journal article·2026-03-26Open access

T-Connected Line Protection for Hybrid DC Systems Based on the Attenuation Characteristics of Electromagnetic Wave Energy

Yanxia Zhang, Yunfei Wu, Fucheng Li

Applied Sciences· Volume 16· Issue 7

Abstract

T-connected lines are increasingly applied in hybrid DC systems due to their excellent flexibility and scalability. However, their asymmetric boundaries and the unclear physical boundaries at both ends of the LCC-side boundary element pose challenges for relay protection. To address the inability of conventional DC line protection to identify internal and external faults on the LCC side, this paper proposes an identification method based on the attenuation characteristics of electromagnetic wave energy. On this basis, a complete protection scheme for T-connected lines is proposed. The protection is initiated by the rate of voltage change of the T-connected bus; faults inside and outside the T-zone are identified by the direction of the line-mode current on the T-zone outgoing lines; and internal and external faults on the LCC side are identified by the line-mode energy ratio of electromagnetic waves at both ends of the boundary element. Additionally, the fault pole is selected by the electromagnetic wave energy change of the positive and negative poles. A simulation model of a hybrid DC system containing a T-connected line is constructed on PSCAD/EMTDC, and the effectiveness of the method for identifying internal and external faults on the LCC side and the protection scheme are verified.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: HVDC Systems and Fault Protection · Power Systems Fault Detection · High-Voltage Power Transmission Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin 300072, China

Funding

National Natural Science Foundation of China https://ror.org/01h0zpd94

References (27)

Show source-provided references
1. A Pilot Protection Scheme for a Hybrid HVDC Transmission System based on an Approximate Entropy Change Criterion
2. Cai, H., Zhang, J., Yu, J., and Zhang, Z. (2021). Fault Current and Voltage Estimation for Pole-to-Pole Faults in Modular Multilevel Converter Based DC Grids Considering AC Active Power. Appl. Sci., 11.10.3390/app11062882 ↗
3. Research on Single-end Directional Protection for UHV Three-terminal Hybrid DC Transmission Lines Based on T-zone Low and Medium Frequency Attenuation Characteristics as Directional Elements
4. Line Protection Scheme for Hybrid LCC-MMC Type DC Distribution System
5. Wang, M. (2021). Research on Fault Clearing and Recovery Technology of LCC-MMC Hybrid HVDC Transmission System. [Master’s Thesis, Beijing Jiaotong University].
6. Zhang, K. (2019). Research on Fault Analysis and Protection Principles of DC Lines in Multi-Terminal Hybrid HVDC System. [Master’s Thesis, South China University of Technology].
7. Fault Region Identification Method of UHV Three-terminal Hybrid DC Line Based on CNN-SVM
8. Double-ended Protection Scheme for Hybrid DC System Based on EEMD and GP Algorithms
9. Single-ended Protection Scheme for Multi-terminal Hybrid DC Lines Based on Initial Current Traveling Wave Phase
10. Fault Area Discrimination Method for Parallel Multi-terminal Hybrid HVDC Line
11. Protection scheme of multi-terminal hybrid HVDC transmission line based on traveling wave theory and improved Hausdorff distance
12. Single-Ended Protection Scheme for Hybrid Multi-terminal DC Transmission Lines Based on Intrinsic Mode Feature Vector
13. Directional Transient Protection of Multi-terminal Hybrid DC Lines Based on Inherent Mode Energy Entropy
14. Non-Unit Ultra-High-Speed DC Line Protection Method for HVDC Grids Using First Peak Time of Voltage10.1109/TPWRD.2020.3013021 ↗
15. A Pilot Protection Scheme for Hybrid Three-terminal DC Systems
16. Reliability Analysis of Main Electrical Connection for Sending-end Converter Station in Kunliulong Hybrid DC Project of China
17. Li, T. (2022). Research on Fault Location for High Voltage Direct Current Overhead-Cable Hybrid Transmission Lines. [Ph.D. Thesis, Tianjin University].
18. Optimized DC fault transient control strategy for embedded symmetric unipolar LCC-HVDC
19. Li, Y., Zhang, S., He, J., and Li, B. (2025). Mechanism of Commutation Failure and Response Characteristics During Phase Shift Process of LCC Rectifier Station Failure. High Volt. Eng., 1–12.
20. A Pilot Protection Scheme for HVDC Transmission Lines Based on Boundary Energy
21. Optimization Design of FIR Digital Filter Based on Enhanced Multimodal Particle Swarm Optimization Algorithm
22. Single-pole Grounding Fault Identification Method for Photovoltaic Power Station Collection System Based on Pearson Correlation Coefficient
23. Single-pole ground selection method for DC distribution networks based on zero-mode current correlation
24. A New Protection Scheme for Multi-Bus DC Power Systems Using an Event Classification Approach10.1109/TIA.2016.2545639 ↗
25. A Thyristor-Based Multiline Hybrid DCCB in Protection Coordination with MMC in Multiterminal DC Grids10.1109/JESTPE.2024.3447094 ↗
26. Matos Farias, J.V., Camurça, L., Langwasser, M., and Liserre, M. (2022). An Analysis of Combining Dc Circuit Breaker and Hybrid MMC with Reduced Number of FBSM for HVdc System Protection. 2022 IEEE 13th International Symposium on Power Electronics for Distributed Generation Systems (PEDG), IEEE.10.1109/PEDG54999.2022.9923137 ↗
27. Research on transient-based protection for HVDC lines