A Fast-Response Calorimeter with Dynamic Corrections for Transient Heat Transfer Measurements
Source abstract
Abstract
Robust fast-response transient calorimeters with novel calorimeter elements have attracted the attention of researchers as new synthetic materials have been developed. This sensor uses diamonds as the calorimeter element, and a platinum film resistance is sputtered on the back to measure the temperature. The surface heat flux is obtained based on the calorimetric principle. The sensor has the advantages of high sensitivity and not being prone to erosion. However, non-ideal conditions, such as heat dissipation from the calorimeter element to the surroundings, can lead to measurement deviation and result in challenges for sensor miniaturization. In this study, a novel transient calorimeter (NTC) with two different sizes was developed using air or epoxy as the back-filling material. Numerical simulations were conducted to explain the complex heat exchange between the calorimeter element and its surroundings, which showed that it deviated from the assumption of an ideal calorimeter sensor. Accordingly, a dynamic correction method was proposed to compensate for the energy loss from the backside of the calorimeter element. The numerical results showed that the dynamic correction method significantly improved the measurement deviation, and the relative error was within 2.3% if the test time was smaller than 12 ms in the simulated cases. Detonation shock tunnel experiments confirmed the results of the dynamic correction method and demonstrated a practical method to obtain the dynamic correction coefficient. The accuracy and feasibility of the dynamic correction method were verified in a single detonation shock tunnel and under shock tube conditions. The NTC calorimeter exhibited good repeatability in all experiments.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Combustion and Detonation Processes · Energetic Materials and Combustion · Thermal and Kinetic Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of High Temperature Gas Dynamics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
Funding
National Natural Science Foundation of China
References (39)
Show source-provided references
1. Comparative study on aerodynamic heating under perfect and nonequilibrium hypersonic flows10.1007/s11433-015-5708-1 ↗
2. Hypersonic aeroheating prediction technique and its trend of development
3. Stagnation point heat flux in hypersonic high enthalpy flows10.1007/BF01414420 ↗
4. High enthalpy flow computation and experiment around the simple bodies
5. Miller, C.G.I. (1982). Comparison of Thin Film Resistance Heat Transfer Gauges with Thin-Skin Transient Calorimeter Gauges in Conventional HW Tunnels.
6. Wannenwetsch, G., Ticatch, L., Kidd, C., and Arterbury, R. (1985, January 19–21). Measurements of wing leading edge heating rates on wind tunnel models using the thin film techniques. Proceedings of the 20th Thermophysics Conference, Williamsburg, VA, USA.10.2514/6.1985-972 ↗
7. Unsteady convective surface heat flux measurements on a cylinder for CFD code validation studies10.1007/s00193-003-0223-0 ↗
8. Convective heat transfer rate distribution over a missile shaped body flying at hypersonic speeds10.1016/j.expthermflusci.2009.02.005 ↗
9. Transient heat flux measurement using a surface junction thermocouple10.1063/1.1484255 ↗
10. A coaxial thermocouple for shock tunnel applications10.1063/1.3494605 ↗
11. Thermal product of type-E fast response temperature sensors
12. Fast response coaxial thermocouple for short duration impulse facilities
13. Design and fabrication of coaxial surface junction thermocouples for transient heat transfer measurements10.1016/j.icheatmasstransfer.2008.03.009 ↗
14. Schultz, D.L., and Jones, T.V. (1973). Heat Transfer Measurements in Short Duration Hypersonic Facilities, North Atlantic Treaty Organization, Advisory Group for Aerospace Research and Development. Technical Report AGARD-AG-165.
15. Development of the calorimeter heat transfer gauge for use in shock tubes10.1063/1.1716258 ↗
16. Theory of transient experimental techniques for surface heat transfer10.1016/0017-9310(96)00015-4 ↗
17. Calorimeter measurement of heat transfer at hypersonic conditions10.2514/3.62082 ↗
18. Nakakita, K., Osafune, T., and Asai, K. (2003, January 6–9). Global heat transfer measurement in a hypersonic shock tunnel using temperature sensitive paint. Proceedings of the 41st AIAA Aerospace Sciences Meeting and Exhibit, Reno, NV, USA. AIAA-2003-0743.10.2514/6.2003-743 ↗
19. Effect of temperature-sensitive-paint thickness on global heat transfer measurement in hypersonic flow
20. Merski, N.R. (1998, January 12–15). Reduction of analysis of phosphor thermography data with the IHEAT software package. Proceedings of the 36th AIAA Aerospace Sciences Meeting and Exhibit, Reno, NV, USA. AIAA-1998-0712.10.2514/6.1998-712 ↗
21. Global aero-heating wind tunnel measurements using improved two-color phosphor thermography methods
22. An integral heat flux sensor with high spatial and temporal resolutions10.1007/s11434-014-0464-6 ↗
23. Measurement techniques in high-enthalpy hypersonic facilities10.1016/0894-1777(94)00066-H ↗
24. Assessment of effective thermal product of surface junction thermocouples on millisecond and microsecond time scales10.1016/S0894-1777(01)00093-0 ↗
25. NIST (2020, July 30). ITS-90 Table for Type E Thermocouple Database, Available online: https://srdata.nist.gov/its90/download/type_e.tab.
26. Thin-Film Thermometer Measurements in Partially Ionized Shock-Tube Flows10.1063/1.1705982 ↗
27. Nawaz, A., and Santos, J.A. (2010–1, January 28). Assessing calorimeter evaluation methods in convective and radiative heat flux environment. Proceedings of the 10th AIAA/ASME Joint Thermophysics and Heat Transfer Conference, Chicago, IL, USA. AIAA-2010-4905.10.2514/6.2010-4905 ↗
28. Santos, J., Oishi, T., and Martinez, E. (2009, January 22–25). Null point calorimeter sweeps with comparisons to thermal FEA model predictions. Proceedings of the 41st AIAA Thermophysics Conference, San Antonio, TX, USA. AIAA-2009-3758.10.2514/6.2009-3758 ↗
29. Improvement of high heat flux measurement using a null-point calorimeter10.2514/1.30092 ↗
30. Recent Developments in Heat-Transfer-Rate, Pressure, and Force Measurements for Hot-Shot Tunnels10.1109/TAES.1968.5408959 ↗
31. Mechanism of graphitization and optical degradation of CVD diamond films by rapid heating treatment10.1016/j.diamond.2016.11.010 ↗
32. Geraets, R.T.P., Mcgilvray, M., Doherty, L., Morgan, R.G., and Vella, S. (2017, January 5–9). Development of a Fast-Response Calorimeter Gauge for Hypersonic Ground Testing. Proceedings of the 33rd AIAA Aerodynamic Measurement Technology and Ground Testing Conference, Denver, Colorado, CO, USA.
33. Development of a novel transient calorimeter10.1360/N092017-00245 ↗
34. Hightower, T.M., Olivares, R.A., and Philippidis, D. (2008, January 18–22). Thermal Capacitance (Slug) Calorimeter Theory Including Heat Losses and Other Decaying Processes. Proceedings of the Thermal amp; Fluids Analysis Workshop 2008, San Jose, CA, USA.
35. Hoffmann, K.A., and Chiang, S.T. (2000). Computational Fluid Dynamics, Engineering Education System. [4th ed.].
36. Zhang, S.Z. (2018). Novel Transient Calorimetric Heat Flux Sensor. [Ph.D. Thesis, University of Chinese Academy of Sciences].
37. Zeng, M. (2007). Numerical Rebuilding of Free-Stream Measurement and Analysis of Nonequilibrium Effects in High Enthalpy Tunnel. [Ph.D. Thesis, Graduate School of the Chinese Academy of Sciences].
38. Engineering relations for heat transfer and friction in high-velocity laminar and turbulent boundary-layer flow over surfaces with constant pressure and temperature