with high EC content in the size range 30 nm to 200 nm10.1080/02786826.2018.1536818 ↗
87. Distribution of n-alkanes in the Northern Italy aerosols: Data handling of gc-ms signals for homologous series characterization10.1021/es1001242 ↗
88. Particle size, chemical composition, seasons of the year and urban, rural or remote site origins as determinants of biological effects of particulate matter on pulmonary cells10.1016/j.envpol.2013.01.012 ↗
89. Characterization of highly porous nanoparticle deposits by permeance measurements10.1016/j.powtec.2010.11.009 ↗
90. Structural Properties and Filter Loading Characteristics of Soot Agglomerates10.1080/02786820903131081 ↗
91. Pressure drop model for nanostructured deposits10.1016/j.seppur.2014.09.032 ↗
92. Baron, P.A., and Willeke, K. (2005). Aerosol Meas. Principles, Techniques and Applications, Wiley-Interscience. [2nd ed.]. IBSN-13: 978-0-471-78492-0.
93. Sandroff, F.S., and Burnett, W.H. (1992, January 18–20). Reliability qualification test for circuit boards exposed to airborne hygroscopic dust. Proceedings of the 42nd Electronic Components & Technology Conference, San Diego, CA, USA.
94. Deliquescence Relative Humidity Measurements Using an Electrical Conductivity Method10.1007/s10953-005-9015-8 ↗
95. Partial crystallization and deliquescence of particles containing ammonium sulfate and dicarboxylic acids
96. Water uptake of internally mixed ammonium sulfate and dicarboxylic acid particles probed by infrared spectroscopy10.1016/j.atmosenv.2013.01.007 ↗
97. Microstructural and loading characteristics of diesel aggregate cakes10.1016/j.powtec.2013.03.028 ↗
98. Computation of electrical conductivity of multicomponent aqueous systems in wide concentration and temperature ranges10.1021/ie9605903 ↗
99. Electrolyte solutions. R. A. Robinson and R. H. Stokes. Academic Press, New York, 195910.1002/app.1960.070030823 ↗
100. Watschke, H., Hilbig, K., and Vietor, T. (2019). Design and Characterization of Electrically Conductive Structures Additively Manufactured by Material Extrusion. Appl. Sci., 9.10.3390/app9040779 ↗