Peri-Implant Bone Damage Procured by Piezoelectric and Conventional Implant Site Preparation: An In Vitro Comparison
Source abstract
Abstract
Background: The conventional drill technique is the most commonly used for the implant site preparation of the desired diameter and length. Ultrasonic implant site preparation (UISP) can also be used to perform an implant site preparation of the desired dimensions. Methods: Implant sites were prepared in fresh bone ribs with two different implant site preparation techniques: implant surgical drills and piezoelectric tips. Samples were analyzed with scanning electron microscopy (SEM) for evaluating the peri-implant bone damage. Result: In the surgical drills group, the cortical bone surface showed several cracks and the bone vascular canals were hidden by a dense smear layer. Cancellous bone showed large irregularities and trabecular fractures. The piezoelectric group showed a clean and smooth cortical bone surface with opened bone vascular canals; the cancellous bone presented a regular morphology, and the trabecular spaces, clearly visible, were free of debris. Conclusions: Ultrasonic implant site preparation showed cleaner bone surfaces and lower bone trauma compared with the preparation using implant surgical drills.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental Radiography and Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Private Practice in Genova, 16121 Genova, Italy
School of Dentistry, University of Genova, 16121 Genova, Italy
Department of Civil, Environmental and Chemical Engineering, University of Genova, 16121 Genova, Italy
Department Neurosciences, Riproductive and Odontostomatological Sciences, University of Naples Federico II, 80138 Napoli, Italy
References (48)
Show source-provided references
1. Marenzi, G., Impero, F., Scherillo, F., Sammartino, J.C., Squillace, A., and Spagnuolo, G. (2019). Effect of different surface treatments on titanium dental implant micro-morphology. Materials, 12.10.3390/ma12050733 ↗
2. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
3. A histometric comparison of smooth and rough titanium implants in human low-density jawbone
4. Lamazza, L., Lollobrigida, M., Vozza, I., Palmieri, L., Stacchi, C., Lombardi, T., and De Biase, A. (2020). Piezoelectric implant site preparation: Influence of handpiece movements on temperature elevation. Materials, 13.10.3390/ma13184072 ↗
5. Microcomputed tomographic analysis of bone reaction at insertion of orthodontic mini-implants in sheep
6. Piezoelectric surgery versus conventional drilling for implant site preparation: A meta-analysis10.1016/j.jpor.2018.04.004 ↗
7. Bernabeu-Mira, J.C., Pellicer-Chover, H., Peñarrocha-Diago, M., and Peñarrocha-Oltra, D. (2020). In vitro study on bone heating during drilling of the implant site: Material, design and wear of the surgical drill. Materials, 13.10.3390/ma13081921 ↗
8. Observational study on the preparation of the implant site with piezosurgery vs. drill: Comparison between the two methods in terms of postoperative pain, surgical times, and operational advantages10.1155/2019/8483658 ↗
9. Marenzi, G., Sammartino, J.C., Scherillo, F., Rengo, C., De Rosa, A., Graziano, V., and Spagnuolo, G. (2019). Comparative analysis of the chemical composition and microstructure conformation between different dental implant bone drills. Materials, 12.10.3390/ma12111866 ↗
10. Does the instrument used for the implant site preparation influence the bone-implant interface? A systematic review of clinical and animal studies10.1016/j.ijom.2018.04.005 ↗
11. Cytokine, chemokine, and growth factor levels in peri-implant sulcus during wound healing and osseointegration after piezosurgical versus conventional implant site preparation: Randomized, controlled, split-mouth trial10.1002/JPER.18-0216 ↗
12. Material attrition and bone micromorphology after conventional and ultrasonic implant site preparation10.1111/j.1600-0501.2011.02389.x ↗
13. Heat production during different ultrasonic and conventional osteotomy preparations for dental implants10.1111/j.1600-0501.2010.02126.x ↗
14. Piezoelectric surgery in implantology: A case report-a new piezoelectric ridge expansion technique
15. Piezosurgery applied to implant dentistry: Clinical and biological aspects10.1563/AAID-JOI-D-11-00196 ↗
16. Piezoelectric vs. conventional drilling in implant site preparation: Pilot controlled randomized clinical trial with crossover design10.1111/clr.12278 ↗
17. Comparative study on the cutting effectiveness and heat generation of rotary instruments versus piezoelectric surgery tips using scanning electron microscopy and thermal analysis10.11607/jomi.5806 ↗
18. Effect of 50 to 60 C heating on osseointegration of dental implants in dense bone: An in vivo histological study10.1097/ID.0000000000000162 ↗
19. Bone heat generated using conventional implant drills versus piezosurgery unit during apical cortical plate perforation10.1002/JPER.17-0502 ↗
20. Temperatures measured in human cortical bone when drilling10.2106/00004623-197254020-00008 ↗
21. Effect of temperature on the dental implant osseointegration development in low-density bone: An in vivo histological evaluation10.1097/ID.0000000000000204 ↗
22. An in vitro evaluation of heat production during osteotomy preparation for dental implants with compressive osteotomes10.1097/ID.0b013e318285984c ↗
23. Ultrasonic versus drills implant site preparation: A histologic analysis in bovine ribs10.1097/SCS.0000000000000713 ↗
24. Clinical influence of micromorphological structure of dental implant bone drills10.1155/2018/8143962 ↗
25. Experimental analysis of temperature differences during implant site preparation: Continuous drilling technique versus intermittent drilling technique10.1563/aaid-joi-D-17-00077 ↗
26. Effects of bur wear during implant site preparation: An in vitro study10.1177/039463200702001s06 ↗
27. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: Twisted stainless steel and ceramic drills10.1111/j.1600-0501.2011.02248.x ↗
28. Heat production by 3 implant drill systems after repeated drilling and sterilization10.1016/j.joms.2005.10.011 ↗
29. Implant site preparation using ultrasonic technique vs. Conventional drilling: Three-year follow-up of a split-mouth study
30. Effect of the laser beam on implant site preparation: A preliminary pilot study
31. Influence of implant bed preparation using an Er:YAG laser on the osseointegration of titanium implants: A histomorphometrical study in dogs10.1111/j.1365-2842.2006.01704.x ↗
32. Pre-operative evaluation of bone quality/density evaluation using novel CT/microCT-based Hard-Normal-Soft classification system
33. The role of bone debris in early healing adjacent to hydrophilic and hydrophobic implant surfaces in man10.1111/j.1600-0501.2010.02107.x ↗
34. Findings of a four-year randomized controlled clinical trial comparing two-piece and one-piece zirconia abutments supporting single prosthetic restorations in maxillary anterior region10.1155/2016/8767845 ↗
35. Coyac, B.R., Salvi, G., Leahy, B., Li, Z., Salmon, B., Hoffmann, W., and Helms, J.A. (2020). A novel system exploits bone debris for implant osseointegration. J. Periodontol.10.1002/JPER.20-0099 ↗
36. Osteotomy speed, heat development, and bone structure influence by various piezoelectric systems-an in vitro study10.1007/s00784-019-02838-8 ↗
37. Temperature values variability in piezoelectric implant site preparation: Differences between cortical and corticocancellous bovine bone10.1155/2016/6473680 ↗
38. Ultrasonic implant site preparation using piezosurgery: A multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up10.11607/prd.1860 ↗
39. Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: A pilot study in minipigs10.1902/jop.2007.060285 ↗
40. Influence of piezosurgery on bone healing around titanium implants: A histological study in rats10.1590/0103-6440201600161 ↗
41. Implant stability in different techniques of surgical sites preparation: An in vitro study
42. Does the drilling technique for implant site preparation enhance implant success in low-density bone? A systematic review10.1097/ID.0000000000000917 ↗
43. Marzook, H.A.M., Yousef, E.A., Denewar, M., and Farahat, M.R.L. (2020). In-vitro assessment of bone viability with different implant drill speeds. Br. J. Oral Maxillofac. Surg.10.1016/j.bjoms.2020.08.013 ↗
44. In vitro evaluation of the primary stability of short implants in different surgical techniques10.11607/jomi.8081 ↗
45. Effects of condensation and compressive strain on implant primary stability: A longitudinal, in vivo, multiscale study in mice10.1302/2046-3758.92.BJR-2019-0161 ↗
46. The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study
47. Osteotome versus conventional drilling technique for implant site preparation: A comparative study in the rabbit
48. Effects on primary stability of three different techniques for implant site preparation in synthetic bone models of different densities10.1016/j.bjoms.2016.07.004 ↗