journal article·2020-12-04Open access

Impact of the Enamel Cleaning Procedure during Debonding on Endodontium Temperature: In Vitro Tests

Monika Machoy, Liliana Szyszka-Sommerfeld, Piotr Duda, Anna Wawrzyk, Krzysztof Woźniak, Sławomir Wilczyński

Applied Sciences· Volume 10· Issue 23

Abstract

Interference with live tooth tissue during dental treatment affects the temperature within the pulp. The pulp is sensitive to temperature changes, which can cause its inflammation. The aim of this study was to analyze the dynamics of pulp chamber temperature changes in response to the enamel cleaning procedure after orthodontic treatment. In the presented in vitro studies, by using a thermal imaging camera, the change in the temperature of the vestibular wall of the pulp chamber of the incisors and premolars was assessed as a function of time under the influence of polishing the enamel with the silicone rubber and aluminum oxides used during the debonding procedure after completion of orthodontic treatment with fixed appliances. The relationship between dentin density and enamel from changing the chamber temperature was evaluated by using Micro computed tomography, microtomography (micro-CT). The maximum achieved tooth surface temperature during polishing was 52.34 °C without water cooling and 43.15 °C using water cooling. The time after which a safe pulp temperature of 40 °C was obtained without water cooling was 29.4 s, while the time with water cooling was 34.6 s. The correlation between the maximum and average temperature achieved and the density of the teeth was analyzed based on micro-CT scans. No correlation between enamel or dentin density and rise in temperature was found.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Division of Orthodontics, Pomeranian Medical University in Szczecin, Powstańców Wielkopolskich Street 72, 70-111 Szczecin, Poland

Institute of Biomedical Engineering, Faculty of Science and Technology, University of Silesia in Katowice, Będzińska Street 39, 41-200 Sosnowiec, Poland

Sanitary-Epidemiological Station, Prądnicka 76, 31-202 Kraków, Poland

Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Bedzinska Street 39, 41-200 Sosnowiec, Poland

Funding

Śląski Uniwersytet Medyczny

References (31)

Show source-provided references
1. Zabel, M. (2000). Histologia: Podręcznik dla Studentów Medycyny i Stomatologii, Elsevier Urban & Partner. (In Polish).
2. Effect of composite temperature on in vitro intrapulpal temperature rise10.1016/j.dental.2006.11.024 ↗
3. Parameters influencing increase in pulp chamber temperature with light-curing devices: Curing lights and pulpal flow rates10.2341/09-234-L ↗
4. Pulp response to externally applied heat10.1016/0030-4220(65)90015-0 ↗
5. Pulp-dentin biology in restorative dentistry. Part 6: Reactions to restorative materials, tooth-restoration interfaces, and adhesive techniques
6. Rise in pulp temperature during finishing and polishing of resin composite restorations: An in vitro study
7. Pulpal temperature increases with Er: YAG laser and high-speed handpieces10.1016/j.prosdent.2003.08.022 ↗
8. Effect of simulated pulpal microcirculation on intra chamber temperature changes following application of various curing units on tooth surface10.1016/j.jdent.2009.03.006 ↗
9. Pulpal-temperature rise and polymerization efficiency of LED curing lights10.2341/09-203-L ↗
10. Increases in intra pulpal temperature during polymerization of composite resin10.1016/j.prosdent.2006.09.008 ↗
11. A study of temperature rise in the pulp chamber duringcomposite polymerization with different light-curing units10.5005/jcdp-8-7-29 ↗
12. Comparison of temperature changes in the pulp chamber induced by various light curing units, in vitro10.2341/05-26 ↗
13. Temperature rise on dentin caused by temporary crown and fixed partial denture materials: Influencing factors10.1016/j.jdent.2010.08.008 ↗
14. An investigation of thermal stimulation in intact teeth10.1016/j.archoralbio.2006.10.009 ↗
15. Thermal analysis of the intact mandibular premolar: A finite element analysis10.1111/iej.12069 ↗
16. Anisotropic, gradient and metal-like mechanical behaviors of teeth and their implications on tooth functions10.1007/s11434-007-0368-9 ↗
17. The dentin-enamel junction-a natural, multilevel interface10.1016/S0955-2219(03)00301-7 ↗
18. Niu, L., Dong, S.J., Kong, T.T., Wang, R., Zou, R., and Liu, Q.D. (2016). Heat Transfer Behavior across the Dentino-Enamel Junction in the Human Tooth. PLoS ONE, 11.10.1371/journal.pone.0158233 ↗
19. Enamel shear bond strength of different primers combined with an orthodontic adhesive paste10.1515/bmt-2016-0241 ↗
20. Szyszka-Sommerfeld, L., Matthews-Brzozowska, T., Kawala, B., Mikulewicz, M., Machoy, M., Wiȩckiewicz, W., and Woźniak, K. (2018). Electromyographic analysis of masticatory muscles in cleft lip and palate children with pain-related temporomandibular disorders. Pain Res. Manag., 4182843.10.1155/2018/4182843 ↗
21. The electrical activity of the masticatory muscles in cleft lip and palate children10.1111/ipd.12349 ↗
22. Automatic method of analysis of OCT images in the assessment of the tooth enamel surface after orthodontic treatment with fixed braces10.1186/1475-925X-13-48 ↗
23. Optical coherence tomography as a non-invasive method of enamel thickness diagnosis after orthodontic treatment by 3 different types of brackets10.17219/acem/79974 ↗
24. Evaluation of changes in enamel thickness after orthodontic treatment depending on the force applied to remove orthodontic brackets: OCT analysis and universal testing machine10.17219/acem/94141 ↗
25. Enamel Thickness before and after Orthodontic Treatment Analysed in Optical Coherence Tomography10.1155/2017/8390575 ↗
26. Press-on force during polishing of resin composite restorations10.1016/j.dental.2019.03.009 ↗
27. Evaluation of the influence of the types of orthodontic materials on the enamel surface clean-up after fixed appliances removal
28. Surface roughness and gloss of dental materials as a function of force and polishing time in vitro10.1016/j.dental.2005.04.013 ↗
29. The use of dynamic thermal analysis to distinguish between genuine and counterfeit drugs10.1016/j.ijpharm.2015.04.077 ↗
30. Thermographic mapping of the skin surface in biometric evaluation of cellulite treatment effectiveness10.1111/srt.12301 ↗
31. Tooth mineral density of different types of hypomineralised molars: A micro-CT analysis10.1007/s40368-017-0306-8 ↗