Evolution of the mechanical properties of Ti-based intermetallic thin films doped with different metals to be used as biomedical devices
Source abstract
Abstract
Abstract This study reports the assessment of the mechanical properties of intermetallic titanium thin films, doped with different amounts of aluminium, copper, silver, and gold, aiming their use as biopotential electrodes for non-invasive physiological monitoring. The four binary thin film systems, Ti-Me (Me = Al, Cu, Ag, Au), were prepared by DC magnetron sputtering, placing different number of Me pellets on a pure Ti target. The use of a Ti-composed target gave rise to a wide range of compositions, resulting in three distinctive zones of (micro)structural features, identified in all the prepared systems. In the first zone, a Ti-rich one, the films behaved like solid solutions, developing Ti-like microstructures. As the Me/Ti atomic ratio increased, the formation of intermetallic phases played the leading role and it became possible to observe two different microstructural trends, clearly related to the Me type. This zone was identified as an intermetallic region. In the third zone, a Me-rich one, the microstructures displayed by the different films (Me/Ti > 1.0) showed to be dependent on the Ti solubility into Me. The assessment of the mechanical properties revealed an improved hardness and stiffness with the Me addition, directly related to the formation of intermetallic compounds in different degrees of crystallinity. Moreover, the adhesive strength between the substrate and the coating was higher for the films deposited in the intermetallic zone, more evident in the films prepared with Au, Cu and Ag, in this order. The hardness enhancement was especially evident for the thin films presenting microstructures typical of thin film metallic glasses (TFMGs), Ti-Au and Ti-Cu, about twice the values exhibited by the Ti-Al and Ti-Ag ones. Furthermore, the toughness of these metallic glass-like thin film systems was remarkable, more evident within the Ti-rich zone, presenting H/E ratios close to 0.1 and good elastic recoveries. In contrast, the typical columnar morphologies, combined with the brittle intermetallic structures of the Ti-Ag and Ti-Al films, proved to be less resistant to the plastic deformation (H/E ≤ 0.04), despite the improved elasticity presented by the Ag-rich films.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · High Entropy Alloys Studies · Electrodeposition and Electroless Coatings
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (78)
Show source-provided references
1. Global Markets for Emerging Medical Device Technologies, 2016.
2. Integrated Circuits and Electrode Interfaces for Noninvasive Physiological Monitoring10.1109/TBME.2014.2308552 ↗
3. Dry-contact and noncontact biopotential electrodes: methodological review10.1109/RBME.2010.2084078 ↗
4. Dry electrodes for electrocardiography10.1088/0967-3334/34/9/R47 ↗
5. Corrosion and surface modification on biocompatible metals: A review10.1016/j.msec.2017.04.102 ↗
6. Electrochemical corrosion characteristics and biocompatibility of nanostructured titanium for implants10.1016/j.apsusc.2017.10.168 ↗
7. Biocompatibility of advanced manufactured titanium implants-A review10.3390/ma7128168 ↗
8. Multifunctional Ti–Me (Me = Al, Cu) thin film systems for biomedical sensing devices10.1016/j.vacuum.2015.05.015 ↗
9. A comparison of gold versus silver electrode contacts for high-resolution gastric electrical mapping using flexible printed circuit board arrays10.1088/0967-3334/32/3/N02 ↗
10. TiAgx thin films for lower limb prosthesis pressure sensors: Effect of composition and structural changes on the electrical and thermal response of the films10.1016/j.apsusc.2013.07.021 ↗
11. Nanostructured functional Ti-Ag electrodes for large deformation sensor applications10.1016/j.sna.2014.09.031 ↗
12. Relationship between nano-architectured Ti1−xCux thin film and electrical resistivity for resistance temperature detectors10.1007/s10853-016-0722-x ↗
13. In vitro evaluation of a γ-TiAl intermetallic for potential endoprothesic applications10.1016/j.intermet.2003.10.004 ↗
14. New developments of ti-based alloys for biomedical applications10.3390/ma7031709 ↗
15. Evolution of the functional properties of titanium-silver thin films for biomedical applications: Influence of in-vacuum annealing10.1016/j.surfcoat.2014.11.020 ↗
16. Study of the electrical behavior of nanostructured Ti–Ag thin films, prepared by Glancing Angle Deposition10.1016/j.matlet.2015.05.067 ↗
17. Wear performance of novel nanostructured Ti-Cu intermetallic alloy as a potential material for biomedical applications10.1016/j.jallcom.2017.01.020 ↗
18. Cytocompatibility and electrochemical properties of Ti–Au alloys for biomedical applications10.1002/jbm.b.30798 ↗
19. High hardness in the biocompatible intermetallic compound -Ti3Au10.1126/sciadv.1600319 ↗
20. Protective Ag:TiO2thin films for pressure sensors in orthopedic prosthesis: The importance of composition, structural and morphological features on the biological response of the coatings10.1007/s10856-014-5251-z ↗
21. Magnetron sputtered Ti–Si–C thin films prepared at low temperatures10.1016/j.surfcoat.2007.01.025 ↗
22. Magnetron sputter deposition: Linking discharge voltage with target properties10.1016/j.tsf.2008.11.108 ↗
23. Influence of the target composition on the discharge voltage during magnetron sputtering10.1016/j.surfcoat.2005.12.047 ↗
24. Energy dependence of the ion-induced sputtering yields of monatomic solids10.1016/0092-640X(84)90016-0 ↗
25. Thin film metallic glasses: Unique properties and potential applications10.1016/j.tsf.2012.03.092 ↗
26. Structure and properties of sputter deposited crystalline and amorphous Cu-Ti films10.1016/j.tsf.2015.10.081 ↗
27. Zr-Cu thin film metallic glasses: An assessment of the thermal stability and phases’ transformation mechanisms10.1016/j.jallcom.2014.08.253 ↗
28. On the effective sputter yield during magnetron sputter deposition10.1016/j.nimb.2014.03.001 ↗
29. The influence of target surface morphology on the deposition flux during direct-current magnetron sputtering10.1016/j.tsf.2012.11.097 ↗
30. Microstructural evolution during film growth10.1116/1.1601610 ↗
31. K. Chang, D. Music, M. to Baben, D. Lange, H. Bolvardi, J.M. Schneider, Modeling of metastable phase formation diagrams for sputtered thin films, Sci. Technol. Adv. Mater. 17 (2016) 210–219. doi:10.1080/14686996.2016.1167572.10.1080/14686996.2016.1167572 ↗
32. Phase formation in co-deposited metallic alloy thin films10.1007/BF01160780 ↗
33. Critical analysis of the Ti-Al phase diagrams, UPB Sci
34. The Ag-Ti (Silver-Titanium) system10.1007/BF02884876 ↗
35. J.J.W. Morris, A Survey of Materials Science I. Structure, University of California, Berkeley, 2007.
36. Dean · 1999
37. Commentary: The materials project: A materials genome approach to accelerating materials innovation10.1063/1.4812323 ↗
38. Formation enthalpies by mixing GGA and GGA + U calculations
39. First-principles investigation of structural, mechanical and electronic properties for Cu–Ti intermetallics10.1016/j.commatsci.2016.06.015 ↗
40. Elastic moduli of cast Ti-Au, Ti-Ag, and Ti-Cu alloys10.1016/j.dental.2005.05.015 ↗
41. Ιntermetallic β-Ti3Au hard thin films prepared by magnetron sputtering10.1016/j.tsf.2017.11.027 ↗
42. Effect of gold addition on the microstructure, mechanical properties and corrosion behavior of Ti alloys10.1007/s13404-014-0138-9 ↗
43. High hardness in the biocompatible intermetallic compound β-Ti3Au10.1126/sciadv.1600319 ↗
44. Thin film metallic glasses: Preparations, properties, and applications10.1007/s11837-010-0053-3 ↗
45. Designing biocompatible Ti-based metallic glasses for implant applications10.1016/j.msec.2012.11.015 ↗
46. Microstructural, thermal and mechanical behavior of co-sputtered binary Zr-Cu thin film metallic glasses10.1016/j.tsf.2013.05.177 ↗
47. The Cu-Ti (Copper-Titanium) system10.1007/BF02880329 ↗
48. The Au-Ti (Gold-Titanium) system10.1007/BF02868667 ↗
49. Thin film metallic glasses in optoelectronic, magnetic, and electronic applications: A recent update10.1016/j.cossms.2015.01.001 ↗
50. Biocompatibility and mechanical property evaluation of Zr-Ti-Fe based ternary thin film metallic glasses10.1016/j.surfcoat.2016.11.039 ↗
51. Thermal stability of nitride thin films10.1016/S0042-207X(00)00143-3 ↗
52. Microstructural design of hard coatings10.1016/j.pmatsci.2006.02.002 ↗
53. Hard nanocomposite coatings: Thermal stability, oxidation resistance and toughness10.1016/j.surfcoat.2012.05.073 ↗
54. Transmission electron microscopy studies and simulation of the indentation response of superelastic fullerenelike carbon nitride thin films10.1063/1.2939716 ↗
55. How hard is fullerene-like CNx? Some observations from the nanoindentation response of a magnetron-sputtered coating
56. On the significance of the H/E ratio in wear control: a nanocomposite coating approach to optimised tribological behaviour10.1016/S0043-1648(00)00488-9 ↗
57. Design criteria for wear-resistant nanostructured and glassy-metal coatings10.1016/j.surfcoat.2003.09.011 ↗
58. Functional behaviour of TiO2 films doped with noble metals
59. Protective over-layer coating preventing cracking of thin films deposited on flexible substrates10.1016/j.surfcoat.2013.12.041 ↗
60. S. V. Ketov, R. Joksimovic, G. Xie, A. Trifonov, K. Kurihara, D. V. Louzguine-Luzgin, Formation of nanostructured metallic glass thin films upon sputtering, Heliyon. 3 (2017) 1–16. doi:10.1016/j.heliyon.2016.e00228.10.1016/j.heliyon.2016.e00228 ↗
61. Fundamental Properties of Intermetallic Compounds10.1557/S0883769400045085 ↗
62. Grindability of dental cast Ti-Ag and Ti-Cu alloys10.4012/dmj.22.191 ↗
63. Microstructure, mechanical properties, bio-corrosion properties and antibacterial properties of Ti-Ag sintered alloys10.1016/j.msec.2016.01.081 ↗
64. Functional behaviour of TiO2 films doped with noble metals10.1179/1743294415Y.0000000085 ↗
65. Mechanical and wear characteristics of a-C:H/Cr/AlN/Ti multilayer films deposited by PVD/PACVD10.1016/j.surfcoat.2016.12.109 ↗
66. A review of experimental approaches to fracture toughness evaluation at the micro-scale10.1016/j.matdes.2019.107762 ↗
67. Size-dependent failure mechanisms in ZrNi thin metallic glass films10.1016/j.scriptamat.2014.06.011 ↗
68. Homogeneous flow and size dependent mechanical behavior in highly ductile Zr65Ni35 metallic glass films10.1016/j.actamat.2017.03.072 ↗
69. Ductility and work hardening in nano-sized metallic glasses
70. Mechanisms of coating failure as demonstrated by scratch and indentation testing of TiN coated HSS
71. Deformation, failure and removal mechanisms of thin film structures in abrasive machining10.1007/s40436-016-0165-2 ↗
72. Sharpness improvement of surgical blade by means of ZrCuAlAgSi metallic glass and metallic glass thin film coating10.1016/j.intermet.2012.06.014 ↗
73. Micro-scratch study of a magnetron-sputtered Zr-based metallic-glass film10.1016/j.surfcoat.2009.05.017 ↗
74. Tribological and mechanical properties of high power laser surface-treated metallic glasses10.1016/j.msea.2007.02.119 ↗
75. Electro-Mechanical Testing of Conductive Materials Used in Flexible Electronics10.3389/fmats.2016.00011 ↗
76. Ductile film delamination from compliant substrates using hard overlayers10.1016/j.tsf.2014.02.093 ↗
77. Film-thickness effect of Ag lubricant layer in the nano-region10.1016/S0043-1648(03)00530-1 ↗
78. Multi-Phase Friction and Wear Reduction by Copper Nanopartices10.3390/lubricants4040036 ↗