Nowadays, one of the foremost procedures for strengthening concrete structures is the Near-Surface Mounted (NSM) technique. This paper presents an experimental study on the effect sustained loading and different service temperatures (steady and cyclic) have on NSM Carbon Fibre-Reinforced Polymer (CFRP)-concrete bonded joints and their post-sustained loading load-slip behaviour. Four experimental campaigns using eight NSM CFRP-concrete specimens were performed by employing two different service load levels (15% and 30% of the ultimate load) and combining two groove thicknesses (7.5 and 10 mm) and two bonded lengths (150 and 225 mm). Two steady state temperatures (20 and 40 °C) and two cyclic service temperatures (ranging between 20 and 40 °C) were programmed. The slip obtained was proportional to the sustained load level. Furthermore, higher slips were registered for specimens under higher mean temperatures in the cycle. After 1000 h of sustained load testing, the specimens were tested under monotonic loading until failure (post-sustained loading tests). In general, the ratio between the post-sustained loading ultimate load and the instantaneous ultimate load was close to the unity, although some differences were perceived in series S2 (steady 37.7 °C) with a mean increase of 6.3%, and series S3-B (cyclic temperature ranging between 24.6 and 39.2 °C) with a mean reduction of 9%.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Analysis and Advanced Materials for Structural Design (AMADE), Polytechnic School, University of Girona, 17003 Girona, Spain

Department of Mechanical Engineering, Technical University of Madrid, 28006 Madrid, Spain

Funding

Ministerio de Ciencia, Innovación y Universidades · Universitat de Girona

References (31)

Show source-provided references
1. International Federation for Structural Concrete (2019). Fib Bulletin 90. Externally Applied FRP Reinforcement for Concrete Structures, International Federation for Structural Concrete.
2. ACI Committee 440 (2017). ACI 440.2R-17. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Existing Structures, American Concrete Institute.
3. CNR (2013). Guidelines for the Design and Construction of Externally Bonded FRP Systems for Strengthening Existing Structures—Timber Structures, CNR-DT 200 R1/2013, Advisory Committee on Technical Recommendations for Construction.
4. Temperature and humidity effects on behavior of grouts
5. Krivenko, P. (2020). Compressive behavior of concrete under environmental effects. Compressive Strength of Concrete, IntechOpen.10.5772/intechopen.80174 ↗
6. Investigation of steel fiber effects on concrete abrasion resistance
7. Durability of bond in NSM CFRP-concrete systems under different environmental conditions10.1016/j.compositesb.2017.11.022 ↗
8. Durability of Adhesively Bonded FRP-to-Concrete Joints10.1061/(ASCE)CC.1943-5614.0000657 ↗
9. Sustained Loading and Temperature Response of Fiber-Reinforced Polymer–Concrete Bond10.3141/2131-15 ↗
10. Bond behavior of NSM CFRP laminates in concrete under sustained loading10.1016/j.conbuildmat.2018.05.050 ↗
11. Experimental study and numerical prediction of the bond response of NSM CFRP laminates in RC elements under sustained loading10.1016/j.conbuildmat.2021.123082 ↗
12. Effects of Freeze-Thaw Cycles on the Behavior of the Bond between CFRP Plates and Concrete Substrates10.1061/(ASCE)CC.1943-5614.0000846 ↗
13. Durability of CFRP–concrete joints under freeze–thaw cycling10.1016/j.coldregions.2010.11.008 ↗
14. Influence of Temperature Cycles on Bond between Glass Fiber-Reinforced Polymer and Concrete
15. Bond–slip on CFRP/GFRP-to-concrete joints subjected to moisture, salt fog and temperature cycles10.1016/j.compositesb.2013.06.015 ↗
16. A temperature-dependent bond-slip model for CFRP-to-steel joints10.1016/j.compstruct.2019.03.019 ↗
17. Influence of service temperature and strain rate on the bond performance of CFRP reinforcement in concrete10.1016/j.compstruct.2015.02.076 ↗
18. Effect of elevated service temperature on bond between FRP EBR systems and concrete10.1016/j.compositesb.2008.06.004 ↗
19. Bond behavior of near surface mounted CFRP rods under temperature cycling10.1016/j.engstruct.2017.01.057 ↗
20. Dash, S., Jeong, Y., Lopez, M.M., and Bakis, C.E. (2013, January 26–28). Experimental Characterization of moisture, temperature and sustained loading on concrete-FRP bond performance. Proceedings of the 11th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures—FRPRCS-11, Guimarães, Portugal.
21. Effects of temperature and sustained loading on the mechanical response of CFRP bonded to concrete10.1016/j.conbuildmat.2016.07.123 ↗
22. Integrity of CFRP-concrete bond subjected to long-term cyclic temperature and mechanical stress10.1016/j.compstruct.2016.04.040 ↗
23. Bond characteristics of CFRP-strengthened concrete members subjected to cyclic temperature and mechanical stress at low humidity10.1016/j.compstruct.2016.10.131 ↗
24. Bond behaviour of NSM FRP strips in service10.1680/stco.2007.00015 ↗
25. Bond response of NSM CFRP strips in concrete under sustained loading and different temperature and humidity conditions10.1016/j.compstruct.2018.02.048 ↗
26. Gómez, J., Torres, L., and Barris, C. (2020). Characterization and Simulation of the Bond Response of NSM FRP Reinforcement in Concrete. Materials, 13.10.3390/ma13071770 ↗
27. ASTM International (2010). ASTM C469/C469M-10. Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio of Concrete in Compression, ASTM International.
28. Spanish Association of Normalization (2003). UNE 12390-3. Testing Hardened Concrete. Part 3: Compressive Strength of Test Specimens, AENOR.
29. International Organization for Standardization (2009). ISO 527-5:2009. Determination of Tensile Properties—Part 5: Test Conditions for Unidirectional Fibre-Reinforced Plastic Composites, International Organization for Standardization.
30. ASTM International (1999). ASTM D3418-99: Standard Test Method for Transition Temperatures of Polymers by Differential Scanning Calorimetry, ASTM International.
31. International Organization for Standardization (2012). ISO 527-2:2012. Determination of Tensile Properties—Part 2: Test Conditions for Moulding and Extrusion Plastics, International Organization for Standardization.