When Is Electrochemical Sensing Truly Calibration-Free? Principles, Hidden Assumptions, and Analytical Limits
Source abstract
Abstract
Calibration-free electrochemical sensing is increasingly promoted as a route to simpler, more deployable analytical devices. However, the term is used inconsistently, ranging from genuinely absolute measurement to factory-calibrated, ratiometric, self-referenced, drift-corrected or model-assisted operation. This review critically examines what calibration-free sensing can and cannot mean in electrochemical analysis. We argue that a strict claim requires that the reported measurand be obtained from an internally constrained physical, chemical or stoichiometric relationship, with the required parameters known, controlled or independently measured within an uncertainty framework. Potentiometric, amperometric, coulometric, impedimetric, biosensing and affinity-based approaches are compared to show where empirical calibration is removed and where it is shifted to fabrication, internal correction, model fitting, matrix correction or context-specific validation. Particular attention is given to coulometric and thin-layer systems, geometry-constrained devices, electrochemical aptamer-based sensors and self-diagnostic platforms. We propose a classification scheme, a decision tree and a minimum assumption map linking measurand definition, electrochemical signals, signal-to-result relationships, parameter sources, uncertainty, matrix transfer, reproducibility and independent-method agreement. The review provides a practical framework for distinguishing genuinely calibration-free measurements from calibration-reducing, conditionally calibration-free and drift-corrected strategies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical Analysis and Applications · Biosensors and Analytical Detection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Life and Environmental Sciences, Faculty of Science, Engineering & Built Environment, Deakin University, Burwood, VIC 3125, Australia
References (61)
Show source-provided references
1. Electrochemical biosensors: Recommended definitions and classification10.1016/S0956-5663(01)00115-4 ↗
2. Wang, J. (2006). Analytical Electrochemistry, Wiley-VCH. [3rd ed.].10.1002/0471790303 ↗
3. Can calibration-free sensors be realized?10.1021/acssensors.6b00247 ↗
4. Wireless wearable electrochemical sensors: A review10.30744/brjac.2179-3425.RV-62-2020 ↗
5. Campuzano, S., Pedrero, M., Gamella, M., Serafín, V., Yáñez-Sedeño, P., and Pingarrón, J.M. (2020). Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices. Sensors, 20.10.3390/s20123376 ↗
6. Wearable biosensors for healthcare monitoring10.1038/s41587-019-0045-y ↗
7. Real-time measurement of small molecules directly in awake, ambulatory animals10.1073/pnas.1613458114 ↗
8. Thin layer coulometry with ionophore based ion-selective membranes10.1021/ac100524z ↗
9. Sensitivity programmable ratiometric electrochemical aptasensor based on signal engineering for the detection of aflatoxin B1 in peanut10.1016/j.jhazmat.2019.122001 ↗
10. Electrochemical glucose biosensors10.1021/cr068123a ↗
11. Ratiometric electrochemical sensors associated with self-cleaning electrodes for simultaneous detection of adrenaline, serotonin, and tryptophan10.1021/acsami.8b22572 ↗
12. Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations10.1177/1932296815580160 ↗
13. Electrochemical glucose sensors and their applications in diabetes management10.1021/cr068069y ↗
14. (2013). In Vitro Diagnostic Test Systems—Requirements for Blood-Glucose Monitoring Systems for Self-Testing in Managing Diabetes Mellitus (Standard No. ISO 15197:2013).
15. Potentiometric sensors for trace-level analysis10.1016/j.trac.2005.01.003 ↗
16. Mikhelson, K.N. (2013). Ion-Selective Electrodes, Springer.10.1007/978-3-642-36886-8 ↗
17. Bard, A.J., and Faulkner, L.R. (2001). Electrochemical Methods: Fundamentals and Applications, Wiley.
18. Compton, R.G., and Banks, C.E. (2010). Understanding Voltammetry, Imperial College Press. [2nd ed.].10.1142/p726 ↗
19. (2012). Quantifying Uncertainty in Analytical Measurement (Standard No. QUAM:2012.P1).
20. (2008). Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement (Standard No. JCGM 100:2008).
21. Kissinger, P.T., and Heineman, W.R. (1996). Laboratory Techniques in Electroanalytical Chemistry, Marcel Dekker. [2nd ed.].
22. Calibration-free electrochemical biosensors supporting accurate molecular measurements directly in undiluted whole blood10.1021/jacs.7b05412 ↗
23. Single-use electrochemical aptamer-based sensors for calibration-free measurements in human saliva via dual-frequency approaches: Prospects and challenges10.1021/acs.analchem.4c06802 ↗
24. Dual-frequency, ratiometric approaches to EAB sensor interrogation support the calibration-free measurement of specific molecules in vivo10.1021/acssensors.4c00516 ↗
25. Improved calibration of electrochemical aptamer-based sensors10.1038/s41598-022-09070-7 ↗
26. Nanomaterial-mediated self-calibrating biosensors for ultra-precise detection of food hazards: Recent advances and new horizons10.1016/j.ccr.2024.216204 ↗
27. Self-calibrating electrochemical sensors based on uniformly dispersed Ag nanoclusters in nitrogen-doped carbon sheets for determination of nitrite10.1021/acsanm.2c01949 ↗
28. Chen, Y., and Compton, R. (2022). A Calibration-Free pH Sensor Using an In-Situ Modified Ir Electrode for Bespoke Application in Seawater. Sensors, 22.10.3390/s22093286 ↗
29. Calibration-Free Disposable Electrochemical Sensor with Co-Facing Electrodes: Theory and Characterisation with Fixed and Changing Mediator Concentration10.1016/j.electacta.2023.142596 ↗
30. Calibration-free disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples10.1016/j.talanta.2024.127290 ↗
31. Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes10.1016/j.electacta.2011.02.053 ↗
32. Calibration-free potentiometric sensing with solid-contact ion-selective electrodes10.1016/j.trac.2021.116277 ↗
33. Calibration-free ion-selective electrodes: A critical review of design strategies, materials, and applications in sensing10.1016/j.talanta.2025.129261 ↗
34. Terminology of electrochemical methods of analysis (IUPAC Recommendations 2019)10.1515/pac-2018-0109 ↗
35. Eggins, B.R. (2002). Chemical Sensors and Biosensors, John Wiley & Sons Ltd.
36. Fry, C.H., and Langley, S.E.M. (2001). Ion-Selective Electrodes for Biological Systems, Harwood Academic Publishers.10.4324/9780203304747 ↗
37. Cantwell, H. (2025). Eurachem Guide: The Fitness for Purpose of Analytical Methods—A Laboratory Guide to Method Validation and Related Topics, Eurachem.
38. Metrological traceability of measurement results in chemistry: Concepts and implementation (IUPAC Technical Report)10.1351/PAC-REP-07-09-39 ↗
39. Electrochemical aptamer-based sensors for improved therapeutic drug monitoring and high-precision, feedback-controlled drug delivery10.1021/acssensors.9b01616 ↗
40. Switch-based biosensors: A new approach towards real-time, in vivo molecular detection10.1016/j.tibtech.2010.10.005 ↗
41. Macdonald, J.R. (1987). Impedance Spectroscopy: Emphasizing Solid Materials and Systems, Wiley-Interscience.
42. Recent Advances in Voltammetry10.1002/open.201500042 ↗
43. Approaching to Calibration-Free Ion Detection Based on Thin Layer Coulometry with Ultrathin Ion-Selective Membranes10.1021/acsmeasuresciau.4c00069 ↗
44. An all-solid-state thin-layer laminated cell for calibration-free coulometric determination of K+10.1016/j.electacta.2022.139946 ↗
45. Single Voltammetric Sweep Calibration-Free Interrogation of Electrochemical Aptamer-Based Sensors Employing Continuous Square Wave Voltammetry10.1021/acs.analchem.3c05920 ↗
46. Dual-reporter drift correction to enhance the performance of electrochemical aptamer-based sensors in whole blood10.1021/jacs.6b08671 ↗
47. Lowering the detection limit of solvent polymeric ion-selective membrane electrodes. 2. Influence of composition of sample and internal electrolyte solution10.1021/ac9809332 ↗
48. Mruthunjaya, A.K.V., Chatelier, R.C., and Torriero, A.A.J. (2023). Electrochemical Disposable Biosensor to Monitor Dabigatran in Point-of-Care Anticoagulation Therapy. Molecules, 28.10.2139/ssrn.4516211 ↗
49. Calibration-free electrochemical sensor to monitor factor-Xa inhibitors at the point-of-care anticoagulation therapy10.1016/j.talanta.2023.125593 ↗
50. Macdonald, J.R. (2005). Impedance Spectroscopy: Emphasizing Solid Materials and Systems, Wiley-Interscience. [2nd ed.].
51. Folding-based electrochemical biosensors: The case for responsive nucleic acid architectures10.1021/ar900165x ↗
52. Calibration-free measurement of phenylalanine levels in the blood using an electrochemical aptamer-based sensor suitable for point-of-care applications10.1021/acssensors.9b01703 ↗
53. Aptamers-based wearable electrochemical sensors for continuous monitoring of biomarkers in vivo10.1038/s41378-025-00993-5 ↗
54. Statistical Methods For Assessing Agreement Between Two Methods Of Clinical Measurement10.1016/S0140-6736(86)90837-8 ↗
55. Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring10.1002/advs.202411433 ↗
56. A Simultaneous Calibration and Detection Strategy for Electrochemical Sensing with High Accuracy in Complex Water10.1021/acssensors.4c00759 ↗
57. Diamond, D., Relyea, R.A., and McCaul, M. (2023). Understanding and mitigating global change with aquatic sensors: Current challenges and future prospects. Front. Sens., 4.10.3389/fsens.2023.1284043 ↗
58. High frequency, calibration-free molecular measurements in situ in the living body10.1039/C9SC04434E ↗
59. Calibration-Free, Seconds-Resolved In Vivo Molecular Measurements using Fourier-Transform Impedance Spectroscopy Interrogation of Electrochemical Aptamer Sensors10.1021/acssensors.3c00632 ↗
60. Exploring Differential Electron Transfer Kinetics of Electrochemical Aptamer-Based Sensors to Achieve Calibration-Free Measurements10.1021/acssensors.4c02953 ↗
61. Rinn, P., Boruta, F., Czermak, P., and Ebrahimi, M. (2025). Fouling Control of Ion-Selective Electrodes (ISEs) in Aquatic and Aquacultural Environments: A Comprehensive Review. Sensors, 25.10.3390/s25247515 ↗