journal article·2026-03-11Open access

Loading of the Glenohumeral Joint: Biomechanical Evaluation Tools for Shoulder-Supporting Exoskeletons

Maximilian Ebenbichler, Benjamin Reimeir, David Scherb, Robert Eberle, Robert Weidner

Applied Sciences· Volume 16· Issue 6

Abstract

Due to their potential to reduce occupational physical strain and enhance human performance, the development of exoskeletons has gained significant attention. This study presents a musculoskeletal simulation pipeline designed to evaluate the biomechanical effects of shoulder-supporting exoskeletons. The focus of the investigation is on the biomechanical tools obtained from musculoskeletal simulations for the evaluation of exoskeletons. Such tools result in many biomechanical values, such as joint kinematics, external joint torques, muscle activation and joint reaction forces. The pipeline was applied to a use case, where electromyography (EMG) signals were collected and compared with simulated muscle activations for validation. The simulated muscle activations had a relative root mean square error (RMSE) of 37% in the area under the curve (AUC) compared to the EMG muscle activation. Joint reaction force analysis revealed altered magnitude and direction of the tangential JRF in the glenohumeral joint during exoskeleton support. This work raises the question of whether the focus in the development of shoulder exoskeletons should be on reducing the load on the subacromial space. By analyzing joint reaction forces and muscle activations, the pipeline can help to identify design parameters that reduce the load on the rotator cuff in the subacromial space.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Shoulder Injury and Treatment · Stroke Rehabilitation and Recovery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Mechatronics, University of Innsbruck, 6020 Innsbruck, Austria

Department of Sport Science, University of Innsbruck, 6020 Innsbruck, Austria

Chair for Automated and Autonomous Systems (AAS), TU Bergakademie Freiberg, 09599 Freiberg, Germany

Unit for Engineering Mathematics, Department of Engineering Science, University of Innsbruck, 6020 Innsbruck, Austria

Laboratory of Manufacturing Technology, Helmut Schmidt University, 22043 Hamburg, Germany

Funding

dtec.bw—Digitalization and Technology Research Center of the Bundeswehr

References (55)

Show source-provided references
1. Yao, Z., Mir Latifi, S.M., Molz, C., Scherb, D., Löffelmann, C., Sänger, J., Miehling, J., Wartzack, S., Lindenmann, A., and Matthiesen, S. (2024). A Novel Approach to Simulating Realistic Exoskeleton Behavior in Response to Human Motion. Robotics, 13.10.3390/robotics13020027 ↗
2. Molz, C., Scherb, D., Löffelmann, C., Sänger, J., Yao, Z., Lindenmann, A., Matthiesen, S., Weidner, R., Wartzack, S., and Miehling, J. (2024). A Co-Simulation Model Integrating a Musculoskeletal Human Model with Exoskeleton and Power Tool Model. Appl. Sci., 14.10.3390/app14062573 ↗
3. Flor-Unda, O., Casa, B., Fuentes, M., Solorzano, S., Narvaez-Espinoza, F., and Acosta-Vargas, P. (2023). Exoskeletons: Contribution to Occupational Health and Safety. Bioengineering, 10.10.3390/bioengineering10091039 ↗
4. The Influence of Using Exoskeletons during Occupational Tasks on Acute Physical Stress and Strain Compared to No Exoskeleton—A Systematic Review and Meta-Analysis10.1016/j.apergo.2021.103385 ↗
5. Systematic Review on Wearable Lower-Limb Exoskeletons for Gait Training in Neuromuscular Impairments
6. Modelling for Design and Evaluation of Industrial Exoskeletons: A Systematic Review10.1016/j.apergo.2023.104100 ↗
7. Biomechanical Evaluation of Compliance Joint Knee Exoskeleton During Normal Gait10.5829/IJE.2024.37.10A.20 ↗
8. Sänger, J., Wirth, L., Yao, Z., Scherb, D., Miehling, J., Wartzack, S., Weidner, R., Lindenmann, A., and Matthiesen, S. (2023). ApOL-Application Oriented Workload Model for Digital Human Models for the Development of Human-Machine Systems. Machines, 11.10.3390/machines11090869 ↗
9. Model-Free Based Adaptive BackStepping-Super Twisting-RBF Neural Network Control with α-Variable for 10 DOF Lower Limb Exoskeleton10.1007/s41315-024-00322-5 ↗
10. Reimeir, B., Dangel, L., Drees, T., Ebenbichler, M., Eberle, R., Kuhlenkötter, B., and Weidner, R. (Wearable Technol., 2026). Empirical Computational Models of Support Behavior for Active and Passive Occupational Exoskeletons, Wearable Technol., submitted.
11. OpenSim: A Musculoskeletal Modeling and Simulation Framework for in Silico Investigations and Exchange10.1016/j.piutam.2011.04.021 ↗
12. Risk Factors for Incidence of Rotator Cuff Syndrome in a Large Working Population10.5271/sjweh.3285 ↗
13. Associations between Work-Related Factors and Specific Disorders of the Shoulder—A Systematic Review of the Literature10.5271/sjweh.2895 ↗
14. The Effect of Rotator Cuff Tears on Reaction Forces at the Glenohumeral Joint10.1016/S0736-0266(01)00137-1 ↗
15. The Working Shoulder: Assessing Demands, Identifying Risks, and Promoting Healthy Occupational Performance10.1179/1743288X11Y.0000000032 ↗
16. Effect of an Ankle–Foot Orthosis on Gait Kinematics and Kinetics: Case Study of Post-Stroke Gait Using a Musculoskeletal Model and an Orthosis Model10.1186/s40648-019-0137-y ↗
17. Zhang, F., Chen, J., Wang, W., Han, H., Li, X., and Zhang, J. (2021, January 8–10). Optimization of Gait Assistance Pattern for Charcot-Marie-Tooth Patients Based on Forward Predictive Simulation. Proceedings of the 2021 International Conference on Computer, Control and Robotics (ICCCR), Shanghai, China.10.1109/ICCCR49711.2021.9349388 ↗
18. Akbas, T., and Sulzer, J. (2019, January 24–28). Musculoskeletal Simulation Framework for Impairment-Based Exoskeletal Assistance Post-Stroke. Proceedings of the 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR), Toronto, ON, Canada.10.1109/ICORR.2019.8779564 ↗
19. The Effect of Muscle Weakness on the Capability Gap during Gross Motor Function: A Simulation Study Supporting Design Criteria for Exoskeletons of the Lower Limb10.1186/1475-925X-13-111 ↗
20. Scherb, D., Wartzack, S., and Miehling, J. (2023). Modelling the Interaction between Wearable Assistive Devices and Digital Human Models—A Systematic Review. Front. Bioeng. Biotechnol., 10.10.3389/fbioe.2022.1044275 ↗
21. Musculoskeletal Modelling Deconstructs the Paradoxical Effects of Elastic Ankle Exoskeletons on Plantar-Flexor Mechanics and Energetics during Hopping10.1242/jeb.107656 ↗
22. Wu, Y., Zhu, A., Shen, H., Shen, Z., Zhang, X., and Cao, G. (2019, January 24–27). Biomechanical Simulation Analysis of Human Lower Limbs Assisted by Exoskeleton. Proceedings of the 2019 16th International Conference on Ubiquitous Robots (UR), Jeju, Republic of Korea.10.1109/URAI.2019.8768685 ↗
23. Michaud, F., Mouzo, F., Lugrís, U., and Cuadrado, J. (2019). Energy Expenditure Estimation During Crutch-Orthosis-Assisted Gait of a Spinal-Cord-Injured Subject. Front. Neurorobot., 13.10.3389/fnbot.2019.00055 ↗
24. Assessing the Efficiency of Exoskeletons in Physical Strain Reduction by Biomechanical Simulation with AnyBody Modeling System10.1017/wtc.2021.5 ↗
25. The Exo4Work Shoulder Exoskeleton Effectively Reduces Muscle and Joint Loading during Simulated Occupational Tasks above Shoulder Height10.1016/j.apergo.2022.103800 ↗
26. Bianco, N.A., Franks, P.W., Hicks, J.L., and Delp, S.L. (2022). Coupled Exoskeleton Assistance Simplifies Control and Maintains Metabolic Benefits: A Simulation Study. PLoS ONE, 17.10.1371/journal.pone.0261318 ↗
27. Dembia, C.L., Silder, A., Uchida, T.K., Hicks, J.L., and Delp, S.L. (2017). Simulating Ideal Assistive Devices to Reduce the Metabolic Cost of Walking with Heavy Loads. PLoS ONE, 12.10.1371/journal.pone.0180320 ↗
28. Simulating the Dynamics of a Human-Exoskeleton System Using Kinematic Data with Misalignment Between the Human and Exoskeleton Joints
29. Modeling and Analysis of Physical Human-Robot Interaction of an Upper Body Exoskeleton in Assistive Applications10.4173/mic.2021.4.2 ↗
30. Model-Based Comparison of Passive and Active Assistance Designs in an Occupational Upper Limb Exoskeleton for Overhead Lifting10.1080/24725838.2021.1954565 ↗
31. Tröster, M., Budde, S., Maufroy, C., Andersen, M.S., Rasmussen, J., Schneider, U., and Bauernhansl, T. (2022). Biomechanical Analysis of Stoop and Free-Style Squat Lifting and Lowering with a Generic Back-Support Exoskeleton Model. Int. J. Environ. Res. Public. Health, 19.10.3390/ijerph19159040 ↗
32. Dangel, L., Reimeir, B., and Weidner, R. (2023). ExoPowerCheck: A Performance Test Bench to Measure Support Behavior of Exoskeletons with Single-DoF Support. Proceedings of the Annals of Scientific Society for Assembly, Handling and Industrial Robotics, Rostock, Germany, 29–30 June 2023, MHI. Accepted.
33. Implicit Methods for Efficient Musculoskeletal Simulation and Optimal Control10.1016/j.piutam.2011.04.027 ↗
34. Real-Time Simulation of Three-Dimensional Shoulder Girdle and Arm Dynamics10.1109/TBME.2014.2309727 ↗
35. Arm Swing in Human Walking: What Is Their Drive?10.1016/j.gaitpost.2014.04.204 ↗
36. Skin Marker-Based Subject-Specific Spinal Alignment Modeling: A Feasibility Study10.1016/j.jbiomech.2022.111102 ↗
37. OpenSim: Simulating Musculoskeletal Dynamics and Neuromuscular Control to Study Human and Animal Movement10.1371/journal.pcbi.1006223 ↗
38. (2025, February 20). TU Delft OpenSim Creator 0.5.14. Available online: https://www.opensimcreator.com/.
39. Evaluation of a Novel Active Exoskeleton for Tasks at or Above Head Level10.1109/LRA.2018.2812905 ↗
40. (2025, February 20). Vicon Motion Systems Limited Plug-In Gait Reference Guide. Available online: https://help.vicon.com/download/attachments/11378719/Plug-in%20Gait%20Reference%20Guide.pdf.
41. MathWorks Inc. (2025, February 21). Csaps. Available online: https://de.mathworks.com/help/curvefit/csaps.html#f7-5467_sep_mw_11ef892b-7c0a-4cb9-a0ba-9331aa87539a.
42. A Model of the Upper Extremity for Simulating Musculoskeletal Surgery and Analyzing Neuromuscular Control10.1007/s10439-005-3320-7 ↗
43. Comparison of Two Methods for Computing Abduction Moment Arms of the Rotator Cuff10.1016/S0021-9290(97)00113-9 ↗
44. Roles of Deltoid and Rotator Cuff Muscles in Shoulder Elevation10.1016/S0268-0033(96)00047-2 ↗
45. A Three-Dimensional Regression Model of the Shoulder Rhythm10.1016/S0268-0033(01)00065-1 ↗
46. Muscle and Tendon: Properties, Models, Scaling, and Application to Biomechanics and Motor Control
47. Hicks, J. (2026, February 19). How Static Optimization Works. Available online: https://opensimconfluence.atlassian.net/wiki/spaces/OpenSim/pages/53089619/How+Static+Optimization+Works.
48. A Validated Open-Source Shoulder Finite Element Model and Investigation of the Effect of Analysis Precision10.1007/s10439-022-03018-8 ↗
49. Active Stability of the Glenohumeral Joint Decreases in the Apprehension Position10.1016/j.clinbiomech.2004.05.008 ↗
50. Development of Recommendations for SEMG Sensors and Sensor Placement Procedures10.1016/S1050-6411(00)00027-4 ↗
51. Feedback Gains for Correcting Small Perturbations to Standing Posture10.1109/9.73565 ↗
52. Integrated EMG and Oxygen Uptake during Dynamic Contractions of Human Muscles10.1152/jappl.1974.36.4.475 ↗
53. Does Enforcing Glenohumeral Joint Stability Matter? A New Rapid Muscle Redundancy Solver Highlights the Importance of Non-Superficial Shoulder Muscles10.1371/journal.pone.0295003 ↗
54. Yan, Z., Yi, H., Du, Z., Huang, T., Han, B., Zhang, L., Peng, A., and Wu, X. (2019, January 6–8). Development of An Assist Upper Limb Exoskeleton For Manual Handling Task. Proceedings of the 2019 IEEE International Conference on Robotics and Biomimetics (ROBIO), Dali, China.10.1109/ROBIO49542.2019.8961609 ↗
55. Between Two Rocks and in a Hard Place: Reflecting on the Biomechanical Basis of Shoulder Occupational Musculoskeletal Disorders10.1177/0018720819896191 ↗