journal article·2021-01-25Open access

Magnetic Resonance Imaging for Assessment of Endodontic Instruments’ Precision during “L-Shaped” Model Root Canals Preparation

Tomasz Olek, Władysław P. Węglarz, Agata Trzcionka, Arkadiusz Dziedzic, Marta Tanasiewicz

Applied Sciences· Volume 11· Issue 3

Abstract

The purpose of the mechanical root canal preparation is to clean it and give it the right shape. The preparation should be carried out in a way that maintains the original curvature and initial orientation of the apical end. Insufficient root canal preparation may prevent effective chemical decontamination and obturation to the full working length. The study aims to evaluate the shaping ability and effectiveness of the NiTi rotary and reciprocating endodontic instruments, compared to standard hand files using magnetic resonance imaging based on spin echo. Material and methods: A comparative study of severely curved root canals’ shaping abilities using three NiTi systems and K-type hand files was performed, with 40 training “endo-blocks” presenting with “L-shaped” canal. The root canal topography and geometry “before” and “after” mechanical preparation obtained by the magnetic resonance imaging based on the spin echo was used. The main measurement was made using the RARE sequence, with slice thickness reduced to 100 micrometers. In order to improve the signal-to-noise ratio, NA = 25 was used. To minimize the measurement time, the field of view was limited to a cuboid 17 × 16 × 3 mm, with a resolution of 33 × 31 × 100 micrometers. Each 3D image consisted of 512 × 512 × 30 voxels. The imaging plane has been selected in such a way as to fully illustrate the course of curvature of the model root canal. For TR = 5 s and effective TE = 36 ms, TA was 1.5 h. Measurements were performed twice, before and after the preparation of endo-blocs with a selected type of endodontic tools. Results: The use of rotary NiTi instruments caused a substantial alteration in the curvature topography and angle of the canals and change in the curvature length. The substantial discrepancy was observed during the preparation of simulated root canals with the reciprocating instruments and the use of WaveOne files led to the largest volume variation. No dependence between the amount of material removed and the measured intracanal side was observed when NiTi instruments were used. Preparation with hand K-type files revealed a relationship between the measuring side and the amount of material removed, with the lower values obtained for the canals’ internal curvatures. Conclusions: All the studied endodontic instruments allow a safe preparation of curved root canals in simulating in vivo conditions. The abbreviation of original root canals topography does not seem to be significantly altered following mechanical preparation of simulated, severely curved root canals. The spin echo-based magnetic resonance imaging technique can be utilized for visualization of the internal topography of the root’s canals in vitro before and after their mechanical preparation in in vitro conditions. In the future, magnetic resonance microscopy may become a diagnostic tool supporting the work of a clinician.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental Radiography and Imaging · Drilling and Well Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Conservative Dentistry with Endodontics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Plac Akademicki 17, 41-902 Bytom, Poland

Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Kraków, Poland

References (38)

Show source-provided references
1. Succesful Endodontic Outcome with Non-Obturated Canals
2. Healing of apical periodontitis after endodontic treatment with and without obturation in dogs10.1016/j.joen.2005.12.014 ↗
3. Shaping ability of progressive versus constant taper instruments in curved root canals of extracted teeth10.1111/j.1365-2591.2007.01296.x ↗
4. In vitro investigation of the cleaning efficacy, shaping ability, preparation time and file deformation of continuous rotary, reciprocating rotary and manual instrumentations in primary molars10.15171/joddd.2016.008 ↗
5. Root canal preparation with the NiTi systems K3, Mtwo and ProTaper10.1111/j.1747-4477.2007.00062.x ↗
6. Comparison of root canal preparation using RaCe and ProTaper rotary NiTi instrumets10.1111/j.1365-2591.2004.00889.x ↗
7. Kształtowanie sztucznych kanałów korzeniowych w kształcie litery L trzema niklowo-tytanowymi systemami narzędzi endodontycznych
8. Porównanie stopnia opracowania sztucznych opracowania sztucznych kanałów w kształcie litery L dwoma systemami maszynowymi
9. Carpegna, G., Alovisi, M., Paolino, D.S., Marchetti, A., Gibello, U., Scotti, N., Pasqualini, D., Scattina, A., Chiandussi, G., and Berutti, E. (2020). Evaluation of Pressure Distribution against Root Canal Walls of NiTi Rotary Instruments by Finite Element Analysis. Appl. Sci., 10.10.3390/app10082981 ↗
10. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation10.1111/j.1365-2591.2005.01010.x ↗
11. Lee, J.K., Lee, S.H., Hong, J.R., Kum, K.Y., Oh, S., Al-Ghamdi, A.S., Al-Ghamdi, F.A., Mandorah, A.O., Jang, A.J., and Chang, S.W. (2020). Three-Dimensional Analysis of Root Anatomy and Root Canal Curvature in Mandibular Incisors Using Micro-Computed Tomography with Novel Software. Appl. Sci., 10.10.3390/app10124385 ↗
12. Solid-state nuclear magnetic resonance microscopy demonstrating human dental anatomy10.1067/moe.2002.126019 ↗
13. Application of Magnetic Resonance Imaging in Dentistry to Caries Lesion Detection and 3D Visualization as an Alternative Non-Invasive Diagnostic Method
14. Mikroobrazowanie metodą magnetycznego rezonansu jądrowego (MRM) w stomatologii
15. MR imaging of teeth using a silent single point imaging technique10.1007/s00339-007-4066-x ↗
16. Fiji: An open-source platform for biological-image analysis10.1038/nmeth.2019 ↗
17. Analiza porównawcza opracowania symulowanych zakrzywionych kanałów korzeniowych typu “S” za pomocą narzędzi rotacyjnych Mtwo i ProTaper oraz narzędzi recyprokalnych Reciproc i WaveOne-badanie in vitro
18. Shaping ability of progressive versus constant taper instruments in simulated root canals10.1111/j.1365-2591.2006.01151.x ↗
19. Shaping ability of two rotary instruments I simulated canals: Stainless steel ENDOflash and nickel-titanium HERO Shaper10.1111/j.1365-2591.2005.00997.x ↗
20. A comparative evaluation on the cleaning and shaping ability of three nickel titanium rotary instruments using computerized tomography—An ex vivo study10.4103/0976-237X.101070 ↗
21. Porównanie efektywności opracowywania zakrzywionych kanałów korzeniowych za pomocą ręcznych narzędzi stalowych i maszynowych narzędzi niklowo-tytanowych-badania na bloczkach żywicowych
22. Shaping ability of rotatory or reciprocating instruments in curved canals: A micro-computed tomographic study10.1590/1807-3107BOR-2016.vol30.0086 ↗
23. Porównanie stopnia opracowania sztucznych kanałów w kształcie litey „L” dwoma systemami maszynowymi: eS5 EndoStar i PrTaper
24. Opracowanie kanałów korzeniowych narzędziami rotacyjnymi RaCe- badania laboratoryjne
25. Properties of mechanical endodontic instruments and the quality of the simulated canal preparation10.17219/dmp/63946 ↗
26. Ocena deformacji naturalnego przebiegu kanału korzeniowego w następstwie preparacji z użyciem ręcznych narzędzi stalowych i systemu rotacyjnych narzędzi niklowo-tytanowych S5
27. A comparison of canal preparations in straight and curved root canals10.1016/0030-4220(71)90230-1 ↗
28. Cyclic fatigue testing of nickel-titanium endodontic instruments10.1016/S0099-2399(97)80250-6 ↗
29. A comparative study of three different root canal curvature measurement techniques and measuring the canal access angle in curved canals10.1097/01.don.0000158232.77240.01 ↗
30. Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth10.1097/00004770-200203000-00017 ↗
31. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper10.1111/j.1365-2591.2011.01996.x ↗
32. Li, K.Z., Gao, Y., Zhang, R., Hu, T., and Guo, B. (2011). The effect of a manual instrumentation technique on five types of premolar root canal geometry assessed by microcomputed tomography and three-dimensional reconstruction. BMC Med. Imaging, 11.10.1186/1471-2342-11-14 ↗
33. Micro-computed tomography evaluation of root canal preparation using rotary system and hand instrument in young permanent molars10.4103/2321-6646.155568 ↗
34. Wei, Z., Cui, Z., Yan, P., and Jiang, H. (2017). A comparison of the shaping ability of three nickel-titanium rotary instruments: A micro-computed tomography study via a contrast radiopaque technique in vitro. BMC Oral Health, 17.10.1186/s12903-016-0326-5 ↗
35. Magnetic resonance imaging in human teeth internal space visualization for requirements of dental prosthetics10.4317/jced.2.e6 ↗
36. Lokalizacja ubytków próchnicowych z wykorzystaniem obrazowania magnetyczno-rezonansowego
37. Magnetic resonance imaging in endodontic treatment prediction10.1016/j.jmir.2010.07.002 ↗
38. 3D MR Microscopy of dental cavities. An in vitro study10.1016/j.ssnmr.2003.03.010 ↗