Smart Heating and Cooling Heat Pump System by Standing Column Well and Cross-Mixing Balancing Well Heat Exchangers
Source abstract
Abstract
Standing column well (SCW) geothermal heat exchanger permits a bleeding discharge of less than 20% in the event of a maximum load, which is an inappropriate method of using underground water. In this study, the existing operational method of two adjacent SCW geothermal heat exchangers, each with a single well, was modified. This technology aims to improve the coefficient of performance (COP) of the geothermal system by fundamentally preventing underground water discharge and maintaining a constant temperature of the underground heat exchanger. To curb the bleed water discharge, two balancing wells of cross-mixing methods were employed. The result of the cooling and heating operations with the existing SCW heat exchange system and the balancing well cross-combined heat exchange system showed that the measured COP increases by 23% and 12% during the cooling and heating operations, respectively. When operating with a balanced well cross-mixed heat exchange system, the initial temperature of the underground was constant with a small standard deviation of 0.08–0.12 °C.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geothermal Energy Systems and Applications · Drilling and Well Engineering · CO2 Sequestration and Geologic Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical and Shipbuilding Convergence Engineering, Pukyong National University, Busan 48547, Korea
Department of Architecture Engineering, Songwon University, Gwangju 61756, Korea
References (36)
Show source-provided references
1. Geothermal (ground-source) heat pumps: A world overview
2. Lund, J.W. (2001). Geothermal Heat Pumps—An Overview, Geo-Heat Center, Oregon Institute of Technology. Available online: http://geoheat.oit.edu.
3. Thermal performance evaluation of a vertical closed-loop ground heat exchanger according to rock type in Korea10.1016/j.enbuild.2018.10.046 ↗
4. On temperature attenuation in staged open-loop wells10.1016/j.renene.2012.03.007 ↗
5. The thermal response of an infinite line of open loop wells for ground coupled heat pump systems10.1016/j.ijheatmasstransfer.2011.07.027 ↗
6. Thermal performance of a standing column well geothermal heat exchanger system using re-injection of bleeding water10.1016/j.geothermics.2019.05.015 ↗
7. Solute and heat transport in groundwater similarity: Model application of a high capacity open-loop heat pump10.1016/j.geothermics.2013.10.009 ↗
8. You, J., and Lee, C. (2020). Comparative Analysis of Geothermal Energy in Korea Based on Closed Borehole and Single- and Two-Well Standing Column Well Geothermal Heat Exchange Systems. Appl. Sci., 10.10.3390/app10072467 ↗
9. Change of geothermal properties of groundwater by use of open loop geothermal cooling and heating system
10. In-situ response test of various borehole depths and heat injection rates at standing column well geothermal heat exchanger systems10.1016/j.enbuild.2018.05.009 ↗
11. Geothermal energy recovery from underground mines10.1016/j.rser.2010.11.007 ↗
12. Innovative Approach for Heating of Buildings Using Water from a Flooded Coal Mine Through an Open Loop Based Single Shaft GSHP System10.1016/j.egypro.2015.07.162 ↗
13. Szulc-Wrońska, A., and Tomaszewska, B. (2020). Low Enthalpy Geothermal Resources for Local Sustainable Development: A Case Study in Poland. Energies, 13.10.3390/en13195010 ↗
14. Morrone, P., and Algieri, A. (2020). Integrated Geothermal Energy Systems for Small-Scale Combined Heat and Power Production: Energy and Economic Investigation. Appl. Sci., 10.10.3390/app10196639 ↗
15. Gatsios, T., Cigna, F., Tapete, D., Sakkas, V., Pavlou, K., and Parcharidis, I. (2020). Copernicus Sentinel-1 MT-InSAR, GNSS and Seismic Monitoring of Deformation Patterns and Trends at the Methana Volcano, Greece. Appl. Sci., 10.10.3390/app10186445 ↗
16. Parisi, M.L., Douziech, M., Tosti, L., Pérez-López, P., Mendecka, B., Ulgiati, S., Fiaschi, D., Manfrida, G., and Blanc, I. (2020). Definition of LCA Guidelines in the Geothermal Sector to Enhance Result Comparability. Energies, 13.10.3390/en13143534 ↗
17. Matuszewska, D., Kuta, M., and Olczak, P. (2020). Techno-Economic Assessment of Mobilized Thermal Energy Storage System Using Geothermal Source in Polish Conditions. Energies, 13.10.3390/en13133404 ↗
18. Čeryová, D., Bullová, T., Turčeková, N., Adamickova, I., Moravčíková, D., and Bielik, P. (2020). Assessment of the Renewable Energy Sector Performance Using Selected Indicators in European Union Countries. Resources, 9.10.3390/resources9090102 ↗
19. Agemar, T., Weber, J., and Moeck, I.S. (2018). Assessment and Public Reporting of Geothermal Resources in Germany: Review and Outlook. Energies, 11.10.3390/en11020332 ↗
20. Multi-scale modeling of the environmental impact and energy performance of open-loop groundwater heat pumps in urban areas10.1016/j.applthermaleng.2013.11.028 ↗
21. Influence of open and closed loop geothermal cooling and heating systems on hydrogeological properties
22. Open-loop groundwater heat pumps development for large buildings: A case study10.1016/j.geothermics.2008.12.009 ↗
23. Improved Design Method of Open Loop Geothermal System and its Applications10.7849/ksnre.2016.12.12.4.122 ↗
24. Hydraulic feasibility study on the open-loop geothermal system using a pairing technology10.12813/kieae.2017.17.3.119 ↗
25. Study on the Underground Thermal Environment around Wells for a Design Method of Open-Loop Geothermal System
26. A study on the KS (Korea Standard) of SCW type ground heat exchanger - ground source heat pump system
27. An Experimental Study on the Thermal Performance Evaluation of SCW Ground Heat Exchanger10.1142/S2010132517500067 ↗
28. Ministry of Trade, Industry and Energy (2015). Standards of Support, Installation and Management for New and Renewable Energy System.
29. Sanner, B., Hellström, G., Spitler, J., and Gehlin, S. (2013, January 3–7). More than 15 years of Mobile Thermal Response Test—A Summary of Experiences and Prospects. Proceedings of the European Geothermal Congress, Pisa, Italy.
30. Reference data sets for vertical borehole ground heat exchanger models and thermal response test analysis10.1016/j.geothermics.2010.12.007 ↗
31. A Study on the Heat Transfer Characteristics of Various Construction of SCW Type Ground Heat Exchanger
32. Multi-injection rate thermal response test in groundwater filled borehole heat exchanger10.1016/j.renene.2009.09.012 ↗
33. Borehole temperature evolution during thermal response tests10.1016/j.geothermics.2010.12.002 ↗
34. Analysis and thermal response test for vertical ground heat exchanger with two U-loop configuration
35. Incropera, F.P., and Dewitt, D.P. (1996). Fundamentals of Heat and Mass Transfer, John Wiley and Sons. [4th ed.].
36. Chang, J.H., Park, D.H., Park, S.S., and Na, S.M. (, 2010). Evaluation of Application of Effective Hydraulic Conductivity in SCW Ground Heat Pump System. Proceedings of the Korean Geo-Environmental Society, Fall Conference, Seoul, Korea.