journal article·2021-10-22Open access

A New Coupling Method for Accurate Measurement of Pedicle Screw Electrical Properties for Surgical Procedures

Pedro Fonseca, Márcio Fagundes Goethel, Ricardo Sebastião, Manoela Vieira Sousa, João Paulo Vilas-Boas, Miguel Velhote Correia, Manuel Gutierres

Applied Sciences· Volume 11· Issue 21

Abstract

The objective of this study is to present a new coupling method in order to measure the electrical properties of titanium alloy pedicle screws used in spinal surgery and to compare it with other common methods of measurement. An experimental setup was devised to test the electrical resistance of two specimens of pedicle screws using four methods for coupling the sensing leads, including the use of multimeter probes, alligator clips, wrapped wires and encapsulation with thermo-retractable sleeves. The electrical resistance of the pedicle screw under testing was measured at a current of 10 mA for each coupling method, and the results compared. Our findings show that although widely used in electrical analysis, the alligator clips do not perform as well as the other methods, such as simple wrapping of wires around the screw or the direct application of multimeter probes. The use of thermo-retractable sleeves provides the lowest resistance and inter-quartile range and is closer to the tabled values for the screw’s titanium alloy. Additionally, only this method allows the measurement of identical resistivity values between different screw models manufactured with the same titanium alloy. We then concluded that the use of wrapped wires encapsulated with thermo-retractable sleeves allow more accurate measurements of the pedicle screw’s electrical properties.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Intraoperative Neuromonitoring and Anesthetic Effects · Aortic Disease and Treatment Approaches

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Porto Biomechanics Laboratory, University of Porto (LABIOMEP-UP), 4200-450 Porto, Portugal

Faculty of Engineering, University of Porto (FEUP), 4200-465 Porto, Portugal

Faculty of Sport, University of Porto (FADEUP), 4200-450 Porto, Portugal

Centre of Research, Education, Innovation and Intervention in Sport, Faculty of Sport, University of Porto (CIFI2D), 4200-450 Porto, Portugal

Institute for Systems and Computer Engineering, Technology and Science (INESCTEC), 4200-465 Porto, Portugal

Faculty of Medicine, University of Porto (FMUP), 4200-319 Porto, Portugal

References (23)

Show source-provided references
1. Kumar, M., Kofke, W.A., Levine, J.M., and Schuster, J. (2018). Intraoperative Neuromonitoring for Specific Neurosurgical Procedures. Neurocritical Care Management of the Neurosurgical Patient, Elsevier.
2. A Bibliometric analysis of intraoperative neuromonitoring in spine surgery10.1016/j.wneu.2021.07.039 ↗
3. Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Initial clinical results10.1097/00007632-199412150-00008 ↗
4. Accuracy of thoracic pedicle screw placement using freehand technique and triggered EMG in adolescent idiopathic scoliosis: Is it different between concave and convex side?10.1177/2309499018784975 ↗
5. Electromyography stimulation compared with intraoperative O-arm imaging for evaluating pedicle screw breaches in lumbar spine surgery: A prospective analysis of 1006 screws in 164 patients10.1016/j.spinee.2018.06.353 ↗
6. Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws10.1302/0301-620X.83B7.0831009 ↗
7. Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine: Analysis of 2450 consecutively placed screws10.3171/2011.3.SPINE101 ↗
8. Can triggered electromyography thresholds assure accurate pedicle screw placements? A systematic review and meta-analysis of diagnostic test accuracy10.1016/j.clinph.2014.11.026 ↗
9. The use of intraoperative triggered electromyography to detect misplaced pedicle screws: A systematic review and meta-analysis10.3171/2015.6.SPINE141323 ↗
10. Effectiveness of EMG use in pedicle screw placement for thoracic spinal deformities10.1055/s-0031-1298599 ↗
11. Verification of nerve root decompression during minimally-invasive lumbar microdiskectomy: A practical application of surgeon-driven evoked EMG10.1055/s-2005-915594 ↗
12. Solid and hollow pedicle screws affect the electrical resistance: A potential source of error with stimulus-evoked electromyography10.4103/0019-5413.114915 ↗
13. Liu, M.-Y., Tsai, T.-T., Lai, P.-L., Hsieh, M.-K., Chen, L.-H., and Tai, C.-L. (2020). Biomechanical comparison of pedicle screw fixation strength in synthetic bones: Effects of screw shape, core/thread profile and cement augmentation. PLoS ONE, 15.10.1371/journal.pone.0229328 ↗
14. Comparison of the mechanical properties of two designs of polyaxial pedicle screw10.1016/j.engfailanal.2018.08.023 ↗
15. Experimental analysis of pedicle screws10.1016/j.prostr.2016.06.159 ↗
16. Evaluation of the intrinsic properties of pedicle screws: Do diamater, manufacturing and screw design affect resistance and/or resistivity10.17305/bjbms.2009.2767 ↗
17. Can triggered electromyography be used to evaluate pedicle screw placement in hydroxyapatite-coated screws: An electrical examination10.1097/WNP.0000000000000040 ↗
18. Limitations and pitfalls of the pedicle screw testing monitoring technique: An in vivo and in vitro study10.1016/j.neucli.2017.09.003 ↗
19. Pedicle screws with high electrical resistance: A potential source of error with stimulus-evoked EMG10.1097/00007632-200207150-00018 ↗
20. Ksiazkiewicz, A., Dombek, G., and Nowak, K. (2019). Change in electric contact resistance of low-voltage relays affected by fault current. Materials, 12.10.3390/ma12132166 ↗
21. Cooper, H., and Hedges, L.V. (1994). Parametric measures of effect size. The Handbook of Research Synthesis, Russell Sage Foundation.
22. Cohen, J. (1988). Statistical Power Analysis for the Behavioral Sciences, Lawrence Erlbaum Associates. [2nd ed.].
23. ASM International Handbook Committe (1990). Properties and Selection: Nonferrous Alloys and Special-Purpose Materials, ASM International.