Effect of micro shot peening on the mechanical properties and corrosion behavior of two microstructure Ti–6Al–4V alloy
Source abstract
Abstract
Abstract Titanium alloys continue to be used extensively for the fabrication of surgical implants due to their excellent mechanical, physical and biological performance. The surface modification is the main technique to maintain a relatively good mechanical properties and biocompatibility. In this study, a surface modification through micro shot peening (SP) using different ceramic shot (850, 450 and 125–250 μm) at 0.22 mmA have been done on two microstructures Ti–6Al–4V alloy. The effect of this treatment on the corrosion behavior, surface roughness, microhardness profiles, and residual stresses were investigated. In addition, the corrosion behavior of the ultra-fine grain of Ti–6Al–4V materials produced by rotary swaging (RS) deformation has been investigated and compared with the duplex (DU) and globular (GL) microstructures. The corrosion behavior was studied using potentiodynamic polarization and electro impedance spectroscopy techniques. The electrochemical tests were performed in Ringer's solution at 37 °C. The results show that shot peening resulted in near-surface maximum hardness and residual stresses values. Increasing the shot size led to a lower surface roughness and an improved corrosion resistance. However, SP reduces the corrosion resistance compared with the untreated materials. The globular microstructure shows high corrosion rate compared with the duplex and nanostructured materials.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Surface Treatment and Residual Stress · Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (54)
Show source-provided references
1. Material selection in the design of the femoral component of cemented total hip replacements10.1016/S0267-6605(86)80029-4 ↗
2. Material for the replacement of osteoarthritic hip joints
3. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials10.1097/00003086-199201000-00014 ↗
4. In vivo corrosion of 316L stainless-steel hip implants: morphology and elemental compositions of corrosion products10.1016/S0142-9612(97)00208-1 ↗
5. The corrosion scenario in human body: stainless steel 316L orthopaedic implants
6. Titanium alloys for hip joint replacements10.1016/0267-6605(87)90015-1 ↗
7. Contact pressures in the human hip joint measured in vivo10.1073/pnas.83.9.2879 ↗
8. Bergmann · 1998
9. Leyens · 2003 · 1–42 · 454
10. Surface nanocrystallization induced by shot peening and its effect on corrosion resistance of 1Cr18Ni9Ti stainless steel10.1016/j.surfcoat.2005.04.046 ↗
11. Fatigue properties of smooth and as-shot peened N bearing austenitic stainless steel under tension-tension condition
12. Response of MG63 osteoblast-like cells to titanium and titanium alloy is dependent on surface roughness and composition10.1016/S0142-9612(98)00144-6 ↗
13. Innovative surface modification of Ti–6Al–4V alloy with a positive effect on osteoblast proliferation and fatigue performance10.1016/j.msec.2014.03.024 ↗
14. Influence of shot peening on corrosion properties of biocompatible magnesium alloy AZ31 coated by dicalcium phosphate dehydrate (DCPD)10.1016/j.msec.2014.03.023 ↗
15. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
16. Effect of surface roughness of the titanium alloy Ti–6Al–4V on human bone marrow cell response and on protein adsorption10.1016/S0142-9612(00)00274-X ↗
17. Pre-corrosion and surface treatments effects on the fatigue life of AA6082 T610.1002/adem.201300054 ↗
18. The effects of laser peening and shot peening on high cycle fatigue in 7050-T7451 aluminum alloy10.1016/j.msea.2009.08.045 ↗
19. Influence of peening on the corrosion properties of AISI 304 stainless steel10.1016/j.corsci.2009.08.008 ↗
20. Effect of surface mechanical attrition treatment on corrosion behavior of 316 Stainless Steel10.1016/S1006-706X(09)60030-3 ↗
21. Corrosion of implant materials10.1146/annurev.ms.06.080176.001321 ↗
22. Stability, reactivity and breakdown of passive films. Problems of recent and future research10.1016/S0013-4686(00)00347-9 ↗
23. From Bacon to barriers: a review on the passivity of metals and alloys10.1007/s100080100219 ↗
24. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
25. Effect of surface and bulk plastic deformations on the corrosion resistance and corrosion fatigue performance of AISI 316L10.1016/j.surfcoat.2014.10.052 ↗
26. Influence of shot peening on fatigue performance of high-strength aluminum-and magnesium alloys
27. Effect of shot peening on residual stress and stress corrosion cracking for cold worked austenitic stainless steel
28. Study on surface properties and corrosion resistance of 316L stainless steel processed with steel slag ball blasting treatment
29. Properties of passive film formed on CP titanium, Ti–6Al–4V and Ti–13.4Al–29Nb alloys in simulated human body conditions10.1016/j.intermet.2004.10.001 ↗
30. Surface nanocrystallization of 316L stainless steel induced by ultrasonic shot peening10.1016/S0921-5093(00)00686-9 ↗
31. Rajan · 1994 · 305
32. Effect of quenching temperature on the mechanical properties of cast Ti–6Al–4V alloy
33. Influence of processing on microstructure and mechanical properties of (α+β) titanium alloys10.1016/S0921-5093(97)00778-8 ↗
34. The effect of microstructure on the mechanical properties of two-phase titanium alloys10.1016/S0924-0136(02)00248-0 ↗
35. Fatigue strength of work softening layer produced by shot peening
36. Microstructural investigations of the shot peened steel 42 CrMo4 in different heat treatment conditions by the aid of a X-ray profile analysis
37. Simulation for surface self-nanocrystallization under shot peening10.1007/BF02487679 ↗
38. Schulze · 2005
39. Correlation of shot peening parameters to surface characteristic
40. Influence of shot peening parameters on residual stresses in flake and vermicular cast irons
41. Skinner · 1978 · 100
42. An analytical approach to relate shot peening parameters to Almen intensity10.1016/j.surfcoat.2010.08.105 ↗
43. Surface layer properties and fatigue behavior in Al 7075-T73 and Ti–6Al–4V Comparing results after laser peening; shot peening and ball-burnishing10.1108/17579861111135923 ↗
44. Barzoukas · 1990 · 47
45. Donachie · 2000
46. Lutjering · 2007
47. Anodic polarization of titanium and titanium alloys in hydrochloric acid10.1149/1.2411838 ↗
48. Mechanical and electrochemical behavior of nanocrystalline surface of 304 stainless steel10.1016/S0013-4686(02)00365-1 ↗
49. Corrosion behaviour of ultra fine grained titanium in simulated body fluid for implant application
50. Corrosion behaviour of nanocrystalline 304 stainless steel prepared by equal channel angular pressing10.1016/j.corsci.2011.08.049 ↗
51. Electrochemical analysis of separators used in single-chamber, air–cathode microbial fuel cells10.1016/j.electacta.2012.11.004 ↗
52. Electrochemical corrosion behavior of modified MAO film on magnesium alloy AZ31 irradiated by high-intensity pulsed ion beam10.1016/j.surfcoat.2012.06.053 ↗
53. Corrosion assessment of nitric acid grade austenitic stainless steels10.1016/j.corsci.2008.09.038 ↗
54. Baldev Raj, Influence of oxygen ion irradiation on the corrosion aspects of Ti-5% Ta-2% Nb alloy and oxide coated titanium10.1016/j.corsci.2008.03.019 ↗