journal article·2020-12-08Open access

Component Combination Rules of Wind Load Effects of Building Structures

Haiwei Guan, Yuji Tian

Applied Sciences· Volume 10· Issue 24

Abstract

Under the action of the same wind azimuth, the extreme values of the wind load effect components of building structures are generated in the along-wind, cross-wind, vertical, and torsional directions. In designing the wind-resistant structure, the extreme values of effect components need to be combined to determine the internal force envelope values of members. Complete quadratic combination (CQC) and Turkstra combination rules are often used to determine the combination value of extreme values of wind effect components. The extreme probability distribution expressions of the CQC, and the Turkstra and approximate rules, are derived. The simplified combination Equations and combination coefficients of the CQC and Turkstra approximate rules are proposed in this paper. We use the combination Equations and Monte Carlo simulation method to analyze the accuracy of Turkstra and its approximate rules. The results show that the combination extreme is associated with the correlation coefficients, mean values, ratios of standard deviations, and fluctuating extremes of effect components. The errors between Turkstra and its approximate rules are small when load effect components show a positive correlation. The errors are largest when the standard deviations of components are equal. Our research results provide a theoretical basis for the combination method of wind load effect components of building structures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Wind and Air Flow Studies · Probabilistic and Robust Engineering Design

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China

Beijing’s Key Laboratory of Structural Wind Engineering and Urban Wind Environment, Beijing 100044, China

Funding

National Natural Science Foundation of China

References (27)

Show source-provided references
1. Main Contents of the standard for wind loads on roof structures
2. Wind load combination method for high-rise buildings based on extreme-value correlation
3. Combination Method of Wind Load about High rise Buildings Based on Probability Analysis
4. Revisiting combination rules for estimating extremes of linearly combined correlated wind load effects10.1016/j.jweia.2015.02.002 ↗
5. Standards Australia, and Standards New Zealand (2011). Structural Design Actions: Part 2: Wind Actions: AS/NZS 1170.2, 2011, Standards New Zealand.
6. Wind load combinations and extreme pressure distributions on low-rise buildings10.12989/was.2000.3.4.279 ↗
7. Extreme wind- pressure distributions on low-rise building models10.1016/S0167-6105(01)00153-2 ↗
8. Quasi-static wind load combinations for low-and middle-rise buildings10.1016/j.jweia.2003.09.020 ↗
9. Peak normal stresses and effects of wind direction on wind load combinations for medium-rise buildings10.1016/j.jweia.2007.06.027 ↗
10. Correlation and combination of wind force components and responses10.1016/j.jweia.2013.11.015 ↗
11. Tamura, Y. (2006, January 1). Wind Resistant Design of tall buildings in Japan. Proceedings of the 7th National Wind Engineering and Aerodynamics Academic Conference on, Chengdu, Sichuan, China.
12. Efficacy of Turkstra’s combination rule for extremes of nonlinearly combined correlated wind load effects10.1016/j.jweia.2017.08.017 ↗
13. Ministry of Housing and Urban-Rural Development, PRC (2012). Load Code for the Design of Building Structures: GB 50009-2012, China Architecture & Building Press. (In Chinese).
14. Architectural Institution of Japan (AIJ) (2004). Recommendations for Loads on Buildings, Architectural Institute of Japan.
15. Tamura, Y., Kawai, H., Uematsu, Y., Okada, H., and Ohkuma, T. (2004, January 19–20). Documents for wind resistant design of buildings in Japan. Proceedings of the Apecww—Workshop on Regional Harmonization of Wind Loading and Wind Environmental Specifications in Asia-Pacific Economies, Atsugi, Japan.
16. Extension of Turkstra’s rule and their application to combination of dependent load effects10.1016/S0167-4730(00)00004-7 ↗
17. Extreme value statistics of combined load effect processes10.1016/j.strusafe.2008.09.004 ↗
18. Estimation of extreme values from sampled time series10.1016/j.strusafe.2008.06.021 ↗
19. Evaluation of peak resultant response for wind-excited tall buildings10.1016/j.engstruct.2008.11.021 ↗
20. Estimating extremes of combined two Gaussian and non-Gaussian response processes10.1142/S0219455413500764 ↗
21. Gust buffeting and aeroelastic behaviour of poles and monotubular towers10.1006/jfls.1999.0240 ↗
22. Asami, Y. (, 2000). Combination method for wind loads on high-rise buildings. Proceedings of the 16th National Symposium on Wind Engineering, Japan Association for Wind Engineering (JAWE), Tokyo, Japan. (In Japanese).
23. (2010). Eurocode 1: Actions on Structures—Part 1–4: General Actions—Wind Actions: EN 1991-1-4 (2005), European Committee for Standardization. (In English).
24. Ou, J., and Wang, G. (1998). Random Vibration of Structures, Higher Education Press. (In Chinese).
25. Comparison of probability distribution models of non-Gaussian peak factor of wind pressure on cladding and components
26. (2010). Eurocode—Basis of Structural Design: EN 1990 (2002), European Committee for Standardization. (In English).
27. (2020, November 10). NIST Aerodynamic Database, Available online: https://www.nist.gov/el/materials-and-structural-systems-division-73100/nist-aerodynamic-database.