Biomechanical Evaluation of Loading Variability and Bone Quality in Total Knee Arthroplasty: A Finite Element Sensitivity Study
Source abstract
Abstract
While total knee arthroplasty (TKA) is highly successful, wear, primary fixation stability and structural failure remain significant challenges, particularly in patients with diverse kinetic profiles and compromised bone. This study evaluates a fixed-bearing cruciate-retaining TKA prosthesis under extreme load variability in healthy and osteoporotic bone. Finite element simulations utilized ISO-standardized baseline gait cycle, scaling independently axial forces, antero-posterior forces, and rotational torque to 50% and 200%. Polyethylene insert stress, tibial stress, and bone–implant micromotion were evaluated to assess structural safety, load transfer, and primary stability. Kinetic variability directly influenced the stress magnitude and load transfer. Insert load distribution revealed a compartmental split (medial side bearing 47.6% to 60.9%) sensitive to force orientation and translational load magnitudes (axial and shear), but totally independent of rotational torque magnitude. While reduced bone quality did not significantly affect overall polyethylene stresses, it directly impacted primary stability. Osteoporotic conditions nearly doubled the total baseline interface micromotion (from 19 µm to 37 µm) and exhibited an absolute maximum of 63 µm under 200% axial load scaling. These findings highlight the necessity of definition of model parameters for careful preclinical planning for patients with compromised bone quality regarding prosthesis selection, fixation method and alignment.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, 1050 Bruxelles, Belgium
References (46)
Show source-provided references
1. Varacallo, M., and Johanson, N.A. (2018). Total Knee Arthroplasty (TKA) Techniques, StatPearls Publishing.
2. Cementless Total Knee Arthroplasty: Current Concepts Review10.1302/0301-620X.98B7.37367 ↗
3. Results of Cruciate Retaining Total Knee Arthroplasty10.1097/BCO.0b013e3282f54025 ↗
4. PCL-Retaining versus PCL-Substituting TKR—Outcome Assessment Based on the “Forgotten Joint Score”10.1016/j.jcot.2015.04.009 ↗
5. Is There a Difference Between Posterior-Stabilized, Cruciate-Retaining, or Medial-Pivot Implants Used During Primary Total Knee Arthroplasty?10.1016/j.arth.2024.10.130 ↗
6. (2009). Implants for Surgery. Wear of Total Knee-Joint Prostheses. Loading and Displacement Parameters for Wear-Testing Machines with Displacement Control and Corresponding Environmental Conditions for Test (Standard No. ISO 14243-1:2009).
7. Knee Biomechanics Variability before and after Total Knee Arthroplasty: An Equality of Variance Prospective Study10.1038/s41598-024-52965-w ↗
8. Muscle Force and Movement Variability before and after Total Knee Arthroplasty: A Review10.5312/wjo.v5.i2.69 ↗
9. Sensitivity of Total Knee Replacement Wear to Variability in Motion and Load Input: A Parametric Finite Element Analysis Study10.1002/jor.24755 ↗
10. Loading of the Knee Joint during Activities of Daily Living Measured in Vivo in Five Subjects10.1016/j.jbiomech.2010.03.046 ↗
11. Damage in Total Knee Replacements from Mechanical Overload10.1016/j.jbiomech.2016.05.014 ↗
12. Decreased Stress Shielding with Poly-Ether-Ether-Ketone Tibial Implant for Total Knee Arthroplasty—A Preliminary Study Using Finite Element Analysis10.1016/j.heliyon.2024.e27204 ↗
13. The Relationship between Stress Shielding, Bone Density Changes and Implant Migration, Failure and Fracture after Total Knee Arthroplasty: A Systematic Review10.1002/jeo2.70350 ↗
14. Innocenti, B., Bori, E., Armaroli, F., Schlager, B., Jonas, R., Wilke, H.J., and Galbusera, F. (2022). The Use of Computational Models in Orthopedic Biomechanical Research. Human Orthopaedic Biomechanics: Fundamentals, Devices and Applications, Academic Press.10.1016/B978-0-12-824481-4.00003-2 ↗
15. Biomechanical Analysis of Different Levels of Constraint in TKA during Daily Activities10.1186/s42836-022-00157-0 ↗
16. Increased Varus Deformity Requires Greater Personalisation of Alignment: A Finite Element Biomechanical Study10.1002/jeo2.70482 ↗
17. Ligament-Bone Interaction in a Three-Dimensional Model of the Knee10.1115/1.2894883 ↗
18. Biomechanical Analysis of Augments in Revision Total Knee Arthroplasty10.1115/1.4040966 ↗
19. Structural Properties of Fourth-Generation Composite Femurs and Tibias10.1016/j.jbiomech.2008.08.013 ↗
20. Relations of mechanical properties to density and CT numbers in human bone10.1016/1350-4533(95)97314-F ↗
21. All-Polyethylene Tibial Components Generate Higher Stress and Micromotions than Metal-Backed Tibial Components in Total Knee Arthroplasty10.1007/s00167-015-3630-8 ↗
22. Stemmed TKA in a Femur with a Total Hip Arthroplasty: Is There a Safe Distance between the Stem Tips? J10.1016/j.arth.2013.01.010 ↗
23. Solórzano, W., Ojeda, C., and Lantada, A.D. (2020). Biomechanical Study of Proximal Femur for Designing Stems for Total Hip Replacement. Appl. Sci., 10.10.3390/app10124208 ↗
24. Influence of Ligament Properties on Tibiofemoral Mechanics in Walking10.1055/s-0035-1558858 ↗
25. Comparison between Kinetic and Kinetic-Kinematic Driven Knee Joint Finite Element Models10.1038/s41598-018-35628-5 ↗
26. Luan, Y., Wang, H., Fang, C., Zhang, M., Li, J., Zhang, N., Liu, B., Su, J., and Cheng, C.K. (2023). Mechanical Alignment Tolerance of a Cruciate-Retaining Knee Prosthesis under Gait Loading—A Finite Element Analysis. Front. Bioeng. Biotechnol., 11.10.3389/fbioe.2023.1148914 ↗
27. Okereke, M., and Keates, S. (2018). Finite Element Mesh Generation. Springer Tracts in Mechanical Engineering, Springer.10.1007/978-3-319-67125-3_6 ↗
28. The Biomechanical Effects of Patient Bone Osteoporosis on Tibial Prosthesis Fixation in Total Knee Arthroplasty10.1016/j.medntd.2025.100413 ↗
29. Load-Dependent Characteristics of Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Biomechanical Study10.4055/cios23356 ↗
30. Posterior Stabilized versus Cruciate Retaining Total Knee Arthroplasty Designs: Conformity Affects the Performance Reliability of the Design over the Patient Population10.1016/j.medengphy.2015.01.008 ↗
31. Kurtz, S.M. (2015). UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices, Plastics Design Library.
32. Singh, D.K., and Verma, R.K. (2021). A Critical Review on Ultra High Molecular Weight Polyethylene (UHMWPE) for Prosthesis and Implant Functions. Proceedings of the E3S Web of Conferences, EDP Sciences.10.1051/e3sconf/202130901018 ↗
33. Contribution of Loading Conditions and Material Properties to Stress Shielding near the Tibial Component of Total Knee Replacements10.1016/j.jbiomech.2006.05.020 ↗
34. Relationship of Design Features of Stemmed Tibial Knee Prosthesis with Stress Shielding and End-of-Stem Pain10.1016/j.matdes.2008.06.071 ↗
35. The Influence of Uncemented Femoral Stem Length and Design on Its Primary Stability: A Finite Element Analysis10.1080/10255842.2012.662677 ↗
36. Engh, C.A., O’Connor, D., Jasty, M., McGovern, T.F., Bobyn, J.D., and Harris, W.H. (1992). Quantification of Implant Micromotion, Strain Shielding, and Bone Resorption with Porous-Coated Anatomic Medullary Locking Femoral Prostheses. Proceedings of the Clinical Orthopaedics and Related Research, Lippincott Williams & Wilkins.10.1097/00003086-199212000-00005 ↗
37. Effect of Tibial Tray Backside Design on Stress Transfer and Micromotion in Uncemented Posterior-Stabilized TKA: A Finite Element Study10.1002/jeo2.70608 ↗
38. Unicompartmental Knee Arthroplasty: Survivorship and Risk Factors for Revision: A Population-Based Cohort Study with Minimum 10-Year Follow-Up10.2106/JBJS.21.00346 ↗
39. The Effect of Periprosthetic Bone Loss on the Failure Risk of Tibial Total Knee Arthroplasty10.1002/jor.25642 ↗
40. Computational Modeling of Ligament Mechanics10.1615/CritRevBiomedEng.v29.i3.20 ↗
41. Tibial Implant Fixation in TKA Worth a Revision?—How to Avoid Stress-Shielding Even for Stiff Metallic Implants10.1080/10255842.2020.1830274 ↗
42. A Study on the Effects of Cementless Total Knee Arthroplasty Implants’ Surface Morphology via Finite Element Analysis10.3390/biomedinformatics4020078 ↗
43. Lee, H.H., Hong, H.T., Kim, J.K., Koh, Y.G., Park, K.K., and Kang, K.T. (2025). Optimization of Tibial Stem Geometry in Total Knee Arthroplasty Using Design of Experiments: A Finite Element Analysis. Bioengineering, 12.10.3390/bioengineering12020172 ↗
44. Kinematic Alignment Versus Mechanical Alignment in Total Knee Arthroplasty: A Systematic Review of Mid-Term Functional Outcomes
45. No Difference in 5-Year Clinical or Radiographic Outcomes between Kinematic and Mechanical Alignment in TKA: A Randomized Controlled Trial10.1097/CORR.0000000000001150 ↗
46. No Difference in 10-Year Clinical or Radiographic Outcomes between Kinematic and Mechanical Alignment in TKA: A Randomized Trial10.1097/CORR.0000000000003193 ↗