journal article·2013-11

Corrosion behavior of plasma sprayed hydroxyapatite and hydroxyapatite-silicon oxide coatings on AISI 304 for biomedical application

Gurpreet Singh, Hazoor Singh, Buta Singh Sidhu

Publisher page

Abstract

Abstract The objective of this study is to evaluate corrosion resistance of plasma sprayed hydroxyapatite (HA) and HA silicon oxide (SiO2) coated AISI 304 substrates. In HA SiO2 coatings, 10 wt% SiO2 and 20 wt% SiO2 was mixed with HA. The feedstock and coatings were characterized by X-ray diffraction and scanning electron microscopy/energy dispersive X-ray spectroscopy. The corrosion resistance was determined for the uncoated and coated samples. The corrosion resistance of the AISI 304 was found more after the deposition of the HA SiO2 coatings rather than HA coating and uncoated. All the coatings were crack free after 24 h dipping in Ringer's solution for electrochemical corrosion testing.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Properties of hydroxyapatite-based biomaterials for use as hard tissue replacement implants10.1557/JMR.1998.0015 ↗
2. Initial bone matrix formation at the hydroxyapatite interface in vivo10.1002/jbm.820290113 ↗
3. Mechanisms and Structure of the bond between bone and hydroxyapatite ceramics10.1002/jbm.820270810 ↗
4. Calcium phosphate coatings or medical implants10.1243/0954411981533917 ↗
5. Silica based bioactive glasses modulate expression of bone morphogenetic protein-2 mRNA in Saos-2 osteoblasts in vitro10.1016/S0142-9612(00)00288-X ↗
6. Effect of silicon level on rate, quality and progression of bone healing within silicate substituted porous hydroxyapatite scaffolds10.1016/j.biomaterials.2006.05.039 ↗
7. Dip coated silicon substituted hydroxyapatite films10.1016/j.actbio.2006.05.004 ↗
8. Studies on the relationship of the chemical constituents of blood and cerebrospinal fluid10.1084/jem.42.4.565 ↗
9. Davis · 2003
10. The effect of structural characteristics on the in vitro bioactivity of hydroxyapatite10.1002/jbm.10087 ↗
11. Fretting wear behavior of thermal sprayed hydroxyapatite coating lubricated with bovine albumin10.1016/S0043-1648(98)00340-8 ↗
12. An investigation of the effects of hydroxyapatite coatings on the fixation strength of cortical screws10.1016/j.medengphy.2004.10.006 ↗
13. Characterization of calcium phosphate bioceramic films using ion beam analysis techniques10.1016/S0257-8972(01)01519-5 ↗
14. Osteoclastic resorption of biomimetic calcium phosphate coatings in vitro10.1002/1097-4636(200108)56:2<208::AID-JBM1085>3.0.CO;2-R ↗
15. Tribological study of plasma hydroxyapatite coatings. Bioceramics 1610.4028/www.scientific.net/KEM.254-256.383 ↗
16. In vivo comparison of the osseointegration of vacuum plasma sprayed titanium and hydroxyapatite coated implants10.1002/jbm.a.10508 ↗
17. J. Fernandez, J.M. Guilemany, M. Gaona, High Crystallinity Degree Hydroxyapatite Coatings using HVOF Spraying. in: Lugscheider, E. (Ed.), Conference Proceedings ITSC, May 2–4, 2005, Basel, Switzerland (ISBN 3-87155-793-5) Ed., DVS/IIW/ASMTSS, 2005, pp. 1219–1224.10.31399/asm.cp.itsc2005p1219 ↗
18. A review on calcium phosphate coatings produced using a sputtering process – an alternative to plasma spraying10.1016/j.biomaterials.2004.02.029 ↗
19. Morphological study of hydroxyapatite nanocrystal suspension10.1023/A:1008918110156 ↗
20. Plasma sprayed dioxide coatings for biomedical applications10.1016/j.surfcoat.2003.12.018 ↗
21. Fabrication and characterization of plasma-sprayed HA/SiO2 coatings for biomedical application10.1016/j.jmbbm.2007.04.003 ↗
22. Underlying mechanisms at the bone-biomaterial interface10.1002/jcb.240560310 ↗
23. The cell attachment and morphology of neonatal rat calvarial osteoblasts on the surface of Ti6Al4V and plasma sprayed HA coating: effect of surface roughness and serum contents10.1023/A:1014393815923 ↗
24. Influence of abrasion on the surface characteristics of thermally sprayed hydroxyapatite coatings10.1016/S0142-9612(02)00222-3 ↗
25. Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: a review10.1002/jbm.1056 ↗
26. Effect of hydroxyapatite thickness on metal ion release from Ti6Al4V substrates10.1016/0142-9612(96)89655-4 ↗
27. In vitro corrosion behavior of bioceramic, metallic and bioceramic-metallic, coated stainless steel dental implants10.1016/S0109-5641(02)00029-5 ↗
28. Characterization of electrolytic HA/ZrO2 double layers coatings on Ti-6Al-4V implant alloy10.1016/j.msec.2005.06.050 ↗
29. Titanium scaffolds for osteointegration: mechanical, in vitro and corrosion behavior10.1007/s10856-006-0052-7 ↗
30. Mechanical and histological evaluation of amorphous calcium phosphate and poorly crystallized hydroxyapatite coatings on titanium coatings10.1002/jbm.820270604 ↗
31. In vivo evaluation of plasma sprayed hydroxyapatite coatings having different crystallinity10.1016/S0142-9612(03)00545-3 ↗
32. Nano-mechanical properties of hydroxyapatite coatings with a focus on the single solidified droplet
33. In Vitro and in vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: the effect of coating characteristics10.1002/(SICI)1097-4636(19971205)37:3<335::AID-JBM4>3.0.CO;2-M ↗