journal article·2016-03Open access

Structure, tribocorrosion and biocide characterization of Ca, P and I containing TiO2 coatings developed by plasma electrolytic oxidation

V. Sáenz de Viteri, R. Bayón, A. Igartua, G. Barandika, J. Esteban Moreno, C. Pérez-Jorge Peremarch, M. Martínez Pérez

Abstract

In hip joint implants, in particular in the stems, wear-corrosion effects can accelerate the degradation of the biomaterial. The lack of osseointegration and the risk of contracting implant-associated infections may be other reasons for a premature failure of the implant. In this work, TiO2 coatings have been developed by means of plasma electrolytic oxidation (PEO) technique in order to achieve wear-resistant hard coatings with osseointegration ability and biocide characteristics. During the PEO process, elements that favor cell growth, like Ca and P, were introduced into the coating. With the purpose of providing the coating with antibacterial properties iodine was added like biocide agent. The microstructure and chemical composition of the developed coatings were analyzed in order to see if the surface of the films was suitable for the cell attachment. The effect of wear-corrosion synergy was studied by means of tribocorrosion tests. Finally, the biocide capacity of iodine against Staphylococcus aureus and Staphylococcus epidermidis was analyzed through bacterial adhesion tests. High wear and corrosion resistance was shown in one of the developed coatings. The achieved surface microstructures seem to be appropriate to improve the osseointegration with proper pore size and porosity index. The antibacterial capacity of iodine was confirmed for S. epidermidis.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Hydrothermal fabrication of iodine doped titanium oxide films on Ti substrate
2. The tribological properties of bioceramics coatings produced on Ti6Al4V alloy by plasma electrolytic oxidation10.1016/j.ceramint.2013.09.062 ↗
3. Hydroxyapatite production on ultrafine-grained pure titanium by micro-arc oxidation and hydrothermal treatment10.1016/j.surfcoat.2011.03.032 ↗
4. Surface free energy and bacterial retention to saliva-coated dental implant materials – an in vivo study10.1016/j.colsurfb.2004.08.002 ↗
5. Characterization of oxide films produced by plasma electrolytic oxidation of a Ti-6Al-4V alloy10.1016/S0257-8972(00)00719-2 ↗
6. Tribological, electrochemical and tribo-electrochemical characterization of bare and nitrited Ti6Al4V in simulated body fluid solution10.1016/j.corsci.2011.01.057 ↗
7. Tribo-electrochemical characterization of metallic biomaterials for total joint replacement10.1016/j.actbio.2011.09.034 ↗
8. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
9. Third body effects on friction and wear during fretting of steel contacts10.1016/j.triboint.2011.02.013 ↗
10. In vitro analysis of wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements10.1243/095441103765212659 ↗
11. A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serum10.1016/j.electacta.2004.07.024 ↗
12. Life expectancy of modular Ti6Al4V hip implants: influence of stress and environment10.1016/j.jmbbm.2011.06.018 ↗
13. Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register. Evaluation of 170,413 operations10.3109/17453671003685400 ↗
14. New strategies in the development of antimicrobial coatings: the example of increasing usage of silver and silver nanoparticles10.3390/polym3010340 ↗
15. The basic science of peri-implant bone healing10.4103/0019-5413.77129 ↗
16. Cellular adhesiveness and extracellular substrata10.1016/S0074-7696(08)62241-X ↗
17. Wettability studies of topologically distinct titanium surfaces10.1016/j.colsurfb.2015.03.024 ↗
18. Binding of plasma proteins to titanium dioxide nanotubes with different diameters
19. Effects of surface wettability and contact time on protein adhesion to biomaterial surfaces10.1016/j.biomaterials.2007.03.032 ↗
20. Application Note 17: Influence of Topography and Wettability on Biocompatibility. http://www.biolinscientific.com/zafepress.php?url=%2Fpdf%2FAttension%2FApplication%20Notes%2FAT_AN_17_roughbio.pdf.
21. Antibiotic-eluting medical devices for various applications10.1016/j.jconrel.2008.05.020 ↗
22. Antibacterial surfaces for biomedical devices10.1586/erd.09.36 ↗
23. Temenoff · 2008
24. Balancing osteoblast functions and bacterial adhesion on functionalized titanium surfaces10.1016/j.biomaterials.2012.01.018 ↗
25. Bone and metal: an orthopaedic perspective on osseointegration of metals10.1016/j.actbio.2014.06.004 ↗
26. In vitro cellular response and in vivo primary osteointegration of electrochemically modified titanium10.1016/j.actbio.2009.09.022 ↗
27. Preparation and properties of plasma electrolytic oxidation coating on sandblasted pure titanium by a combination treatment10.1016/j.msec.2014.06.005 ↗
28. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation10.1016/j.biomaterials.2003.09.048 ↗
29. Effects of implants surface coatings and composition on bone integration: a systematic review10.1111/j.1600-0501.2009.01777.x ↗
30. Effect of Ca/P coating resorption and surgical fit on the bone/implant interface10.1002/jbm.820281109 ↗
31. Osteoclastic resorption of Ca-P biomaterials implanted in rabbit bone10.1007/BF01351842 ↗
32. Fabrication of corrosion resistant, bioactive and antibacterial silver substituted hydroxyapatite/titania composite coating on Cp Ti10.1016/j.ceramint.2011.07.065 ↗
33. Doped TiO2 anodic layers of enhanced antibacterial properties10.1016/j.colsurfb.2012.12.051 ↗
34. A new antibacterial titanium-copper sintered alloy: preparation and antibacterial property10.1016/j.msec.2013.06.016 ↗
35. Antibacterial iodine-supported titanium implants10.1016/j.actbio.2010.11.036 ↗
36. Adhesion of staphylococcal and Caco-2 cells on diamond-like carbon polymer hybrid coating10.1002/jbm.a.31643 ↗
37. Bacterial adhesion on biomedical surfaces covered by micrometric silver islands
38. In vitro biological response to the oxide layer in pure titanium formed at different current densities by plasma electrolytic oxidation10.1016/j.apsusc.2014.06.121 ↗
39. Surface characteristics and bioactivity of oxide films formed by anodic spark oxidation on titanium in different electrolytes10.1016/j.jmatprotec.2008.02.055 ↗
40. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO;2-P ↗
41. Structure, corrosion resistance and in vitro bioactivity of Ca and P containing TiO2 coating fabricated on NiTi alloy by plasma electrolytic oxidation10.1016/j.apsusc.2015.08.228 ↗
42. Tailored aluminum oxide layers by bipolar current adjustment in the plasma electrolytic oxidation (PEO) process10.1016/j.surfcoat.2006.09.005 ↗
43. Characterization of AC PEO coatings on magnesium alloys10.1016/j.surfcoat.2009.02.011 ↗
44. Spectroscopic study of electrolytic plasma and discharging behaviour during the plasma electrolytic oxidation (PEO) process10.1088/0022-3727/43/10/105203 ↗
45. Anatase coating improves implant osseointegration in vivo10.1097/scs.0b013e3180a7728f ↗
46. Structural dependence of apatite formation on titania gels in simulated body fluid10.1002/jbm.a.10414 ↗
47. Synthesis, characterization and application of iodine modified titanium oxides in photocatalytical reactions under visible light irradiation10.1016/j.apsusc.2011.12.066 ↗
48. Surface modification of CP-Ti to improve the fretting-corrosion resistance: thermal oxidation vs. anodizing10.1016/j.msec.2010.03.024 ↗
49. A comparison of corrosion, tribocorrosion and electrochemical impedance properties of pure Ti and Ti6Al4V alloy treated by micro-arc oxidation process10.1016/j.apsusc.2014.11.030 ↗
50. 2015
51. Microstructure and wear resistance of oxide coating on Ti-6Al-4V produced by plasma electrolytic oxidation in an inexpensive electrolyte10.1016/j.surfcoat.2011.09.038 ↗
52. Plasma electrolytic oxidation of titanium in a phosphate/silicate electrolyte and tribological performance of the coatings10.1016/j.apsusc.2014.08.037 ↗